Atrial Pressure Electrophysiology Pilot Study (APES)
Atrial Pressure Electrophysiology Pilot Study: Comparison of High vs. Low Flow Catheters During Radiofrequency Catheter Ablation (RFCA) for Atrial Fibrillation (AF).
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Illinois
-
Park Ridge, Illinois, United States, 60068
- Advocate Lutheran General Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Drug resistant paroxysmal AF
- ≥ 18 years old
Exclusion Criteria:
- Left atrial thrombus on TEE
- Patients unable to provide informed consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Low Flow Catheter
The experimental group will receive the low flow catheter (ThermoCool® SF NAV Catheter) All data will be collected pre and post procedure therefore patients will act as their own control within each therapeutic group.
|
The experimental group will receive the low flow catheter (ThermoCool® SF NAV Catheter) All data will be collected pre and post procedure therefore patients will act as their own control within each therapeutic group.
|
|
Active Comparator: High Flow Catheter
The control group will receive the higher flow catheter (ThermoCool® catheter).
All data will be collected pre and post procedure therefore patients will act as their own control within each therapeutic group.
|
The control group will receive the higher flow catheter (ThermoCool® catheter).
All data will be collected pre and post procedure therefore patients will act as their own control within each therapeutic group.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Participants With Hemodynamic, Electrolyte, and Electrophysiologic Derangements
Time Frame: Observation period is up to the 24 hours post procedure
|
The objective of this pilot study is to investigate the use of a lower flow catheter (ThermoCool® SF NAV Catheter, Biosense Webster, Inc. Diamond Bar, CA, eluting 8-15ml/minute during RF lesion delivery) vs. a higher flow catheter (ThermoCool® catheter, same manufacturer, eluting 17-30 ml/minute), Outcomes are measured by number of Participants with Hemodynamic, Electrolyte, and Electrophysiologic Derangements, is reported.
This was measured as participants requiring electrolyte replacement, if the BP dropped below 100 mm in CICU or if participants sustained atrial tachyarrhythmias
|
Observation period is up to the 24 hours post procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Scott Miller, MD, Advocate Lutheran General Hospital
Publications and helpful links
General Publications
- Kiraly LN, Differding JA, Enomoto TM, Sawai RS, Muller PJ, Diggs B, Tieu BH, Englehart MS, Underwood S, Wiesberg TT, Schreiber MA. Resuscitation with normal saline (NS) vs. lactated ringers (LR) modulates hypercoagulability and leads to increased blood loss in an uncontrolled hemorrhagic shock swine model. J Trauma. 2006 Jul;61(1):57-64; discussion 64-5. doi: 10.1097/01.ta.0000220373.29743.69.
- Antoniou A, Milonas D, Kanakakis J, Rokas S, Sideris DA. Contraction-excitation feedback in human atrial fibrillation. Clin Cardiol. 1997 May;20(5):473-6. doi: 10.1002/clc.4960200514.
- Ninio DM, Saint DA. Passive pericardial constraint protects against stretch-induced vulnerability to atrial fibrillation in rabbits. Am J Physiol Heart Circ Physiol. 2006 Nov;291(5):H2547-9. doi: 10.1152/ajpheart.01248.2005. Epub 2006 Jun 23.
- Satoh T, Zipes DP. Unequal atrial stretch in dogs increases dispersion of refractoriness conducive to developing atrial fibrillation. J Cardiovasc Electrophysiol. 1996 Sep;7(9):833-42. doi: 10.1111/j.1540-8167.1996.tb00596.x.
- Gupta A, Lawrence AT, Krishnan K, Kavinsky CJ, Trohman RG. Current concepts in the mechanisms and management of drug-induced QT prolongation and torsade de pointes. Am Heart J. 2007 Jun;153(6):891-9. doi: 10.1016/j.ahj.2007.01.040.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- #5387
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.