Image-guided Cochlear Implant Programming (IGCIP)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Over 320,000 individuals have received cochlear implants (CIs) to restore hearing to the hearing impaired. Commercially available CIs have 12, 16, or 22 independent electrodes (the number is dependent on the manufacturer of the CI) which cover the entire frequency spectrum of the cochlea from 20,000 Hertz (Hz) at the base of to 200Hz at the apex. After implantation, an audiologist individually adjusts stimulation levels of each electrode following which all electrodes are turned on such that the whole frequency spectrum of speech can be appreciated. This is known as "standard of care" (SOC) programming. While postoperative speech understanding is significantly better than preoperative levels, even the best performers complain that the fidelity of natural hearing is not reproduced. Additionally, a significant minority achieves poor outcomes despite normally functioning equipment for reasons that are unknown but likely relate to poor neural survival; however, this cannot be confirmed as postmortem histopathology is required to accurately document spiral ganglion cell count. In recent years much attention has focused on the interface between the cochlear implant electrodes and the auditory neurons they are stimulating. Technological improvements at Vanderbilt in imaging processing have made it possible to determine the location of each electrode array in relationship to the frequency spectrum of the cochlea. Using this information, the investigators have developed a new method of CI programming which they call image-guided cochlear implant programming, or IGCIP in which sub-optimally placed electrodes are turned-off or deactivated. Sub-optimally placed electrodes are defined as ones for which their neighboring electrodes are in closer proximity to the site of their neural stimulation. By deactivating sub-optimally positioned electrodes, channel interaction is reduced allowing a cleaner signal to be presented to the auditory nerve. The purpose of the study is to prospectively collect audiological outcomes on patients undergoing IGCIP. The investigators hypothesize that CI recipients will perform better with IGCIP as compared to SOC.
Cochlear implant recipients who have reached asymptotic improvement in performance with SOC will be offered enrollment. They will undergo post-operative CT scanning to determine the relationship between the cochlear implant electrodes and the neural interface. Recommendations regarding deactivation of sub-optimally placed electrodes will be communicated to the audiology team who, if in their clinical judgement deems deactivation of these electrodes reasonable, will implement the changes for a 1 month trial. The participant will return at 1 month to have audiological assessment as per the clinical standard of care. Based on these results, which will be shared with the patient, the patient can choose to use IGCIP or SOC for long term cochlear implant programming.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Tennessee
-
Nashville, Tennessee, United States, 37232
- Vanderbilt University Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Adults aged 18 to 90 years that have undergone diagnostic testing for sensorineural hearing loss and have received a cochlear implant with asymptotic improvement in performance with SOC programming will be considered eligible for the study.
Exclusion Criteria:
- Age < 18 years or > 90 years
- Non-English speaking (because our audiological speech testing battery is validated for English speakers)
- Pregnancy which is a contraindication for elective CT scanning and surgery
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Image-guided Cochlear Implant Programming (IGCIP)
Cochlear implant programming using IGCIP.
|
Post Cochlear Implant surgery, participant will receive traditional activation and programming per routine.
IGCIP will be used to offer alternative programming of the implant.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
AzBio Sentence Scores at +5 Signal to Noise Ratio (SNR)
Time Frame: Month 1 post cochlear implant activation
|
Month 1 post cochlear implant activation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Minimum Speech Test Battery
Time Frame: Month 1 post cochlear implant activation
|
Month 1 post cochlear implant activation
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Jack H. Noble, PhD, Vanderbilt University
- Study Chair: Rene H. Gifford, PhD, Vanderbilt University Medical Center
- Study Chair: Robert F. Labadie, MD, PhD, Vanderbilt University Medical Center
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 150417
- R01DC014037 (U.S. NIH Grant/Contract)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Cochlear Implant
-
NCT01737489Completed
-
NCT04320251Enrolling by invitationCochlear Implant
-
NCT02815124Withdrawn
-
NCT02966379Completed
-
NCT06142682RecruitingCochlear Implant
Clinical Trials on Image-Guided Cochlear Implant Programming
-
NCT02815124Withdrawn
-
NCT03694340CompletedChild | Deafness | Cochlear Implants | Hearing | Evoked Potentials, Auditory | Disabilities Hearing
-
NCT06734039Enrolling by invitationHearing Loss, Sensorineural | Hearing Loss, Unilateral | Cochlear Implants | Asymmetric Hearing Loss | Single-Sided Deafness (SSD)
-
NCT01460823Terminated
-
NCT07338864Not yet recruitingHearing Loss | Hearing Implants
-
NCT02309099CompletedMeniere's Disease | Unilateral Acoustic Neuroma
-
NCT05696171Recruiting
-
NCT05558514RecruitingHearing Loss, Sensorineural | Cochlear Implants