Zero Heat Flux Thermometry System Comparison Trial
3M(TM)SpotOn(TM) Temperature Monitoring System Thermometry Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Pennsylvania
-
Pittsburgh, Pennsylvania, United States, 15241
- Children's Hospital of Pittsburg of the University of Pittsburgh Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Less than or equal to 17 years old
- patients undergoing surgery during which core temperature is estimated
- Willing to participate in trial
- Able to provide consent
- Adequate forehead surface area available for probe attachment
- Urology, orthopedic, or general abdominal surgery
Exclusion Criteria:
- Skin lesions at thermometer target site
- Infectious disease
- Bleeding disorder
- Prone intraoperative positioning anticipated
- Head and neck procedures
- Cardiothoracic procedures
- Tonsillectomy, cosmetic, or other brief surgical or nonsurgical procedures
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Zero-Heat-Flux
This is a single arm study.
All patients will have deep tissue temperature monitored from the nasopharyngeal and lateral forehead sites simultaneously.
|
The zero-heat-flux thermometer will be placed on the subject's lateral forehead for the duration of the surgery to measure deep tissue temperature.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Body Temperature Difference in Degrees Celsius
Time Frame: Every 5 to 10 minutes, or as clinically indicated, for the duration of the surgery from the time of incision to the time of closure. The average duration of surgery was 57 minutes.
|
Body temperature difference as defined by Agreement (bias - Zero heat flux thermometry minus nasopharyngeal) between simultaneously-acquired nasopharyngeal and forehead deep tissue temperatures as assessed by Bland and Altman repeated measures technique.
|
Every 5 to 10 minutes, or as clinically indicated, for the duration of the surgery from the time of incision to the time of closure. The average duration of surgery was 57 minutes.
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Peter J Davis, MD, University of Pittsburgh
Publications and helpful links
General Publications
- Langham GE, Maheshwari A, Contrera K, You J, Mascha E, Sessler DI. Noninvasive temperature monitoring in postanesthesia care units. Anesthesiology. 2009 Jul;111(1):90-6. doi: 10.1097/ALN.0b013e3181a864ca.
- Teunissen LP, Klewer J, de Haan A, de Koning JJ, Daanen HA. Non-invasive continuous core temperature measurement by zero heat flux. Physiol Meas. 2011 May;32(5):559-70. doi: 10.1088/0967-3334/32/5/005. Epub 2011 Mar 28.
- Fox RH, Solman AJ. A new technique for monitoring the deep body temperature in man from the intact skin surface. J Physiol. 1971 Jan;212(2):8P-10P. No abstract available.
- Togwa T, Nemoto T, Yamazaki T, Kobayashi T. A modified internal temperature measurement device. Med Biol Eng. 1976 May;14(3):361-4. doi: 10.1007/BF02478138. No abstract available.
- Matsukawa T, Sessler DI, Ozaki M, Hanagata K, Iwashita H, Kumazawa T. Comparison of distal oesophageal temperature with "deep" and tracheal temperatures. Can J Anaesth. 1997 Apr;44(4):433-8. doi: 10.1007/BF03014466.
- Harioka T, Matsukawa T, Ozaki M, Nomura K, Sone T, Kakuyama M, Toda H. "Deep-forehead" temperature correlates well with blood temperature. Can J Anaesth. 2000 Oct;47(10):980-3. doi: 10.1007/BF03024869.
- Yamakage M, Namiki A. Deep temperature monitoring using a zero-heat-flow method. J Anesth. 2003;17(2):108-15. doi: 10.1007/s005400300026. No abstract available.
- Jost U, Hanf K, Kohler CO, Just OH. [A new method for the transcutaneous measurement of deep body temperature during anaesthesia and intensive care (author's transl)]. Prakt Anaesth. 1978 Apr;13(2):144-9. German.
- Esamai F, Mining S, Forsberg P, Lewis DH. A comparison of brain, core and skin temperature in children with complicated and uncomplicated malaria. J Trop Pediatr. 2001 Jun;47(3):170-5. doi: 10.1093/tropej/47.3.170.
- Akata T, Setoguchi H, Shirozu K, Yoshino J. Reliability of temperatures measured at standard monitoring sites as an index of brain temperature during deep hypothermic cardiopulmonary bypass conducted for thoracic aortic reconstruction. J Thorac Cardiovasc Surg. 2007 Jun;133(6):1559-65. doi: 10.1016/j.jtcvs.2006.11.031.
- Yamakage M, Iwasaki S, Namiki A. Evaluation of a newly developed monitor of deep body temperature. J Anesth. 2002;16(4):354-7. doi: 10.1007/s005400200056. No abstract available.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 2012-DTT-BS-01
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.