Study of Defibrillation Testing In Patients Undergoing Initial ICD Implantation (TNT-ICD)
"Test-No Test" Implantable Cardioverter Defibrillator Pilot Study (TNT-ICD)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Implantable cardioverter-defibrillators (ICDs) are the most effective treatment for the primary and secondary prevention of sudden cardiac death (SCD). At the time of ICD implantation, ventricular fibrillation (VF) is typically induced to demonstrate effective arrhythmia termination by the implanted device. Although defibrillation threshold (DFT) testing with induction of VF at time of ICD insertion is currently considered the "standard of care," and instructions for usage of devices approved by the Food and Drug Administration (FDA) include labeling with DFT testing, the value of defibrillation testing with modern-day devices has been questioned. Defibrillation testing can be associated with serious complications and may add to the cost of the procedure.
It is hypothesized that patients who do not undergo defibrillation testing will have outcomes similar to those who do undergo defibrillation testing at the time of initial implantation. This pilot study is being performed to determine the feasibility of performing a larger, multi-center clinical trial with longer follow-up to investigate whether or not defibrillation testing will have any impact on overall mortality, implant complications, or long-term first shock efficacy during clinical follow-up.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Contact
Study Contact
- Name: Andrea M. Russo, MD
- Phone Number: 856-968-7096
- Email: russo-andrea@cooperhealth.edu
Study Contact Backup
- Name: Julie Field
- Phone Number: 856-669-8847
- Email: Field-Julie@cooperhealth.edu
Study Locations
-
-
New Jersey
-
Camden, New Jersey, United States, 08103
- Recruiting
- Cooper University Hospital
-
Contact:
- Julie Field
- Phone Number: 856-669-8847
- Email: Field-Julie@cooperhealth.edu
-
Contact:
- Andrea M. Russo, M.D.
- Phone Number: 856-968-7096
-
Principal Investigator:
- Andrea M. Russo, MD
-
Sub-Investigator:
- John Andriulli, MD
-
Sub-Investigator:
- Matthew Ortman, MD
-
Sub-Investigator:
- Claudine Pasquarello, PA-C
-
-
Washington
-
Seattle, Washington, United States, 98195
- Not yet recruiting
- University of Washington
-
Contact:
- Jeanne Poole, MD
-
Principal Investigator:
- Jeanne Poole, MD
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Age ≥ 18 years
- Initial ICD implantation (single, dual, or CRT) for a standard Class I or Class II indication according to the ACC/AHA/HRS practice guidelines
- Anticipated life expectancy >6 months
Exclusion Criteria:
- Contraindications to defibrillation testing as determined by the managing physician*
- ICD replacement implants
- Right-sided pectoral implants
- Abdominal implants
- Chronic oral amiodarone therapy (for >6 weeks and continued need for amiodarone)
Inability to give informed consent
- Contraindications to defibrillation testing include the following: hemodynamic instability, LA thrombus, atrial fibrillation without adequate anticoagulation, LV thrombus, recent CVA or TIA, severe unrevascularized coronary artery disease or unstable angina, severe aortic stenosis, inotropic dependence, patient refusal, other patient-specific medical conditions that are deemed as contraindications, as determined by the implanting physician.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
ACTIVE_COMPARATOR: Defibrillation testing
Defibrillation testing at initial ICD implantation
|
Defibrillation testing at initial ICD implantation
Other Names:
|
|
NO_INTERVENTION: No defibrillation testing
No defibrillation testing at initial ICD implantation
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Composite all-cause mortality and operative complications
Time Frame: Procedure-related complications will be defined as those occurring within 90 days post-implantation and mortality will be measured at 2 year follow-up
|
The composite endpoint of implant complications and mortality rates will be compared in the DFT vs. no DFT groups.
|
Procedure-related complications will be defined as those occurring within 90 days post-implantation and mortality will be measured at 2 year follow-up
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
1st shock efficacy for clinical occurrence of ventricular tachycardia (VT)/VF
Time Frame: 2 years
|
The efficacy of 1st shock therapy for VT/VF will be compared between the DFT and no DFT groups.
|
2 years
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Andrea M. Russo, MD, The Cooper Health System
Publications and helpful links
General Publications
- Russo AM, Sauer W, Gerstenfeld EP, Hsia HH, Lin D, Cooper JM, Dixit S, Verdino RJ, Nayak HM, Callans DJ, Patel V, Marchlinski FE. Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion? Heart Rhythm. 2005 May;2(5):456-61. doi: 10.1016/j.hrthm.2005.01.015.
- Swerdlow CD, Russo AM, Degroot PJ. The dilemma of ICD implant testing. Pacing Clin Electrophysiol. 2007 May;30(5):675-700. doi: 10.1111/j.1540-8159.2007.00730.x.
- Mainigi SK, Cooper JM, Russo AM, Nayak HM, Lin D, Dixit S, Gerstenfeld EP, Hsia HH, Callans DJ, Marchlinski FE, Verdino RJ. Elevated defibrillation thresholds in patients undergoing biventricular defibrillator implantation: incidence and predictors. Heart Rhythm. 2006 Sep;3(9):1010-6. doi: 10.1016/j.hrthm.2006.05.028. Epub 2006 Jun 15.
- Blatt JA, Poole JE, Johnson GW, Callans DJ, Raitt MH, Reddy RK, Marchlinski FE, Yee R, Guarnieri T, Talajic M, Wilber DJ, Anderson J, Chung K, Wong WS, Mark DB, Lee KL, Bardy GH; SCD-HeFT Investigators. No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial). J Am Coll Cardiol. 2008 Aug 12;52(7):551-6. doi: 10.1016/j.jacc.2008.04.051.
- Birnie D, Tung S, Simpson C, Crystal E, Exner D, Ayala Paredes FA, Krahn A, Parkash R, Khaykin Y, Philippon F, Guerra P, Kimber S, Cameron D, Healey JS. Complications associated with defibrillation threshold testing: the Canadian experience. Heart Rhythm. 2008 Mar;5(3):387-90. doi: 10.1016/j.hrthm.2007.11.018. Epub 2007 Nov 28.
- Pires LA, Johnson KM. Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough? J Cardiovasc Electrophysiol. 2006 Feb;17(2):140-5. doi: 10.1111/j.1540-8167.2005.00294.x.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CUH-09-087
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Ventricular Arrhythmias
-
NCT07590908CompletedVentricular Tachycardia | Ventricular Arrhythmias
-
NCT07201506RecruitingVentricular Tachycardia | Ventricular Arrhythmia | Premature Ventricular Contractions | Ablation of Arrhythmias
-
NCT06360003CompletedVentricular Outflow Tract Ventricular Arrhythmias | Radio Frequency Catheter Ablation
-
NCT07566208Not yet recruitingVentricular Arrhythmias and Cardiac Arrest
-
NCT07026695Not yet recruitingVentricular Arrhythmias | Ventricular Tachycardia (VT) | Premature Ventricular Complexes
-
NCT07375264CompletedVentricular Arrhythmias | Stellate Ganglion Block | Electrical Storm
-
NCT06281977RecruitingVentricular Fibrillation | Ventricular Tachycardia | Ventricular Arrhythmias | Recurrent Ventricular Tachycardia
-
NCT05084391WithdrawnCardiac Arrhythmia | Cardiac | Ventricular Tachyarrhythmias
-
NCT06747013Enrolling by invitationVentricular Tachycardias | Premature Ventricular Contractions | Focal Ventricular Arrhythmias
-
NCT04774523CompletedHeart Failure | Cardiac Arrhythmia | Left Ventricular Dysfunction
Clinical Trials on Defibrillation testing
-
NCT03495297Completed
-
NCT02513030UnknownDefibrillation Capacity of Defibrilators After Replacement
-
NCT00385749UnknownTachycardia, Ventricular | Heart Failure, Congestive
-
NCT02111993CompletedEvaluating Myocardial Injury for Defibrillation Threshold Testing Methods for ICD Implantation (ULV)Heart Failure | Cardiac Arrhythmia | Cardiomyopathy
-
NCT06447805CompletedCardiac Arrest | Sudden Cardiac Death | Sudden Cardiac Arrest | Fibrillation, Ventricular
-
NCT01665755CompletedDeath | Ventricular Fibrillation | Ventricular Tachycardia | Sudden Cardiac Death | Cardiac Event
-
NCT03249948CompletedVentricular Fibrillation
-
NCT00212992Completed
-
NCT06131892CompletedHypothermia, Accidental | Defibrillation
-
NCT07005232Enrolling by invitation