Bubble Continuous Positive Airway Pressure (CPAP) With Conventional CPAP for Extubation in Preterm Infants
Bubble CPAP vs. Conventional CPAP Following Extubation in Preterm Very Low Birth Weight (VLBW) Infants: A Randomized Controlled Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Delhi
-
New Delhi, Delhi, India
- All India Institute of Medical Sciences
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Gestation less than 32 weeks
- Birth weight less than 1500 g
- Age less than seven days
- First extubation attempt.
Exclusion Criteria:
- A neonate having any of the following will be excluded from the study-
- Severe birth asphyxia defined as need for chest compression for more than 30 seconds
- Suspected congenital neuromuscular disorder
- Major congenital malformation
- Grade 3/4 interventricular haemorrhage
- Hydrops.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Bubble CPAP
All neonates randomised to bubble CPAP will be put on Bubble CPAP following initial extubation in first week of life.
|
Bubble CPAP will be delivered using Fischer & Paykel CPAP system with a starting flow of 6 liters/minute.
CPAP will be initially started at a pressure of 5 - 6 cm H2O and fraction of inspired oxygen (FiO2) of 0.4 - 0.5.
which will be adjusted to maintain oxygen saturation (SpO2) between 87 and 93%.
Other Names:
|
|
Other: Conventional CPAP
All neonates randomly allocated to conventional/ventilator derived CPAP.
|
Conventional CPAP will be delivered using Argyle CPAP (Sherwood Medical Company, Mexico) short nasal prongs with warm, humidified gas used (34-37°C) through a thermo-statically controlled humidifier, flow @ 4-8 L/min from either SLE 2000 pressure-controlled continuous flow ventilator (Specialized Laboratory Equipment, UK) or Baby log 8000 volume guarantee ventilator.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Extubation failure - defined as need for reintubation and mechanical ventilation for any reason within 72 hours of initial extubation
Time Frame: Till 72 hours after extubation
|
Till 72 hours after extubation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Time to extubation failure in hours.
Time Frame: till extubation failure within first 72 hours after extubation
|
till extubation failure within first 72 hours after extubation
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Vinod K Paul, MD PhD, Department of Pediatrics, All India Institute of Medical Sciences, New Delhi
- Principal Investigator: Sucheta Yadav, MBBS, Department of Pediatrics, All India Institute of Medical Sciences, New Delhi
- Study Chair: Mari J Sankar, MD, DM, Department of Pediatrics, All India Institute of Medical Sciences, New Delhi
- Study Chair: Ramesh Agarwal, MD, DM, Department of Pediatrics, All India Institute of Medical Sciences, New Delhi
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- A-74
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Extubation Failure
-
NCT07324382Not yet recruitingAirway Extubation | Extubation Failure | Weaning Mechanical Ventilation
-
NCT05550259Not yet recruitingExtubation Failure
-
NCT07577453Not yet recruitingPostoperative Respiratory Complications | Extubation Failure | Extubation Success
-
NCT07324460Not yet recruitingAirway Extubation | Extubation Failure | Weaning Mechanical Ventilation
-
NCT07630766Completed
-
NCT02911506CompletedSleep Quality | Extubation Failure
-
NCT07038291CompletedExtubation Failure | Ventilated Patients
-
NCT03335345CompletedNon-inferiority, in Terms of Extubation Failure, Continuation of Enteral Nutrition Before Extubation Versus Gastric Vacuity Peri-extubation
-
NCT00977002UnknownExtubation Failure | Acute Respiratory Failure Post Extubation
Clinical Trials on Bubble CPAP
-
NCT02392806CompletedRespiratory Distress Syndrome
-
NCT03944551Terminated
-
NCT04401696CompletedNeonatal Respiratory Distress
-
NCT06038565WithdrawnRespiratory Distress Syndrome | Prematurity
-
NCT03870243Completed
-
NCT00187434UnknownPremature Birth | Respiratory Insufficiency
-
NCT03085329Unknown
-
NCT07162285Enrolling by invitationRespiratory Distress Syndrome, Newborn