Rigid locked plating constructs can suppress fracture healing, particularly at the near cortex adjacent to the plate where interfragmentary motion is minimal. Dynamic fixation with Far Cortical Locking (FCL) screws reduces construct stiffness and induces axial interfragmentary motion to stimulate symmetric callus formation and healing. Two versions of FCL screws are commercially available, but the clinical durability of this novel concept has not been documented to date. This prospective observational study documented our early clinical experience with MotionLoc® FCL screws for stabilization of distal femur fractures to assess their durability and potential complications.
Thirty-two consecutive patients with 33 distal femur fractures (AO/OTA types 33-A and 33-C) were prospectively enrolled at three trauma centers. Fractures were stabilized by plate osteosynthesis with MotionLoc® FCL screws without supplemental bone graft or bone morphogenic proteins. Thirty patients with 31 fractures were available for follow-up until union or revision. Follow-up visits at 6, 12, and 24 weeks comprised functional and radiographic assessment of implant fixation and fracture healing, including computed tomography scans at week 12. The primary endpoint was fracture healing in absence of complications and revision.
There was no incidence of implant breakage or diaphyseal fixation failure. Thirty of 31 fractures healed within 15.6 ± 6.2 weeks, as evident by bridging callus and pain-free load bearing. There were two revisions, one at 5 days post surgery to correct a mal-rotation, and one at 6 months post surgery to revise a non-union. Periosteal callus distribution at week 6 was symmetrical, with similar amounts of callus at the medial cortex (35%) anterior cortex (30%) and posterior cortex (35%). In 23 fractures (74%), callus formation extended to the lateral cortex under the plate.
Absence of hardware and fixation failure suggests that dynamic plating of distal femur fractures with FCL screws provides safe and effective fixation. Moreover, the amount and symmetric distribution of periosteal callus suggests that dynamic fixation with FCL screws may promote increased fracture healing over standard locked plating. However, this hypothesis on the stimulatory effect of dynamic fixation on fracture healing requires investigation in a future randomized control trial.
Tipo de estudio
Inscripción (Anticipado)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Oregon
-
Portland, Oregon, Estados Unidos, 97232
- Legacy Health System
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- Patients with distal femur fracture (AO/OTA Type 33A and 33C)
- Patients 17 years of age and over.
- Patients able to be operated on by selected surgeons at the participating centers.
Exclusion Criteria:
- Pregnancy
- Patients who are enrolled in an investigational treatment trial.
- Patients who are not expected to survive the follow-up period.
- Considered an inappropriate participant by the study physician.
- Revision surgery
- Patients currently incarcerated or awaiting incarceration.
- Severe spinal injury with neurological deficit resulting in paralysis.
- Fracture fixed more then 28 days after injury.
- Acute or chronic local or systemic infections
- Periprosthetic fractures
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
|---|
|
Femur Fractures
Patients with Distal Femur Fractures
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Curación de fracturas
Periodo de tiempo: 6, 12 y 24 semanas después de la cirugía
|
La curación de la fractura se define clínicamente por la capacidad de soportar peso sin dolor y radiográficamente por la formación de callos y puentes.
|
6, 12 y 24 semanas después de la cirugía
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Tamaño del callo perióstico
Periodo de tiempo: 6, 12, 24 semanas después de la cirugía
|
El tamaño del callo perióstico se evalúa en los aspectos anterior, posterior y medial en las radiografías utilizando un algoritmo computacional validado.
|
6, 12, 24 semanas después de la cirugía
|
|
Puente Callus de CT
Periodo de tiempo: 12 semanas después de la cirugía
|
Análisis de imágenes transversales, respaldado por renderizado 3D, para detectar puentes óseos en los aspectos anterior, posterior y lateral del fémur.
|
12 semanas después de la cirugía
|
|
Fallo de fijación
Periodo de tiempo: 24 semanas después de la cirugía
|
Evaluado en términos de pérdida de alineación a las 12 y 24 semanas después de la cirugía
|
24 semanas después de la cirugía
|
|
Fallo de hardware
Periodo de tiempo: 6, 12, 24 semanas después de la cirugía
|
Rotura de tornillo o placa
|
6, 12, 24 semanas después de la cirugía
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Michael Bottlang, PhD, Legacy Biomechanics Laboratory
- Silla de estudio: Steven Madey, MD, Legacy Health System
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- MotionLoc Screw
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .