Comparison of Ventilation Distribution Between Tidal Volume 6ml/kgBW and 10ml/kgBW
Comparison of Ventilation Distribution Between Tidal Volume 6ml/kgBW and 10ml/kgBW in Laparoscopic Nephrectomy Patients
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
DKI Jakarta
-
Jakarta, DKI Jakarta, Indonesia, 10430
- Cipto Mangunkusumo Central National Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Subjects aged 18-60 years old
- Subjects with good health condition (did not suffer from cancer, diabetes mellitus, kidney diseases, cardiovascular diseases, liver diseases, hematologic disorders, HIV, hepatitis)
- Subjects had the same blood type with the renal recipients and had passed cross match test
- Subjects were willing to be renal donors.
Exclusion Criteria:
- Subjects with pulmonary diseases or PaO2 (arterial partial pressure of oxygen) /FiO2 < 300 mmHg
- Subjects with Body Mass Index (BMI) > 30 kg/m2
- Subjects who had mechanical ventilation 2 weeks prior to the surgery
- Subjects with congestive heart failure
- Subjects with neuromuscular diseases.
Drop out criteria:
- Subjects with intraoperative pulmonary complications not due to ventilation
- Subjects with intraoperative cardiac arrest
- Subjects with desaturation that could not be managed by FiO2 increase, PEEP or recruitment maneuver, and required tidal volume changes.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Tidal volume 6 ml/kgBW
Tidal volume 6 ml/kgBW was given to patients after endotracheal tube was inserted properly
|
Tidal volume 6ml/kgBW was given to subjects after endotracheal tube was inserted properly.
|
|
Active Comparator: Tidal volume 10 ml/kgBW
Tidal volume 10 ml/kgBW was given to patients after endotracheal tube was inserted properly.
|
Tidal volume 10 ml/kgBW was given to subjects after endotracheal tube was inserted properly.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Tidal impedance variation regional (TIV-ROI)
Time Frame: 2 months
|
Evaluating ROI values displayed on EIT Dräger PulmoVista® 500 monitor.
|
2 months
|
|
Global End expiratory lung impedance difference (ΔEELI-g)
Time Frame: 2 months
|
Global End expiratory lung impedance difference (ΔEELI-g) will be measured by the EIT monitor.
|
2 months
|
|
Regional End expiratory lung impedance difference (ΔEELI- ROI)
Time Frame: 2 months
|
Regional End expiratory lung impedance difference (ΔEELI-g) will be measured by the EIT monitor.
|
2 months
|
|
Compliance regional (CR)
Time Frame: 2 months
|
Tidal Impedance Variation value divided by atmospheric pressure above PEEP value.
|
2 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Dita Aditianingsih, Consultant, Indonesia University
Publications and helpful links
General Publications
- Acute Respiratory Distress Syndrome Network, Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000 May 4;342(18):1301-8. doi: 10.1056/NEJM200005043421801.
- Jha V, Garcia-Garcia G, Iseki K, Li Z, Naicker S, Plattner B, Saran R, Wang AY, Yang CW. Chronic kidney disease: global dimension and perspectives. Lancet. 2013 Jul 20;382(9888):260-72. doi: 10.1016/S0140-6736(13)60687-X. Epub 2013 May 31. Erratum In: Lancet. 2013 Jul 20;382(9888):208.
- Rizzotti L, Vassiliou M, Amygdalou A, Psarakis Ch, Rasmussen TR, Laopodis V, Behrakis P. Respiratory system mechanics during laparoscopic cholecystectomy. Respir Med. 2002 Apr;96(4):268-74. doi: 10.1053/rmed.2001.1264.
- Futier E, Constantin JM, Paugam-Burtz C, Pascal J, Eurin M, Neuschwander A, Marret E, Beaussier M, Gutton C, Lefrant JY, Allaouchiche B, Verzilli D, Leone M, De Jong A, Bazin JE, Pereira B, Jaber S; IMPROVE Study Group. A trial of intraoperative low-tidal-volume ventilation in abdominal surgery. N Engl J Med. 2013 Aug 1;369(5):428-37. doi: 10.1056/NEJMoa1301082.
- Ricard JD, Dreyfuss D, Saumon G. Ventilator-induced lung injury. Eur Respir J Suppl. 2003 Aug;42:2s-9s. doi: 10.1183/09031936.03.00420103.
- de Prost N, Ricard JD, Saumon G, Dreyfuss D. Ventilator-induced lung injury: historical perspectives and clinical implications. Ann Intensive Care. 2011 Jul 23;1(1):28. doi: 10.1186/2110-5820-1-28.
- Costa EL, Lima RG, Amato MB. Electrical impedance tomography. Curr Opin Crit Care. 2009 Feb;15(1):18-24. doi: 10.1097/mcc.0b013e3283220e8c.
- Moerer O, Hahn G, Quintel M. Lung impedance measurements to monitor alveolar ventilation. Curr Opin Crit Care. 2011 Jun;17(3):260-7. doi: 10.1097/MCC.0b013e3283463c9c.
- Victorino JA, Borges JB, Okamoto VN, Matos GF, Tucci MR, Caramez MP, Tanaka H, Sipmann FS, Santos DC, Barbas CS, Carvalho CR, Amato MB. Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. Am J Respir Crit Care Med. 2004 Apr 1;169(7):791-800. doi: 10.1164/rccm.200301-133OC. Epub 2003 Dec 23.
- Riera J, Riu PJ, Casan P, Masclans JR. [Electrical impedance tomography in acute lung injury]. Med Intensiva. 2011 Nov;35(8):509-17. doi: 10.1016/j.medin.2011.05.005. Epub 2011 Jun 15. Spanish.
- Lorenzo AJ, Karsli C, Halachmi S, Dolci M, Luginbuehl I, Bissonnette B, Farhat WA. Hemodynamic and respiratory effects of pediatric urological retroperitoneal laparoscopic surgery: a prospective study. J Urol. 2006 Apr;175(4):1461-5. doi: 10.1016/S0022-5347(05)00668-3.
- Goncalves LO, Cicarelli DD. Alveolar recruitment maneuver in anesthetic practice: how, when and why it may be useful. Rev Bras Anestesiol. 2005 Dec;55(6):631-8. doi: 10.1590/s0034-70942005000600006. English, Portuguese.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- IndonesiaUAnes004
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.