Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness†
J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier, J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier
Abstract
Background: Dynamic indices, such as pulse pressure variation (PPV), are inaccurate predictors of fluid responsiveness in mechanically ventilated patients with low tidal volume. This study aimed to test whether changes in continuous cardiac index (CCI), PPV, and stroke volume variation (SVV) after a mini-fluid challenge (100 ml of fluid during 1 min) could predict fluid responsiveness in these patients.
Methods: We prospectively studied 49 critically ill, deeply sedated, and mechanically ventilated patients (tidal volume <8 ml kg(-1) of ideal body weight) without cardiac arrhythmias, in whom a fluid challenge was indicated because of circulatory failure. The CCI, SVV (PiCCO™; Pulsion), and PPV (MP70™; Philips) were measured before and after 100 ml of colloid infusion during 1 min, and then after the additional infusion of 400 ml during 14 min. Responders were defined as subjects with a ≥15% increase in cardiac index (transpulmonary thermodilution) after the full (500 ml) fluid challenge. Areas under the receiver operating characteristic curves (AUCs) and the grey zones were determined for changes in CCI (ΔCCI100), SVV (ΔSVV100), and PPV (ΔPPV100) after 100 ml fluid challenge.
Results: Twenty-two subjects were responders. The ΔCCI100 predicted fluid responsiveness with an AUC of 0.78. The grey zone was large and included 67% of subjects. The ΔSVV100 and ΔPPV100 predicted fluid responsiveness with AUCs of 0.91 and 0.92, respectively. Grey zones were small, including ≤12% of subjects for both indices.
Conclusions: The ΔSVV100 and ΔPPV100 predict fluid responsiveness accurately and better than ΔCCI100 (PiCCO™; Pulsion) in patients with circulatory failure and ventilated with low volumes.
Keywords: cardiac output; fluid therapy; goal-directed therapy; haemodynamics; monitoring; pulse pressure.
© The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Source: PubMed
Tulevat kliiniset tutkimukset
-
NCT07904767Ei vielä rekrytointia
-
NCT07931924Ei vielä rekrytointiaVirtsankarkailu | Neurogeeninen virtsarakko | Virtsan poisto | Lantion pahanlaatuisuus | Virtsarakon karsinooma
-
NCT07932964RekrytointiNormaali kuulo | Melualtistus | Preferred Loudness Level
-
NCT07933419Ei vielä rekrytointiaSelkeäsoluinen munuaissolusyöpä | Munasarjasyöpä | Muut pitkälle edenneet kiinteät kasvaimet
-
NCT07931144Ei vielä rekrytointiaVastasyntyneen nekrotisoiva enterokoliitti | Myöhäinen vastasyntyneen sepsis
-
NCT07889232Ei vielä rekrytointiaMetastaattinen ei-pienisoluinen keuhkosyöpä | Cancer-Associated Weight Loss | Elevated Inflammatory Markers
-
NCT07931534Ei vielä rekrytointiaHypertrofia | Nielurisojen poisto | Hengitysteiden tukos ylempi | Adenoidektomia leikkaus
-
NCT07933536Ei vielä rekrytointiaKeskivaikea tai vaikea psoriaasi
-
NCT07930793RekrytointiAplastinen anemia | Klonaalinen hematopoieesi | Immunosuppressiivinen terapia
-
NCT07933185RekrytointiLeuan kystat | Alveolar Bone Defects
-
NCT07932535Ei vielä rekrytointia
-
NCT07933211Ei vielä rekrytointia