Evaluation of Respiratory Acoustic Monitor in Children After Surgery
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Ohio
-
Cincinnati, Ohio, United States, 45229
- Cincinnati Children's Hospital Medical Center
-
-
Texas
-
Dallas, Texas, United States, 75235
- UT Southwestern Medical Center - Dallas
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Male or female children 2 to 16 years of age
- In-patients or 23 hour short stay patients who had a tonsillectomy with a diagnosis or symptoms of obstructive sleep apnea or who had any surgery and receiving an opioid by patient controlled analgesia for post-operative pain control
- Child weighs at least 10 kg on day of surgery
Exclusion Criteria:
- Patient has skin abnormalities (rash, eczema, etc.) at the planned application sites that would interfere with sensor or electrode applications.
- Patient is admitted to the Intensive Care Unit
- Patient has tracheostomy
- Patient is on non-invasive ventilator support
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Respiratory Acoustic Monitoring
All participants will wear the respiratory acoustic monitoring device.
|
Examine the reliability and accuracy of the respiratory acoustic monitor.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Reliability/ Accuracy of Respiratory Acoustic Monitoring (RAM)
Time Frame: Up to 24 hours after surgery
|
The respiratory acoustic monitor records three vital signs: Respiration rate recorded in breaths per minute, oxygen saturation recorded in percentage, and heart rate recorded in beats per minute. The reliability and accuracy of the respiratory data collected by the RAM was examined by comparing to data collected clinically by the manual counting of the respiratory rate and by the respiratory rate measure by transthoracic impedance . The accuracy of RAM was examined when a staff member goes and register these measurements that occur simultaneously during the first minute of every 2 hour interval to a maximum of a 24 hour monitoring time. |
Up to 24 hours after surgery
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Presence of False Alarms
Time Frame: Up to 24 hours after surgery
|
To evaluate the presence of false alarms, bedside clinical monitoring was done every two hour during 5 to 15 minutes (random sample) recording the respiratory rates and evaluating the presence of alarms.
If an alarm was activated during the bedside monitoring, it was verified by the investigator if the respiratory rate provided by the device was consistent with the clinical evaluation.
False alarms were considered those alarms that are triggered by the device, but during simultaneous clinical evaluation it was verified that the number of breaths per minute were inaccurate.
Therefore, the higher number of false alarms detected by one type of monitoring indicates that the device is less reliable detecting the respiratory rate.
|
Up to 24 hours after surgery
|
|
Tolerance of the RAM
Time Frame: Up to 24 hours after surgery
|
The tolerance is defined as the ratio of the time the sensor stays in place divided by the total expected time of monitoring, expressed as a percentage.
The tolerance to the transthoracic impedance pads was not evaluated during this study considering that this is the standard monitoring and that is usually tolerated during the total expected time of monitoring.
|
Up to 24 hours after surgery
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Mario Patino, MD, Children's Hospital Medical Center, Cincinnati
- Principal Investigator: Peter Szmuk, MD, UT Southwestern Medical Center- Dallas
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 2014-6421
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Pediatric
-
NCT07527546Not yet recruitingPediatric Anesthesia | Pediatric Postoperative Recovery | Pediatric Enhanced Recovery After Surgery
-
NCT02904278CompletedPediatric Heart Transplantation | Pediatric Heart Transplant Recipients | Pediatric Cardiac Transplantation
-
NCT07371026Not yet recruitingPediatric | Pediatric Acute Upper Respiratory Tract Infection | Pediatric Acute Respiratory Failure
-
NCT07493018Not yet recruitingPediatric Oncology | Pediatric Hematology
-
NCT02638428RecruitingRelapsed Pediatric AML | Refractory Pediatric AML | Relapsed Pediatric Solid Tumor | Refractory Pediatric Solid Tumor
-
NCT03939728TerminatedPediatric Lung Ultrasound | Pediatric Chest Radiography | Pediatric Lung Diagnosis
-
NCT03455140CompletedCancer | Pediatric ALL | Pediatric Solid Tumor | Pediatric AML
-
NCT07617662Not yet recruitingPediatric Dental Anxiety | Pediatric Dental Pain
-
NCT07289152RecruitingPediatric Anesthesia | PROMs | Pediatric Surgery | PREMs
Clinical Trials on Respiratory Acoustic Monitor
-
NCT01494844CompletedRespiratory Device Comfort
-
NCT07552025Not yet recruitingApnea of Prematurity | Periodic Breathing | Preterm Infant | Hypopnea
-
NCT04356443TerminatedCOVID-19 | Pneumonia | Respiratory Failure | ARDS, Human | Ventilatory Failure
-
NCT07516470RecruitingAnesthesia, General | Hemodynamic Monitoring | Fluid Responsiveness Predictability
-
NCT04003415CompletedAsthma | Copd | Respiratory Effort | Contactless Vital Sign Monitoring
-
NCT07650539Not yet recruitingRespiratory Monitoring
-
NCT04821011Completed
-
NCT06911541CompletedRespiratory Rate | Capnography | Wireless Vital Signs Monitoring System | Respiratory Rate Accuracy Test
-
NCT02899351CompletedRespiratory Complications