Laryngeal Pacing Study (BVFP IDE)
Electrical Stimulation of Laryngeal Muscles to Restore Glottal Opening in Patients with Bilateral Vocal Fold Paralysis
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The recurrent laryngeal nerve (RLN) carries motor fibers that innervate both the abductor (PCA, opener) muscle and adductor (closer) muscles of the vocal folds. Damage to the nerve compromises both of these functions and arrests the vocal folds in a near-closed position. In case of BVFP, voice tends to be functional but airway embarrassment is often severe enough to warrant tracheostomy to relieve inspiratory stridor and dyspnea.
If spontaneous recovery from nerve injury does not occur within one year, it is likely the patient will be chronically paralyzed. In such instances, long-term tracheostomy could be considered. Unfortunately, permanent tracheostomy is known to have the complications of tracheal stenosis, chronic infection, and psycho-social impairment. For this reason, laryngeal surgery is offered to enlarge the airway and restore breathing through the mouth. These procedures, such as arytenoidectomy and cordotomy, where a portion of the larynx is surgically resected to enlarge the airway, also have inherent complications.
Although they represent the standard of care, they adversely affect voice and may compromise airway protection during swallowing. Further, they cannot provide sufficient airway to permit significant aerobic activity. The limitations associated with these current therapies have prompted investigation into a more physiologic, dynamic approach to rehabilitation: reanimation of the paralyzed PCA muscle by functional electrical stimulation (FES). Stimulation would be applied to the PCA muscle during the inspiratory phase of respiration to open the vocal folds. During noninspiratory phases, stimulation would cease and the vocal folds would passively relax to the midline to allow for normal voice production and airway protection in swallowing. Based on the research the investigators have conducted, the investigators expect patients would benefit from bilateral pacing through implantation of the neurostimulator by restoring normal ventilation, without negatively affecting the patient's voice or swallowing ability.
The investigators are collecting data in this study to show that this procedure is an effective means of a surgical approach for implantation of device with insertion and anchoring of the electrode leads. Incidence of complications both intraoperatively and postoperatively will also be collected and assessed. Any complications will be addressed according to current standard practice under the supervision of the operating surgeon. The device should produce an airway that will allow patients to breathe without a tracheostomy tube in place. Patients will be monitored for adverse events and managed accordingly.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Male or female adult patients, 22 years of age or older
- Diagnosis of bilateral vocal fold paralysis, at least one year prior to study enrollment
- Must have tracheostomy in place minimum of 6 weeks prior to implantation of St.Jude Medical Infinity™ IPG device
- Demonstrated glottal opening bilaterally (abductory response) upon percutaneous needle stimulation of PCA muscles
- Demonstrated peak inspiratory flow with respiratory testing through the mouth of at least 0.4 L/sec
Exclusion Criteria:
- Any active illness that is associated with an immune disorder (such as diabetes)
- History of cardiac dysrhythmias or implanted cardiac pacemaker
- Any electronic implanted medical device that, in the investigator's opinion, could interact with the laryngeal pacemaker
- Active cardiac disease manifested by unstable angina, recent myocardial infarction, malignant arrhythmias, uncontrolled hypertension (diastolic greater than 110), or decompensated congestive heart failure
- Patients with underlying comorbidities that, in the investigator's opinion, could potentially warrant a need for oxygen therapy, including but not limited to: Chronic obstructive pulmonary disease, asthma, emphysema, recurrent bronchitis, pneumonia or interstitial lung disease
- Bilateral laryngeal immobility from stenosis or arthritis
- Poor Surgical risk patients as determined by the treating surgeon or Vanderbilt Preoperative Evaluation Center (VPEC)
- Patients with acute or chronic infections
- The abundance of interstitial fat may impede the surgical dissection. In the opinion of the principal investigator or treating physician(s), patients with factors that may complicate the surgical intervention will be excluded.
- Known allergy to barium dye or anesthetics
- Known allergy to any of the device materials
- Patients who in the opinion of the investigator, based on needle stimulation testing, have insufficient PCA muscle mass to implant leads
- Patients with pre-existing liquid dysphagia
- Presence of significant tracheal narrowing
- Any anatomical abnormality that would jeopardize safe implantation, per the treating surgeon
- Any medical condition, that in the opinion of the principal investigator or treating physician, would jeopardize the outcome or welfare of the participant
- Any history of keloid formation or hypertrophic scarring
- Females who are pregnant or plan a pregnancy within 1 year. A pregnancy test will be done as part of the routine pre-operative assessment for all females of childbearing potential.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Investigational Device
Patient who meets eligibility to be implanted with the St. Jude Medical Infinity™ Implantable Pulse Generator System (P140049), St. Jude Medical Infinity™ Deep Brain Stimulation (DBS) Directional Lead and Extension (P140009), Swift-Lock™ Anchor (K092371), Butterfly anchor (P140009), manufactured by St. Jude Medical, Inc.
|
Device is an implantable neurostimulation system designed to deliver low-intensity electrical impulses to nerve structures.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Demonstration of a consistent surgical approach with successful implantation and functionality of a laryngeal pacemaker, as indicated by the presence of stimulated motion of the chronically paralyzed vocal fold.
Time Frame: 12 to 15 months
|
12 to 15 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Increased glottal area due to laryngeal pacemaker stimulation as assessed by increase in standard assessment testing.
Time Frame: 12 to 15 months
|
12 to 15 months
|
|
Increased ventilation due to laryngeal pacemaker stimulation as assessed by increase in standard assessment testing.
Time Frame: 12 to 15 months
|
12 to 15 months
|
|
Minimal impairment of voice due to laryngeal pacemaker stimulation as assessed by increase in standard assessment testing.
Time Frame: 12 to 15 months
|
12 to 15 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: David L. Zealear, PhD, Vanderbilt University Medical Center
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 141242
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.