Hemodynamic Survey Cardiac Surgical Scenarios
Comparative Hemodynamic Assessment Between Lidco Rapid and Pulmonary Artery Thermodilution
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Data from PA catheter such as PA pressure, pulmonary wedge pressure and cardiac output has been widely used in the various clinical situations warranting advance hemodynamic monitoring. It is considered as gold standard but unfortunately there is always risk associated with PA catheter and time lag between the clinical events and interpretation. Lidco Rapid is one of the non-invasive hemodynamic tools to measure various parameters. It is widely used in the intensive care set up for goal directed therapy but unfortunately there is not enough data to show whether it is useful in various peri-operative clinical conditions. In the online based survey, responses from the participants are recorded in the nominal scale ( 1 to 5 where 3 represents near normal). This survey will help to determine whether Investigators can replace the Lidco in any clinical situation warranting advance hemodynamic monitoring.
No previous study was done to specifically find out the hemodynamic component that differs between these tools intraoperatively in varying hemodynamic conditions during cardiac surgery although there were few studies compared the trend in the cardiac output with difference in opinion on their accuracy.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Must be a certified Anesthesiologist with cardiac fellowship training
Exclusion Criteria:
- none
Study Plan
How is the study designed?
Design Details
- Time Perspectives: Prospective
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
To expect difference is within 1 unit ( scale of 1 to 5) in the hemodynamic assessment preferably preload , afterload and contractility between Lidco and data from PA catheter in different cardiac surgical patient scenarios.
Time Frame: intraoperative
|
intraoperative
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Sudhakar Subramani, M.D., University of Iowa
Publications and helpful links
General Publications
- Hadian M, Kim HK, Severyn DA, Pinsky MR. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care. 2010;14(6):R212. doi: 10.1186/cc9335. Epub 2010 Nov 23.
- Broch O, Renner J, Hocker J, Gruenewald M, Meybohm P, Schottler J, Steinfath M, Bein B. Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery. Crit Care. 2011;15(1):R76. doi: 10.1186/cc10065. Epub 2011 Feb 28.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 201504777
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Low Cardiac Output
-
NCT02422342UnknownLow Cardiac Output | High Cardiac Output
-
NCT05999487Not yet recruitingDobutamine, Milrinone , Pediatrics , Low Cardiac Output
-
NCT02771080CompletedLow Cardiac Output Syndrome After Adult Cardiac Surgery
-
NCT06759506Not yet recruitingPerfusion Index and Cerebral NIRS Trends in Low Cardiac Output Syndrome
-
NCT02511457Completed
-
NCT02599376Completed
-
NCT00529711Completed
-
NCT00167440Withdrawn
-
NCT00529490Completed
-
NCT00994825CompletedLow Cardiac Output Syndrome
Clinical Trials on LIDCO Rapid, Pulmonary artery catheter
-
NCT05485376RecruitingHeart Failure | Cardiogenic Shock
-
NCT02964026CompletedCardiac Surgery | Thoracic Surgery | Heart Surgery | Heart Transplant
-
NCT00464750Completed
-
NCT05524558RecruitingARDS, Human | Ventilation Therapy; Complications | Alveolar; Disorder
-
NCT04515511UnknownSeptic Shock | Fluid Therapy | Hemodynamic Instability
-
NCT00281268CompletedLung Diseases | Acute Respiratory Distress Syndrome
-
NCT00234767CompletedLung Diseases | Acute Respiratory Distress Syndrome | Acute Lung Injury
-
NCT06198621Not yet recruitingCardiac Output, Low