Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Plating of Distal Femur Fractures by Far Cortical Locking Using MotionLoc Screws

28 januari 2013 bijgewerkt door: Michael Bottlang, PhD, Legacy Biomechanics Laboratory

MotionLoc Study: Healing of Distal Femur Fractures Stabilized With a Flexible Plating Construct Using MotionLoc Screws

The objective of this study is to document callus formation and healing of fractures stabilized with locking plates utilizing modern MotionLoc screws that provide controlled axial micro-motion to actively promote fracture healing.

Studie Overzicht

Toestand

Voltooid

Gedetailleerde beschrijving

Rigid locked plating constructs can suppress fracture healing, particularly at the near cortex adjacent to the plate where interfragmentary motion is minimal. Dynamic fixation with Far Cortical Locking (FCL) screws reduces construct stiffness and induces axial interfragmentary motion to stimulate symmetric callus formation and healing. Two versions of FCL screws are commercially available, but the clinical durability of this novel concept has not been documented to date. This prospective observational study documented our early clinical experience with MotionLoc® FCL screws for stabilization of distal femur fractures to assess their durability and potential complications.

Thirty-two consecutive patients with 33 distal femur fractures (AO/OTA types 33-A and 33-C) were prospectively enrolled at three trauma centers. Fractures were stabilized by plate osteosynthesis with MotionLoc® FCL screws without supplemental bone graft or bone morphogenic proteins. Thirty patients with 31 fractures were available for follow-up until union or revision. Follow-up visits at 6, 12, and 24 weeks comprised functional and radiographic assessment of implant fixation and fracture healing, including computed tomography scans at week 12. The primary endpoint was fracture healing in absence of complications and revision.

There was no incidence of implant breakage or diaphyseal fixation failure. Thirty of 31 fractures healed within 15.6 ± 6.2 weeks, as evident by bridging callus and pain-free load bearing. There were two revisions, one at 5 days post surgery to correct a mal-rotation, and one at 6 months post surgery to revise a non-union. Periosteal callus distribution at week 6 was symmetrical, with similar amounts of callus at the medial cortex (35%) anterior cortex (30%) and posterior cortex (35%). In 23 fractures (74%), callus formation extended to the lateral cortex under the plate.

Absence of hardware and fixation failure suggests that dynamic plating of distal femur fractures with FCL screws provides safe and effective fixation. Moreover, the amount and symmetric distribution of periosteal callus suggests that dynamic fixation with FCL screws may promote increased fracture healing over standard locked plating. However, this hypothesis on the stimulatory effect of dynamic fixation on fracture healing requires investigation in a future randomized control trial.

Studietype

Observationeel

Inschrijving (Verwacht)

33

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Oregon
      • Portland, Oregon, Verenigde Staten, 97232
        • Legacy Health System

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

17 jaar en ouder (Kind, Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Bemonsteringsmethode

Kanssteekproef

Studie Bevolking

Distal femur fractures (AO/OTA Type 33A and 33C)

Beschrijving

Inclusion Criteria:

  1. Patients with distal femur fracture (AO/OTA Type 33A and 33C)
  2. Patients 17 years of age and over.
  3. Patients able to be operated on by selected surgeons at the participating centers.

Exclusion Criteria:

  1. Pregnancy
  2. Patients who are enrolled in an investigational treatment trial.
  3. Patients who are not expected to survive the follow-up period.
  4. Considered an inappropriate participant by the study physician.
  5. Revision surgery
  6. Patients currently incarcerated or awaiting incarceration.
  7. Severe spinal injury with neurological deficit resulting in paralysis.
  8. Fracture fixed more then 28 days after injury.
  9. Acute or chronic local or systemic infections
  10. Periprosthetic fractures

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Femur Fractures
Patients with Distal Femur Fractures

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Breuk Genezing
Tijdsspanne: 6, 12 en 24 weken na de operatie
Breukgenezing wordt klinisch gedefinieerd door het vermogen om pijnloos gewicht te dragen, en radiografisch door eeltvorming en overbrugging.
6, 12 en 24 weken na de operatie

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Periosteale callusgrootte
Tijdsspanne: 6, 12, 24 weken na de operatie
Periosteale callusgrootte wordt beoordeeld aan de anterieure, posterieure en mediale aspecten op röntgenfoto's met behulp van een gevalideerd rekenalgoritme.
6, 12, 24 weken na de operatie
Eelt overbruggen vanaf CT
Tijdsspanne: 12 weken na de operatie
Beeldanalyse in dwarsdoorsnede, ondersteund door 3D-weergave, om benige overbruggingen aan de voorste, achterste en laterale aspecten van het dijbeen te detecteren.
12 weken na de operatie
Fixatie mislukt
Tijdsspanne: 24 weken na de operatie
Beoordeeld in termen van verlies van uitlijning 12 en 24 weken na de operatie
24 weken na de operatie
Hardwarestoring
Tijdsspanne: 6, 12, 24 weken na de operatie
Breuk van schroef of plaat
6, 12, 24 weken na de operatie

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Michael Bottlang, PhD, Legacy Biomechanics Laboratory
  • Studie stoel: Steven Madey, MD, Legacy Health System

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start

1 april 2011

Primaire voltooiing (Werkelijk)

1 mei 2012

Studie voltooiing (Werkelijk)

1 januari 2013

Studieregistratiedata

Eerst ingediend

15 augustus 2012

Eerst ingediend dat voldeed aan de QC-criteria

16 augustus 2012

Eerst geplaatst (Schatting)

17 augustus 2012

Updates van studierecords

Laatste update geplaatst (Schatting)

29 januari 2013

Laatste update ingediend die voldeed aan QC-criteria

28 januari 2013

Laatst geverifieerd

1 januari 2013

Meer informatie

Termen gerelateerd aan deze studie

Aanvullende relevante MeSH-voorwaarden

Andere studie-ID-nummers

  • MotionLoc Screw

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren