Cryoballoon Ablation of Pulmonary Veins After Failed RF Ablation in Patients With Paroxysmal AF
Cryoballoon Ablation of Pulmonary Veins After Failed Radiofrequency Ablation in Patients With Paroxysmal Atrial Fibrillation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 3
Contacts and Locations
Study Locations
-
-
-
Novosibirsk, Russian Federation, 630055
- State Research Institute of Circulation Pathology
-
-
-
-
New York
-
New York, New York, United States
- The Valley Health System and Columbia University College of Physicians & Surgeons
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Previous failed first radiofrequency ablation procedure (only circumferential PV isolation without linear lesions) in patients referred for second catheter ablation of AF
- > 3 months after first PVI
Exclusion Criteria:
- Congestive heart failure
- Ejection fraction <35%
- Left atrial diameter >60 mm
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Cryoballoon group
|
In Cryo group, 28mm balloon was introduced into the PV ostium with the best possible occlusion of the PV.
Every step was controlled by fluoroscopy.
Cryoenergy was applied for maximal 6 minutes per application for 2 times, resulting in a circumferential ablation lesion.
Before the right superior vein was treated, a quadripolar catheter was placed in the superior vena cava to continuously stimulate the right phrenic nerve during cryoapplication.
The application was stopped immediately in the case of diminished diaphragm movements.
|
|
Active Comparator: RF group
|
n RF group, reisolation of the PV was performed by identifying the breakthrough site.
Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation rate of 17 mL/min.
Each lesion was ablated continuously until the local potential amplitude decreased by >80% or RF energy deliveries exceeded 40 s.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Recurrence of atrial tachyarrhythmia, including AF and left atrial flutter/tachycardia, after a second ablation procedure
Time Frame: 1 year
|
1 year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Percentage of complication after procedure between two groups
Time Frame: 1 year
|
1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- RFA-655-CA
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.