Comparing Two Forms of Head Immobilization for Stereotactic Radiotherapy
A Randomized Trial Comparing Two Forms of Immobilization of the Head for Fractioned Stereotactic Radiotherapy
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
PRIMARY OBJECTIVE:
1) To compare the efficacy of two commonly used, generally accepted forms of immobilization for the treatment of lesions in the head with fractionated stereotactic radiotherapy. Specifically, this study will use the ExacTRAC kilovoltage imaging system to assess positioning accuracy for these two systems.
OUTLINE:
Two routinely used methods of immobilization, which differ in their approach to reproduce head position from day-to-day are the Gill-Thomas-Cosman (GTC)frame and the BrainLab thermoplastic mask. The GTC frame fixates on the patient upper detention and thus us in direct mechanical contact with the cranium. The BrainLab mask is a two-part masking system custom-fitted to the front and back of the participant's head. After patients sign an IRB-approved informed consent form, eligible participants are either randomized to either the GTC frame or the mask for their course of SRT. Participants are treated as per standard procedure; however, prior to each treatment, a set of digital kV images (ExacTrac, BrainLabAB, Germany) is taken. These images are fused with reference digitally constructed radiographs obtained from treatment planning CT to yield lateral, longitudinal, and vertical deviations of isocenter and head rotations about respective axes. The primary endpoint of the study is to compare the two systems with respect to mean and standard deviations (SDs) using the distance to isocenter measure.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 3
Contacts and Locations
Study Locations
-
-
Pennsylvania
-
Philadelphia, Pennsylvania, United States, 19107
- Thomas Jefferson University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients who are eligible for fractionated stereotactic radiotherapy
Exclusion Criteria:
- Severe claustrophobia
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: GTC Frame
Participant undergoes SRT using a GTC frame to immobilize the participant's heading during radiation therapy
|
Other Names:
|
|
Experimental: BrainLab thermoplastic mask
Participant undergoes SRT using the BrainLab thermoplastic mask to immobilize the participant's head during radiation therapy
|
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Distance From Ideal to Center of GTC Frame and BrainLab Thermoplastic Mask With Respect to Average and Variability
Time Frame: Measurements taken during SRT
|
This study uses the ExacTRAC imaging system to assess positioning of frame or mask during SRT.
Images yield lateral, longitudinal, and vertical deviations of the isocenter as well as head rotations about respective axes.
|
Measurements taken during SRT
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Shiu A, Parker B, Ye JS, Lii J. An integrated treatment delivery system for CSRS and CSRT and clinical applications. J Appl Clin Med Phys. 2003 Autumn;4(4):261-73. doi: 10.1120/jacmp.v4i4.2496.
- Burton KE, Thomas SJ, Whitney D, Routsis DS, Benson RJ, Burnet NG. Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet. Clin Oncol (R Coll Radiol). 2002 Feb;14(1):31-9. doi: 10.1053/clon.2001.0001.
- Lopatta E, Liesenfeld SM, Bank P, Wurm R, Gunther R, Wiezorek T, Wendt TG. [Improved patient repositioning accuracy by integrating an additional jaw fixation into a high precision face mask system in stereotactic radiotherapy of the head]. Strahlenther Onkol. 2003 Aug;179(8):571-5. doi: 10.1007/s00066-003-0941-3. German.
Helpful Links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 04U.534
- 2004-72 (Other Identifier: CCRRC)
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.