Rigid locked plating constructs can suppress fracture healing, particularly at the near cortex adjacent to the plate where interfragmentary motion is minimal. Dynamic fixation with Far Cortical Locking (FCL) screws reduces construct stiffness and induces axial interfragmentary motion to stimulate symmetric callus formation and healing. Two versions of FCL screws are commercially available, but the clinical durability of this novel concept has not been documented to date. This prospective observational study documented our early clinical experience with MotionLoc® FCL screws for stabilization of distal femur fractures to assess their durability and potential complications.
Thirty-two consecutive patients with 33 distal femur fractures (AO/OTA types 33-A and 33-C) were prospectively enrolled at three trauma centers. Fractures were stabilized by plate osteosynthesis with MotionLoc® FCL screws without supplemental bone graft or bone morphogenic proteins. Thirty patients with 31 fractures were available for follow-up until union or revision. Follow-up visits at 6, 12, and 24 weeks comprised functional and radiographic assessment of implant fixation and fracture healing, including computed tomography scans at week 12. The primary endpoint was fracture healing in absence of complications and revision.
There was no incidence of implant breakage or diaphyseal fixation failure. Thirty of 31 fractures healed within 15.6 ± 6.2 weeks, as evident by bridging callus and pain-free load bearing. There were two revisions, one at 5 days post surgery to correct a mal-rotation, and one at 6 months post surgery to revise a non-union. Periosteal callus distribution at week 6 was symmetrical, with similar amounts of callus at the medial cortex (35%) anterior cortex (30%) and posterior cortex (35%). In 23 fractures (74%), callus formation extended to the lateral cortex under the plate.
Absence of hardware and fixation failure suggests that dynamic plating of distal femur fractures with FCL screws provides safe and effective fixation. Moreover, the amount and symmetric distribution of periosteal callus suggests that dynamic fixation with FCL screws may promote increased fracture healing over standard locked plating. However, this hypothesis on the stimulatory effect of dynamic fixation on fracture healing requires investigation in a future randomized control trial.
Тип исследования
Регистрация (Ожидаемый)
Контакты и местонахождение
Места учебы
-
-
Oregon
-
Portland, Oregon, Соединенные Штаты, 97232
- Legacy Health System
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Метод выборки
Исследуемая популяция
Описание
Inclusion Criteria:
- Patients with distal femur fracture (AO/OTA Type 33A and 33C)
- Patients 17 years of age and over.
- Patients able to be operated on by selected surgeons at the participating centers.
Exclusion Criteria:
- Pregnancy
- Patients who are enrolled in an investigational treatment trial.
- Patients who are not expected to survive the follow-up period.
- Considered an inappropriate participant by the study physician.
- Revision surgery
- Patients currently incarcerated or awaiting incarceration.
- Severe spinal injury with neurological deficit resulting in paralysis.
- Fracture fixed more then 28 days after injury.
- Acute or chronic local or systemic infections
- Periprosthetic fractures
Учебный план
Как устроено исследование?
Детали дизайна
Когорты и вмешательства
Группа / когорта |
|---|
|
Femur Fractures
Patients with Distal Femur Fractures
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Заживление переломов
Временное ограничение: 6, 12 и 24 недели после операции
|
Заживление перелома определяется клинически по способности безболезненно переносить вес, а рентгенологически - по образованию костной мозоли и мостиков.
|
6, 12 и 24 недели после операции
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Размер периостальной мозоли
Временное ограничение: 6, 12, 24 недели после операции
|
Размер периостальной мозоли оценивается в передней, задней и медиальной частях на рентгенограммах с использованием утвержденного вычислительного алгоритма.
|
6, 12, 24 недели после операции
|
|
Преодоление мозолей после КТ
Временное ограничение: 12 недель после операции
|
Анализ изображения поперечного сечения, поддерживаемый трехмерной визуализацией, для обнаружения костных перемычек в передней, задней и латеральной частях бедренной кости.
|
12 недель после операции
|
|
Ошибка фиксации
Временное ограничение: 24 недели после операции
|
Оценивается с точки зрения потери выравнивания через 12 и 24 недели после операции.
|
24 недели после операции
|
|
Аппаратный сбой
Временное ограничение: 6, 12, 24 недели после операции
|
Поломка винта или пластины
|
6, 12, 24 недели после операции
|
Соавторы и исследователи
Спонсор
Следователи
- Главный следователь: Michael Bottlang, PhD, Legacy Biomechanics Laboratory
- Учебный стул: Steven Madey, MD, Legacy Health System
Публикации и полезные ссылки
Даты записи исследования
Изучение основных дат
Начало исследования
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Оценивать)
Обновления учебных записей
Последнее опубликованное обновление (Оценивать)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- MotionLoc Screw
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .