此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Plating of Distal Femur Fractures by Far Cortical Locking Using MotionLoc Screws

2013年1月28日 更新者:Michael Bottlang, PhD、Legacy Biomechanics Laboratory

MotionLoc Study: Healing of Distal Femur Fractures Stabilized With a Flexible Plating Construct Using MotionLoc Screws

The objective of this study is to document callus formation and healing of fractures stabilized with locking plates utilizing modern MotionLoc screws that provide controlled axial micro-motion to actively promote fracture healing.

研究概览

地位

完全的

详细说明

Rigid locked plating constructs can suppress fracture healing, particularly at the near cortex adjacent to the plate where interfragmentary motion is minimal. Dynamic fixation with Far Cortical Locking (FCL) screws reduces construct stiffness and induces axial interfragmentary motion to stimulate symmetric callus formation and healing. Two versions of FCL screws are commercially available, but the clinical durability of this novel concept has not been documented to date. This prospective observational study documented our early clinical experience with MotionLoc® FCL screws for stabilization of distal femur fractures to assess their durability and potential complications.

Thirty-two consecutive patients with 33 distal femur fractures (AO/OTA types 33-A and 33-C) were prospectively enrolled at three trauma centers. Fractures were stabilized by plate osteosynthesis with MotionLoc® FCL screws without supplemental bone graft or bone morphogenic proteins. Thirty patients with 31 fractures were available for follow-up until union or revision. Follow-up visits at 6, 12, and 24 weeks comprised functional and radiographic assessment of implant fixation and fracture healing, including computed tomography scans at week 12. The primary endpoint was fracture healing in absence of complications and revision.

There was no incidence of implant breakage or diaphyseal fixation failure. Thirty of 31 fractures healed within 15.6 ± 6.2 weeks, as evident by bridging callus and pain-free load bearing. There were two revisions, one at 5 days post surgery to correct a mal-rotation, and one at 6 months post surgery to revise a non-union. Periosteal callus distribution at week 6 was symmetrical, with similar amounts of callus at the medial cortex (35%) anterior cortex (30%) and posterior cortex (35%). In 23 fractures (74%), callus formation extended to the lateral cortex under the plate.

Absence of hardware and fixation failure suggests that dynamic plating of distal femur fractures with FCL screws provides safe and effective fixation. Moreover, the amount and symmetric distribution of periosteal callus suggests that dynamic fixation with FCL screws may promote increased fracture healing over standard locked plating. However, this hypothesis on the stimulatory effect of dynamic fixation on fracture healing requires investigation in a future randomized control trial.

研究类型

观察性的

注册 (预期的)

33

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Oregon
      • Portland、Oregon、美国、97232
        • Legacy Health System

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

17年 及以上 (孩子、成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

概率样本

研究人群

Distal femur fractures (AO/OTA Type 33A and 33C)

描述

Inclusion Criteria:

  1. Patients with distal femur fracture (AO/OTA Type 33A and 33C)
  2. Patients 17 years of age and over.
  3. Patients able to be operated on by selected surgeons at the participating centers.

Exclusion Criteria:

  1. Pregnancy
  2. Patients who are enrolled in an investigational treatment trial.
  3. Patients who are not expected to survive the follow-up period.
  4. Considered an inappropriate participant by the study physician.
  5. Revision surgery
  6. Patients currently incarcerated or awaiting incarceration.
  7. Severe spinal injury with neurological deficit resulting in paralysis.
  8. Fracture fixed more then 28 days after injury.
  9. Acute or chronic local or systemic infections
  10. Periprosthetic fractures

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
Femur Fractures
Patients with Distal Femur Fractures

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
骨折愈合
大体时间:术后 6、12 和 24 周
骨折愈合在临床上是通过无痛负重的能力来定义的,而在放射学上是通过骨痂形成和桥接来定义的。
术后 6、12 和 24 周

次要结果测量

结果测量
措施说明
大体时间
骨膜骨痂大小
大体时间:术后 6、12、24 周
使用经过验证的计算算法在射线照片的前部、后部和内侧方面评估骨膜骨痂大小。
术后 6、12、24 周
来自 CT 的桥接愈伤组织
大体时间:手术后12周
由 3-D 渲染支持的横截面图像分析,用于检测股骨前部、后部和外侧的骨桥。
手术后12周
固定失败
大体时间:术后24周
根据术后 12 周和 24 周时的对准丢失情况进行评估
术后24周
硬件故障
大体时间:术后 6、12、24 周
螺钉或板材断裂
术后 6、12、24 周

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Michael Bottlang, PhD、Legacy Biomechanics Laboratory
  • 学习椅:Steven Madey, MD、Legacy Health System

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2011年4月1日

初级完成 (实际的)

2012年5月1日

研究完成 (实际的)

2013年1月1日

研究注册日期

首次提交

2012年8月15日

首先提交符合 QC 标准的

2012年8月16日

首次发布 (估计)

2012年8月17日

研究记录更新

最后更新发布 (估计)

2013年1月29日

上次提交的符合 QC 标准的更新

2013年1月28日

最后验证

2013年1月1日

更多信息

与本研究相关的术语

其他研究编号

  • MotionLoc Screw

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅