A Prospective Randomized Trial of Prostate Biopsy Protocols Comparing the Vienna Nomogram and a Standard 10-core Biopsy Scheme
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Trans rectal ultrasound (TRUS) guided prostate biopsy remains the standard for prostate cancer diagnosis. However, the standard protocols miss 15 to 30% of cancers, leading to a variable number of repeat biopsies.
In 2005 the Vienna nomogram was introduced, defining the number of cores to be obtained in a prostate biopsy in relation to age and prostate volume in patients with a serum PSA level of 2-10 ng/mL.
The objective of the study is to determine if the Vienna nomogram increases the detection rate of trans rectal ultrasound guided prostate biopsies, compared to a 10-core biopsy.
This prospective randomized study enrolled men eligible for a prostate biopsy were randomized to a Vienna nomogram protocol or a 10-core protocol. They were further stratified according to age (≤65; >65 and ≤70; >70 years) and prostate volume (≤30; >30 and ≤50; >50 and ≤70; >70 cc).
A subgroup analysis for patients with serum PSA values between 2 and 10 ng/mL was performed.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Lisbon
-
Lisboa, Lisbon, Portugal, 1649-035
- Urology Department - Hospital de Santa Maria
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- ADULT
- OLDER_ADULT
- CHILD
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- PSA elevation
- Abnormal digital rectal examination
- Abnormal findings on prostate imaging
Exclusion Criteria:
- Active urinary tract infection
- Documented previous pathological prostatitis
- History of urinary retention
- Recent lower urinary tract surgery
Study Plan
How is the study designed?
Design Details
- Primary Purpose: DIAGNOSTIC
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: 10-core prostate biopsy protocol group
Ultrasound guided prostate biopsy with extraction of 10 cores
|
Local vascular bundle anesthesia with 2% lidocaine was performed using a 22G Chiba needle.
Ultrasound guided prostate biopsy using a standard biopsy device to obtain 10 biopsy cores.
|
|
Active Comparator: Vienna nomogram prostate biopsy protocol group
Ultrasound guided prostate biopsy performed according to the Vienna nomogram
|
Local vascular bundle anesthesia with 2% lidocaine was performed using a 22G Chiba needle.
Ultrasound guided prostate biopsy using a standard biopsy device to obtain a number of cores as defined by the Vienna nomogram.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Prostate cancer detection rate
Time Frame: Up to four weeks after intervention
|
Up to four weeks after intervention
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Prostate cancer detection rate in prostate volume and age subclasses
Time Frame: Up to four weeks after intervention
|
Up to four weeks after intervention
|
|
Gleason score concordance between biopsy and prostatectomy specimens
Time Frame: Up to four weeks after prostatectomy
|
Up to four weeks after prostatectomy
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Tito P Leitão, Dr., Hospital de Santa Maria
Publications and helpful links
General Publications
- Uzzo RG, Wei JT, Waldbaum RS, Perlmutter AP, Byrne JC, Vaughan ED Jr. The influence of prostate size on cancer detection. Urology. 1995 Dec;46(6):831-6. doi: 10.1016/s0090-4295(99)80353-7.
- Djavan B, Margreiter M. Biopsy standards for detection of prostate cancer. World J Urol. 2007 Mar;25(1):11-7. doi: 10.1007/s00345-007-0151-1. Epub 2007 Mar 7.
- Lecuona A, Heyns CF. A prospective, randomized trial comparing the Vienna nomogram to an eight-core prostate biopsy protocol. BJU Int. 2011 Jul;108(2):204-8. doi: 10.1111/j.1464-410X.2010.09887.x. Epub 2010 Nov 19.
- Remzi M, Fong YK, Dobrovits M, Anagnostou T, Seitz C, Waldert M, Harik M, Marihart S, Marberger M, Djavan B. The Vienna nomogram: validation of a novel biopsy strategy defining the optimal number of cores based on patient age and total prostate volume. J Urol. 2005 Oct;174(4 Pt 1):1256-60; discussion 1260-1; author reply 1261. doi: 10.1097/01.ju.0000173924.83392.cc.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- BPTRVienna
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.