Safety & Efficacy of Subretinal Implants for Partial Restoration of Vision in Blind Patients
Safety & Efficacy of Subretinal Implants for Partial Restoration of Vision in Blind Patients: A Prospective Mono- & Multicenter Clinical Study Based on Randomized Intra-individual Implant Activation in Degenerative Retinal Disease Patients.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Cyberport
-
Hong Kong, Cyberport, Hong Kong, 100
- Ophthalmology Eye Institute, University of Hong Kong
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Hereditary retinal degeneration of the outer retinal layers i.e. photoreceptor rods & cones.
- Pseudophakia
- Angiography shows retinal vessels adequately perfused, despite pathological RP condition.
- Age between 18 and 78 years.
- Blindness (at least monocular) i.e. visual functions not appropriate for localization of objects, self sustained navigation and orientation (impaired light localization or worse).
- Ability to read normal print in earlier life, optically corrected without magnifying glass.
- Willing and able to give written informed consent in accordance to EN ISO 14155 (section 6.7) and local legislation prior to participation in the study. Able to perform the study during the full time period of one year
Exclusion Criteria:
- Period of appropriate visual functions < 12 years / lifetime.
- Optical Coherence Tomography (OCT) shows significant retina edema &/or scar tissue within target region for implant.
- Retina detected as too thin to expect required rest-functionality of inner retina as shown via Optical Coherence Tomography (OCT).
- Lack of inner-retinal function, as determined by Electrically Evoked Phosphenes (EEP).
- Heavy clumped pigmentation at posterior pole
- Any other ophthalmologic disease with relevant effect upon visual function (e.g. glaucoma, optic neuropathies, trauma, diabetic retinopathy, retinal detachment).
- Amblyopia reported earlier in life on eye to be implanted
- Systemic diseases that might imply considerable risks with regard to the surgical interventions and anaesthesia (e.g. cardiovascular/ pulmonary diseases, severe metabolic diseases).
- Neurological and/or psychiatric diseases (e.g. M. Parkinson, epilepsy, depression).
- Hyperthyroidism or hypersensitivity to iodine
- Women who are pregnant or nursing, or women of childbearing potential who are not willing to use a medically acceptable means of birth control for the duration of the study, or women unwilling to perform a pregnancy test before entering the study.
- Participation in another interventional clinical trial within the past 30 days.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Single Group Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: intra-individual implant ON
intra-individual implant activation
|
surgical implantation of subretinal device
Other Names:
intra-individual implant OFF
Other Names:
|
|
Placebo Comparator: intra-individual implant OFF
intra-individual implant deactivation
|
surgical implantation of subretinal device
Other Names:
intra-individual implant OFF
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Safety
Time Frame: 1 year
|
treatment shows no permanent damage of function and structures that have been functional before surgery and no permanent damage to health and/or well being of patients
|
1 year
|
|
Efficacy
Time Frame: 1 year
|
Activities of Daily Living & Mobility are significantly improved with implant-ON versus OFF, as shown via tests:
|
1 year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Safety
Time Frame: 1 year
|
Patient long term safety:
|
1 year
|
|
Efficacy
Time Frame: 1 year
|
Visual Acuity / Light-perception and/or Object-recognition are significantly improved with implant-ON versus OFF as shown via:
|
1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: David Wong, Prof., MD, Chair Professor in Ophthalmology Eye Institute
Publications and helpful links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- HKCTR-1198
- RI-MC-CT-2009 (Clinicaltrials.gov)
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.