Microelectrode Brain-Machine Interface for Individuals With Tetraplegia
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Pennsylvania
-
Pittsburgh, Pennsylvania, United States, 15213
- University of Pittsburgh
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Limited or no ability to use both hands due to cervical spinal cord injury or brainstem or spinal stroke
- At least 1 year post-injury
- Live within 1 hour of the University of Pittsburgh and be willing to travel to the University of Pittsburgh once per week for BMI training
- Additional inclusion criteria must also be reviewed
Exclusion Criteria:
- Certain implanted devices
- Presence of other serious disease or disorder that could affect ability to participate in this study
- Individuals who are immunosuppressed or who have conditions that typically result in immunocompromise
- Additional exclusion criteria must also be reviewed
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Brain-Machine Interface Users
All participants enrolled in the study will undergo Implantation of NeuroPort Arrays in the motor cortex.
There is no control group.
|
Two Blackrock Microsystems NeuroPort Arrays will be implanted in the motor cortex of study participants.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Participants With Successful Implant
Time Frame: One year following array implantation
|
Number of participants who were implanted for at least one year without having to explant the device for safety reasons.
|
One year following array implantation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
7 Degree-of-freedom Movement by Neural Control
Time Frame: One year following array implantation
|
A modified Action Research Arm Test (ARAT) assessment for upper extremity performance was conducted to evaluate neural control of movement of a robotic prosthetic arm with 7 independent degrees of freedom controlled simultaneously.
The degrees of freedom included: 3D translation of arm, 3D orientation of wrist, and 1D open/closing of hand.
The participant used a brain-controlled robotic hand to do 9 tasks (out of 19).
Each test item was timed and scored as 0 (no movement), 1 (task partly done), 2 (task done, but not correctly), or 3 (task done correctly).
Movements that required more than 5 s to complete were scored as 2. The participant attempted each assessment three times and the best score was included.
The total possible score ranged from 0 to 27 (i.e., max possible score of 3 each for 9 total tasks).
A higher score indicates a better outcome.
|
One year following array implantation
|
|
10 Degree-of-freedom Movement by Neural Control
Time Frame: One year following array implantation
|
A modified ARAT was conducted to assess neural control of movement of a robotic prosthetic arm with 10 independent degrees of freedom, controlled simultaneously.
Degrees of freedom included: 3D translation of arm, 3D orientation of wrist, and 4 degrees dictating hand shape, including pinch (flexion of thumb, index and middle fingers), scoop (flexion of ring and pinky fingers), finger abduction (of index, ring and little fingers), and thumb opposition.
The participant used a brain-controlled robotic hand to do 9 tasks (out of 19).
Test items were timed and scored as 0 (no movement), 1 (task partly done), 2 (task done, but not correctly), or 3 (task done correctly).
Movements that required more than 5 s to complete were scored as 2. The participant attempted each assessment three times and the best score was included.
The total possible score ranged from 0 to 27 (i.e., max possible score of 3 each for 9 total tasks).
A higher score indicates a better outcome.
|
One year following array implantation
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Michael L Boninger, MD, University of Pittsburgh
Publications and helpful links
General Publications
- Sponheim C, Papadourakis V, Collinger JL, Downey J, Weiss J, Pentousi L, Elliott K, Hatsopoulos NG. Longevity and reliability of chronic unit recordings using the Utah, intracortical multi-electrode arrays. J Neural Eng. 2021 Dec 28;18(6):10.1088/1741-2552/ac3eaf. doi: 10.1088/1741-2552/ac3eaf.
- Downey JE, Quick KM, Schwed N, Weiss JM, Wittenberg GF, Boninger ML, Collinger JL. The Motor Cortex Has Independent Representations for Ipsilateral and Contralateral Arm Movements But Correlated Representations for Grasping. Cereb Cortex. 2020 Sep 3;30(10):5400-5409. doi: 10.1093/cercor/bhaa120.
- Downey JE, Schwed N, Chase SM, Schwartz AB, Collinger JL. Intracortical recording stability in human brain-computer interface users. J Neural Eng. 2018 Aug;15(4):046016. doi: 10.1088/1741-2552/aab7a0. Epub 2018 Mar 19.
- Downey JE, Brane L, Gaunt RA, Tyler-Kabara EC, Boninger ML, Collinger JL. Motor cortical activity changes during neuroprosthetic-controlled object interaction. Sci Rep. 2017 Dec 5;7(1):16947. doi: 10.1038/s41598-017-17222-3.
- Downey JE, Weiss JM, Muelling K, Venkatraman A, Valois JS, Hebert M, Bagnell JA, Schwartz AB, Collinger JL. Blending of brain-machine interface and vision-guided autonomous robotics improves neuroprosthetic arm performance during grasping. J Neuroeng Rehabil. 2016 Mar 18;13:28. doi: 10.1186/s12984-016-0134-9.
- Wodlinger B, Downey JE, Tyler-Kabara EC, Schwartz AB, Boninger ML, Collinger JL. Ten-dimensional anthropomorphic arm control in a human brain-machine interface: difficulties, solutions, and limitations. J Neural Eng. 2015 Feb;12(1):016011. doi: 10.1088/1741-2560/12/1/016011. Epub 2014 Dec 16.
- Collinger JL, Wodlinger B, Downey JE, Wang W, Tyler-Kabara EC, Weber DJ, McMorland AJ, Velliste M, Boninger ML, Schwartz AB. High-performance neuroprosthetic control by an individual with tetraplegia. Lancet. 2013 Feb 16;381(9866):557-64. doi: 10.1016/S0140-6736(12)61816-9. Epub 2012 Dec 17.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- STUDY19030235
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Access Criteria
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
- SAP
- ICF
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.