Evaluation of a Combined Near Infrared Spectroscopy (NIRS) and Intravascular Ultrasound (IVUS) Catheter for Detection of Lipid Rich Plaque
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The aims of this study are to:
- Test the ability of the new NIRS IVUS system to detect lipid pool
- Evaluate the accuracy of the NIRS IVUS system for localization of lipide rich plaque: superficial vs deep
- Improve diagnostic accuracy of OCT for detection of lipid using information from NIRS IVUS
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
Massachusetts
-
Boston, Massachusetts, United States, 02114
- Massachusetts General Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
Patient Characteristics
- Males and non-pregnant females > 18 and < 79 years of age
- Patients referred for diagnostic coronary angiography who are found to have lesions in native coronary arteries which will be treated by percutaneous coronary intervention (PCI) (or patients with known coronary lesions who are referred for planned PCI)
- Able to give written informed consent
Lesion Characteristics
- Lesion in native coronary artery
- Angiographic stenosis > 50%
- Reference vessel diameter 2.5 mm - 4.0 mm by visual estimation
- Subjects who have successful PCI and OCT
General Exclusion Criteria
- Subjects who are unable or unwilling to sign the informed consent form
- Subjects with serious co-morbid conditions that in judgment of the investigator preclude inclusion in this study (such as terminal cancer, life expectancy < 6 months, Liver Function Tests (LFTs) > 3 times Upper Limit of Normal (ULN), or post-transplant)
- Subjects with New York Heart Association (NYHA) class III or IV heart failure or known left ventricular ejection fraction < 30%
- Subjects who have experienced an ST-elevation myocardial infarction (STEMI) within 72 hours prior to the procedure
- Subjects with hemodynamic or electrical instability (including shock)
- Subjects diagnosed with severe, non-catheter-related coronary artery spasm
- Subjects who are or may be pregnant
- Subjects with known allergies to contrast media
- Subjects with renal failure as defined by estimated Glomerular Filtration Rate (eGFR) < 60.
- History of Transient Ischemic Attack (TIA) or stroke < 6 months
Lesion Specific Exclusion Criteria These exclusion criteria apply to the target lesion to be imaged by NIRS IVUS.
- Lesion located in the left main coronary artery
- Lesions that are heavily calcified
- Lesions where OCT cannot be performed due to technical difficulties
- Other lesions that the investigator deems inappropriate for the procedure such as lesions with excessive tortuosity, presence of thrombus, low flow by TIMI grade.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: DIAGNOSTIC
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: Coronary stenting with OCT, NIRS/IVUS
All subjects will have Near Infrared Spectroscopy/Intravascular Ultrasound Imaging performed.
|
Near Infrared Spectroscopy/Intravascular Ultrasound will be performed following OCT imaging.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Detection of Lipid Rich Plaque by Near Infrared Spectroscopy (NIRS) Intravascular Ultrasound (IVUS)
Time Frame: Measured one point in time during cardiac catheterization
|
Subjects are presenting for their clinically-indicated cardiac catheterization.
NIRS/IVUS imaging will be done at the time of catheterization.
|
Measured one point in time during cardiac catheterization
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Differences in NIRS Parameters Between Deep and Superficial Lipid Assessed by Optical Coherence Tomography (OCT).
Time Frame: Measured at the time of cardiac catheterization
|
Subjects are presenting for their clinically-indicated cardiac catheterization.
NIRS/IVUS imaging will be done at the time of catheterization.
Plaques were divided depending on depth of lipid by OCT (cut off value 130 um).
|
Measured at the time of cardiac catheterization
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2010P001608
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.