Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness†
J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier, J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier
Abstract
Background: Dynamic indices, such as pulse pressure variation (PPV), are inaccurate predictors of fluid responsiveness in mechanically ventilated patients with low tidal volume. This study aimed to test whether changes in continuous cardiac index (CCI), PPV, and stroke volume variation (SVV) after a mini-fluid challenge (100 ml of fluid during 1 min) could predict fluid responsiveness in these patients.
Methods: We prospectively studied 49 critically ill, deeply sedated, and mechanically ventilated patients (tidal volume <8 ml kg(-1) of ideal body weight) without cardiac arrhythmias, in whom a fluid challenge was indicated because of circulatory failure. The CCI, SVV (PiCCO™; Pulsion), and PPV (MP70™; Philips) were measured before and after 100 ml of colloid infusion during 1 min, and then after the additional infusion of 400 ml during 14 min. Responders were defined as subjects with a ≥15% increase in cardiac index (transpulmonary thermodilution) after the full (500 ml) fluid challenge. Areas under the receiver operating characteristic curves (AUCs) and the grey zones were determined for changes in CCI (ΔCCI100), SVV (ΔSVV100), and PPV (ΔPPV100) after 100 ml fluid challenge.
Results: Twenty-two subjects were responders. The ΔCCI100 predicted fluid responsiveness with an AUC of 0.78. The grey zone was large and included 67% of subjects. The ΔSVV100 and ΔPPV100 predicted fluid responsiveness with AUCs of 0.91 and 0.92, respectively. Grey zones were small, including ≤12% of subjects for both indices.
Conclusions: The ΔSVV100 and ΔPPV100 predict fluid responsiveness accurately and better than ΔCCI100 (PiCCO™; Pulsion) in patients with circulatory failure and ventilated with low volumes.
Keywords: cardiac output; fluid therapy; goal-directed therapy; haemodynamics; monitoring; pulse pressure.
© The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Source: PubMed
Prochains essais cliniques
-
NCT07904767Pas encore de recrutement
-
NCT07931924Pas encore de recrutementIncontinence urinaire | Vessie neurogène | Dérivation urinaire | Malignité pelvienne | Carcinome de la vessie urinaire
-
NCT07932964RecrutementAudition normale | Exposition au bruit | Preferred Loudness Level
-
NCT07933419Pas encore de recrutementCarcinome rénal à cellules claires | Cancer des ovaires | Autres tumeurs solides avancées
-
NCT07931144Pas encore de recrutementEntérocolite nécrosante du nouveau-né | Septicémie néonatale tardive
-
NCT07889232Pas encore de recrutementCancer du poumon non à petites cellules métastatique | Cancer-Associated Weight Loss | Elevated Inflammatory Markers
-
NCT07931534Pas encore de recrutementHypertrophie | Amygdalectomie | Obstruction des voies respiratoires supérieure | Chirurgie adénoïdectomie
-
NCT07933536Pas encore de recrutementPsoriasis modéré à sévère
-
NCT07930793RecrutementAnémie aplastique | Hématopoïèse clonale | Thérapie immunosuppressive
-
NCT07933185RecrutementKystes de la mâchoire | Alveolar Bone Defects
-
NCT07932535Pas encore de recrutement
-
NCT07933211Pas encore de recrutement