Adequate Additional Bronchial Cuff Volume to Achieve Blood-tight Seal After Air-tight Seal in Double Lumen Tube
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Jae-Hyon Bahk, MD, PhD
- Phone Number: 82-2-2072-2818
- Email: bahkjh@snu.ac.kr
Study Locations
-
-
-
Seoul, Korea, Republic of
- Recruiting
- Seoul National University Hospital
-
Contact:
- Jae-Hyon Bahk, MD, PhD
- Phone Number: 82-2-2072-2818
- Email: bahkjh@snu.ac.kr
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- patients undergoing thoracic surgery under left lower decubitus position, using left sided double lumen tube
- patient's left main bronchus size adequate for 35Fr, 37 Fr, 39 Fr double lumen tube
Exclusion Criteria:
- dislocation or great movement of double lumen tube depth
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: 39 Fr double lumen group
patients are assigned to 35 Fr, 37 Fr, 39 Fr double lumen tube group according to their left main bronchus diameter measured by preoperative chest CT, to minimize difference between main bronchus diameter and bronchial tip diameter of double lumen tube
|
additional bronchial cuff volume is decided according to up-and-down biased coin design sequential method, by incremental volume of 0.1 ml
|
|
Experimental: 37 Fr double lumen group
patients are assigned to 35 Fr, 37 Fr, 39 Fr double lumen tube group according to their left main bronchus diameter measured by preoperative chest CT, to minimize difference between main bronchus diameter and bronchial tip diameter of double lumen tube
|
additional bronchial cuff volume is decided according to up-and-down biased coin design sequential method, by incremental volume of 0.1 ml
|
|
Experimental: 35 Fr double lumen tube group
patients are assigned to 35 Fr, 37 Fr, 39 Fr double lumen tube group according to their left main bronchus diameter measured by preoperative chest CT, to minimize difference between main bronchus diameter and bronchial tip diameter of double lumen tube
|
additional bronchial cuff volume is decided according to up-and-down biased coin design sequential method, by incremental volume of 0.1 ml
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
leakage of autologus blood through bronchial cuff
Time Frame: 10, 20, 30 minutes after dripping of blood around bronchial cuff
|
10, 20, 30 minutes after dripping of blood around bronchial cuff
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- JHBahk_DLT_bloodtightseal
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Preventing Blood Leakage of Bronchial Cuff
-
NCT05670808Not yet recruitingTo Determine the Optimal Doses of Adrenaline in Preventing Blood Loos in Participants Undergoing Supraclavicular Flap Surgery
-
NCT04590898CompletedStroke | Atrial Fibrillation | Bleeding | Leakage of Cardiac Device
-
NCT04294108CompletedPain, Postoperative | Carcinoma, Non-Small-Cell Lung | Atrial Fibrillation | Postoperative Nausea and Vomiting | Infection | Air Leakage
-
NCT01250444UnknownImprovement of Functional Capacity. | Improvement of Quality of Life. | Improvement of Cardiovascular Autonomic Control. | Reduction of Blood Pressure in Hypertensive Patients.
-
NCT01784458CompletedPneumonia | Abscess | Peritonitis | Leakage | Bowel Perforation
-
NCT05688722CompletedApnea | Surgery | Desaturation of Blood
-
NCT03062137CompletedLung Diseases | Desaturation of Blood
-
NCT04832633CompletedRadiation Exposure | Enhancement of Aorta and Pulmonary Artery
-
NCT03079102TerminatedHeart Arrest, Out-Of-Hospital
-
NCT03479905TerminatedColonoscopy | Desaturation of Blood
Clinical Trials on 39 Fr double lumen tube group
-
NCT07362797Not yet recruitingThoracoscopic Surgery | Double Lumen Tube Intubation
-
NCT07467005Not yet recruitingLung Cancer | Pulmonary Nodule
-
NCT03690284CompletedSingle Lung Ventilation | Double Lumen Endotracheal Tube
-
NCT04101734CompletedPredictive Value of Tests | Intubation;Difficult
-
NCT03624439CompletedIntubation; Difficult or Failed | Difficult Airway | Intubation;Difficult
-
NCT02253979CompletedEndotracheal Intubation | Airway Management | One Lung Ventilation
-
NCT02594956CompletedPancreaticoduodenectomy | Digestive System Surgical Procedure
-
NCT03889847Completed