此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Effects of GlucoClear CGM System on the Performance of Insulin Therapy in Critically Ill Patients (GlucoClearIT)

2017年3月9日 更新者:Erasme University Hospital

A Study on the Effects of the Use of GlucoClear CGM System on the Performance of Insulin Therapy in Critically Ill Patients

After providing written informed consent, the first 20 Subjects meeting Inclusion/Exclusion Criteria will be consecutively enrolled in the Standard of Care cohort. The moderate treatment cohort will then be consecutively enrolled, followed by the tight glycemic control cohort.

After sensor insertion, baseline evaluations including APACHE II, SOFA, and laboratory evaluations will be determined.

Subjects enrolled in the standard of care cohort will be treated according to the institution's protocol for measuring glucose and managing insulin. These subjects will be monitored on a GlucoClear System but they will not be managed based on the values or trends of the GlucoClear system.

Subjects enrolled in the treatment cohorts will be monitored and managed with a special version of the GlucoClear continuous monitoring system. This system contains the GlucoClear Insulin Dosing Algorithm providing insulin dosing recommendations to enable the clinician to manage patient glucose within pre-specified target levels. These recommendations are presented on screen for a clinical professional to approve or override.

Subjects in the moderate treatment cohort will have their glucose managed in the range of 120 - 180 mg/dl. Subjects in the tight glycemic control treatment cohort will be managed in the range of 80 - 120 mg/dl.

After discharge from the ICU, subjects will followed for adverse events and mortality at 30 days, either by telephone contact or office visit.

研究概览

详细说明

Hyperglycemia, hypoglycemia and glycemic variability, the three components of dysglycemia are independently associated with morbidity and mortality of critically ill patients. Blood glucose (BG) control with insulin has the potential to decrease morbidity and mortality of intensive care unit (ICU) patients. Blood glucose control with insulin, however, is associated with an increased risk of hypoglycemia and its effect on glycemic variability is uncertain. BG control with insulin utilizing manual systems for glucose measurement is blood-consuming and time-consuming, since frequent blood draws for glucose measurements are necessary in order to achieve blood glucose control.

Severe hypoglycemia (blood glucose level < 40 mg/dl) is a feared complication of blood glucose control with insulin. Undoubtedly, with implementation of blood glucose with insulin the incidence of hypoglycemia increases. Reported incidences of severe hypoglycemia rise by 5 to 10-fold as compared to conventional glucose control strategies in randomized controlled trials. Several reports showed a significant association between hypoglycemia and patient outcomes. Recently, an association has even been suggested between moderate and mild hypoglycemia (blood glucose level between 40-69 mg/dL) and patient outcomes. Incidences of moderate hypoglycemia are more prevalent than severe hypoglycemia. The risk of developing (severe or moderate) hypoglycemia hampers, at least in part, broad implementation of blood glucose control with insulin, in particular when aiming at normal blood glucose levels [17,18].

Recent studies showed also significant associations between glycemic variability and patient outcomes. BG control algorithms, if properly applied, could decrease glycemic variability. Experimentally, rodent experiment showed that brain damage was not associated with the duration of severe hypoglycemia, but instead with its correction (mainly overcorrection) with intravenous dextrose causing formation of radicals. Hence, a close glucose monitoring to prevent overcorrection is mandatory.

These different arguments strongly support the need for reliable and accurate CGM. The GlucoClearTM Continuous Glucose Monitoring system from Edwards Lifesciences measures blood sugar by Glucose Oxidase Sensing Technology through in-blood measurement. Blood is automatically drawn and analyzed every 5 minutes from a peripheral venous catheter, with real time graphical display. Blood is then returned to the patient and the system automatically self-calibrates. The GlucoClear CGM is designed to be highly accurate. In a recent study performed in critically ill patients, it was shown to comply with the required standards of quality.

The main research question addressed by the present study is: "To which extent a CGM-guided strategy improve the quality of BG control performance"?

研究类型

介入性

注册 (实际的)

100

阶段

  • 不适用

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Have an anticipated ICU stay of at least 48 hours;
  • Participate or have authorized representative participate in the Informed Consent process and sign/date the approved informed consent form.
  • Have an expected ICU stay of ≥ 24 hours up to 72 hours
  • Have an APACHE II score of ≥ 10, within the first 24 hours of ICU admission.
  • Not be participating in any other investigational interventional study.
  • Have hyperglycemia (BG > 150 mg/dl) up to 6 hours after admission and / or ongoing insulin therapy.
  • Access to a large peripheral vein

Exclusion Criteria:

  • End stage pre-existing medical conditions that would preclude the subject from being able to complete up to 72 hours of glucose monitoring and follow up (14 ± 3 days after Sensor removal); Restricted peripheral venous access, inadequate access for reference sampling or any contraindication to the placement of peripheral IV catheters.
  • Skin conditions or existing (or planned) medical instrumentation and/or dressings that preclude placing the peripheral IV catheters or dressings (e.g., extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis, or surgical dressings).
  • A known history of heparin-induced thrombocytopenia or any contraindication for anti-coagulation therapy.
  • Intolerance to Lactated Ringer's solution ((mEq/liter): Sodium 130; Potassium 4; Calcium 3; Chloride 110; Lactate 28).
  • A positive pregnancy test 72 hours prior to Sensor insertion (for subjects of child bearing potential).
  • Any condition that, in the opinion of the Investigator, would interfere with their participation in the Study.
  • Participated in any other drug, device, or biologic Study within the last 30 days (prior to Sensor insertion) which may clinically interfere with this Study or have not completed the required Protocol follow-up period.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
其他:Continuous monitoring-guided therapy
Healthcare providers were allowed to use the blood glucose values displayed on the intravascular continuous monitoring to adapt insulin therapy
Bedside usual insulin therapy guided by continuous glucose monitoring
其他:Standard of care
Healthcare providers used the usual intermittent method to adapt insulin therapy; the blood glucose values measured by the intravascular continuous monitoring were not displayed but recorded. Usual care involves the adjustment of insulin infusion based on BG values measured with a blood gas analyser 4-6 times per day.
Bedside usual insulin therapy guided by intemittent glucose monitoring

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Time in target
大体时间:72 hours
Cumulative time in target band (expressed in percentage) will be calculated from the set of BG values recorded by the CGM in both groups.
72 hours

次要结果测量

结果测量
措施说明
大体时间
SOFA评分
大体时间:72小时
72小时
Hypoglycaemic index
大体时间:72 hours
Area under the low limit of the target range
72 hours
Glycemic variability
大体时间:72 hours
Coefficient of variation
72 hours
Mortality
大体时间:28 days
ICU, hospital and 28-day mortality
28 days
Length of stay
大体时间:28 days
28 days
Time to target
大体时间:72 hours
Time to achieve the upper limit of target range (hours)
72 hours

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Jean-Louis Vincent, MD PhD、Erasme University Hospital

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2014年5月1日

初级完成 (实际的)

2014年5月1日

研究完成 (实际的)

2015年6月1日

研究注册日期

首次提交

2016年10月3日

首先提交符合 QC 标准的

2017年2月8日

首次发布 (估计)

2017年2月9日

研究记录更新

最后更新发布 (实际的)

2017年3月13日

上次提交的符合 QC 标准的更新

2017年3月9日

最后验证

2017年2月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • P2014/162 / B406201420742

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

Intravascular continuous monitoring的临床试验

3
订阅