First-in-man Sirolimus-eluting Prolim® Stent Registry
Novel Sirolimus-eluting Stent Prolim® With a Biodegradable Polymer in the All-comers Population
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- age ≥ 18 years old,
- stable coronary artery disease (SCAD) or acute coronary syndrome (unstable angina - UA, non-ST elevation myocardial infarction - NSTEMI or ST-elevation myocardial infarction - STEMI) and
- signed informed consent
Exclusion Criteria:
- inability to take dual antiplatelet therapy for 12 months,
- left ventricular ejection fraction ≤ 30%,
- chronic total occlusions, and
- in-stent restenosis
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Prolim stent implantation
In patients with symptomatic coronary artery disease Prolim stent was implanted in coronary arteries
|
Prolim stent was implanted in patients who signed the informed consent and met the exclusion and inclusion criteria.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The primary endpoint was the cumulative rate of major adverse cardiovascular events (MACE).
Time Frame: 12 months
|
consisting of cardiac death, myocardial infarction (MI) and clinically-driven target lesion revascularization (TLR)
|
12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Secondary endpoints included the rates of cardiac death, all-cause death, MI, TLR, TVR and stent thrombosis.
Time Frame: 12 moths
|
Secondary endpoints included the rates of cardiac death, all-cause death, MI, TLR, TVR and stent thrombosis.
|
12 moths
|
|
Late lumen loss (LLL)
Time Frame: 12 moths
|
The value (in mm) of LLL assessed in qualitative coronary angiography (QCA)
|
12 moths
|
|
The percentage of covered struts assessed in optical coherence tomography (OCT)
Time Frame: 12 months
|
The percentage of covered struts assessed in OCT
|
12 months
|
|
The neointima volume assessed in OCT
Time Frame: 12 months
|
The neointima volume (in mm3) assessed in OCT
|
12 months
|
|
The device success rate
Time Frame: intraoperative
|
The percentage of Prolim stents successfully implanted.
|
intraoperative
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Jacek Bil, MD, PhD, Central Clinical Hospital of the Ministry of Internal Affairs
Publications and helpful links
General Publications
- Stettler C, Wandel S, Allemann S, Kastrati A, Morice MC, Schomig A, Pfisterer ME, Stone GW, Leon MB, de Lezo JS, Goy JJ, Park SJ, Sabate M, Suttorp MJ, Kelbaek H, Spaulding C, Menichelli M, Vermeersch P, Dirksen MT, Cervinka P, Petronio AS, Nordmann AJ, Diem P, Meier B, Zwahlen M, Reichenbach S, Trelle S, Windecker S, Juni P. Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis. Lancet. 2007 Sep 15;370(9591):937-48. doi: 10.1016/S0140-6736(07)61444-5.
- Lavi S, Dzavik V. Biodegradable Stent Platforms: Are We Heading in the Right Direction? Can J Cardiol. 2015 Aug;31(8):957-9. doi: 10.1016/j.cjca.2015.04.005. Epub 2015 Apr 14. No abstract available.
- Nagoshi R, Shinke T, Otake H, Shite J, Matsumoto D, Kawamori H, Nakagawa M, Kozuki A, Hariki H, Inoue T, Ohsue T, Taniguchi Y, Iwasaki M, Nishio R, Hiranuma N, Konishi A, Kinutani H, Miyoshi N, Takaya T, Yamada S, Yasaka Y, Hayashi T, Yokoyama M, Kato H, Kadotani M, Ohnishi Y, Hirata K. Qualitative and quantitative assessment of stent restenosis by optical coherence tomography: comparison between drug-eluting and bare-metal stents. Circ J. 2013;77(3):652-60. doi: 10.1253/circj.cj-12-0610. Epub 2012 Dec 21.
- Zhang Q, Qiu JP, Kirtane AJ, Zhu TQ, Zhang RY, Yang ZK, Hu J, Ding FH, DU R, Shen WF. Comparison of biodegradable polymer versus durable polymer sirolimus-eluting stenting in patients with acute st-elevation myocardial infarction undergoing primary percutaneous coronary intervention: results of the RESOLVE study. J Interv Cardiol. 2014 Apr;27(2):131-41. doi: 10.1111/joic.12102.
- Bil J, Gil RJ, Kern A, Pawlowski T, Seweryniak P, Sliwinski Z. Novel sirolimus-eluting stent Prolim(R) with a biodegradable polymer in the all-comers population: one year clinical results with quantitative coronary angiography and optical coherence tomography analysis. BMC Cardiovasc Disord. 2015 Nov 14;15:150. doi: 10.1186/s12872-015-0139-5.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 1.0
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.