Variable Approaches of Intradiscal O3-O2 Injection
Variable Approaches of Intradiscal O3-O2 Injection for Management of Low Back Pain: Could it Make a Difference? a Prospective Double Blind Randomized Clinical Trial.
Cost Intradiscal injection of ozone-oxygen mixture (O3-O2) which offers a rapid onset amelioration of symptoms, with a sustained duration pain relief in low back pain.
Does change of injection approach make a difference?
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Low back pain (LBP) mostly is induced by disc herniation (DH), or degeneration and has a burden upon social and economic aspects of life. Medical and or surgical interventions have been used to resolve this problem, but one of the newly introduced is the minimally invasive low cost Intradiscal injection of ozone-oxygen mixture (O3-O2) which offers a rapid onset amelioration of symptoms, with a sustained duration pain relief.
A lot of injection approaches are available, but which offers the best results, is the question.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Assiut, Egypt, 71111
- Emad Zarief Kamel Said
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- radicular leg pain
- low back pain
- non-responsive to conservative treatment
Exclusion Criteria:
- patient refusal
- infection at injection site
- coagulopathy
- uncontrolled or degenerative spine disease
- pregnancy
- multilevel disk involvement
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: A: Classic approach
Intradiscal O3 injection through classic postrolateral extraarticular percutaneous approach. The participants will receive 10 ml of ozone oxygen mixture 30 ug O3/ml O2. The ozone-oxygen mixture was produced in real-time by a medical ozone generator (Ozonline E 80, Medica srl, Bologna Italy). |
Receive 10 ml of ozone oxygen mixture 30 ug O3/ml O2 through the classic postrolateral extraarticular percutaneous approach
|
|
Active Comparator: B: Transforaminal approach (Yess approach )
Participants will receive 10 ml of ozone oxygen mixture 30 ug O3/ml O2 through postrolateral transforaminal approach (Yess approach). The ozone-oxygen mixture was produced in real-time by a medical ozone generator (Ozonline E 80, Medica srl, Bologna Italy). |
Group B receive 10 ml of ozone oxygen mixture 30 ug O3/ml O2 through postrolateral transforaminal approach (Yess approach ).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Quality of pain alleviation (visual analog scale)
Time Frame: one year
|
assessing visual analog scale (VAS)
|
one year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Analgesia reduction (percent)
Time Frame: one year
|
the percent of analgesia reduction
|
one year
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Abdelraheem Alawaamy, MD, Assiut University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IRB00009903
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Low Back Pain
-
NCT07582705CompletedLower Back Pain | Low Back Pain | Low Back Pain, Mechanical | Low Back Pain, Recurrent | Low Back Pain, Postural | Postural Low Back Pain | Mechanical Low Back Pain | Low Back Ache | Recurrent Low Back Pain | Lower Back Pain Chronic
-
NCT05616702RecruitingLow Back Pain | Chronic Low-back Pain | Low Back Pain, Mechanical | Mechanical Low Back Pain | Pain, Chronic | Pain, Back | Lower Back Pain Chronic | CLBP - Chronic Low Back Pain
-
NCT04216810CompletedLow Back Pain, Mechanical | Low Back Pain, Postural | Lower Back Pain Chronic | Low Back Pain, Posterior Compartment
-
NCT06552962CompletedLow Back Pain | Low Back Pain, Mechanical | Low Back Pain, Recurrent | Low Back Pain, Postural
-
NCT04554563CompletedLow Back Pain | Low Back Pain, Mechanical | Low Back Pain, Postural
-
NCT07030816CompletedChronic Low Back Pain | Non-specific Low Back Pain | Low Back Pain (LBP)
-
NCT03597191CompletedLow Back Pain | Chronic Low Back Pain | Subacute Low Back Pain
-
NCT02037763UnknownChronic Low Back Pain | Acute Low Back Pain
-
NCT06841107CompletedLow Back Disorder | Low Back Pain (LBP)
-
NCT04494698CompletedChronic Low-back Pain | Pain, Intractable | Acute Low-back Pain