The Clinical Efficacy of Supraglottic Airway Device, Self-pressurized Air-Q Intubating Laryngeal Airway (ILA -SP) in Adult Patients: Comparison With Classic-laryngeal Airway (c-LMA)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Seoul, Korea, Republic of, 120-752
- Human research Protection Center, Gangnam Severance Hospital,
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Adult patients (20-75 of age) scheduled for elective surgery of short duration (less than 2 hr) undergoing general anesthesia using supraglottic airway
Exclusion Criteria:
- Patients with a potentially difficult airway, risk of aspiration such as gastroesophageal reflux disease, or active upper respiratory tract infection
Study Plan
How is the study designed?
Design Details
- Primary Purpose: OTHER
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: DOUBLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: 1)C-LMA group
|
After induction of general anesthesia, C-LMA or Air-Q was inserted according to randomly allocated group.
|
|
ACTIVE_COMPARATOR: 2)Air-Q group
|
After induction of general anesthesia, C-LMA or Air-Q was inserted according to randomly allocated group.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
airway leak pressure measured after device insertion
Time Frame: within 5min to 10 min insertion of each device
|
Airway leak pressure was determined by adjusting the expiratory valve of the breathing circle to 40 cmH2O (fixed fresh gas flow 3 L/min) and recording the pressure when equilibrium was reached.
|
within 5min to 10 min insertion of each device
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Insertion time
Time Frame: During and 1 min after insertion of each device
|
Insertion time was defined as the time from the attending anesthesiologist picking up the LMA until the confirmation on capnography.
|
During and 1 min after insertion of each device
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Ease of insertion
Time Frame: During and 1 min after insertion of each device
|
Ease of insertion was graded from 1 to 4.
|
During and 1 min after insertion of each device
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 3-2014-0081
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.