Effect of Kinesiotaping on Force Irradiation
The Determination of Relationship Between Kinesiotaping and Contralateral Force Irradiation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Fourty healthy subjects with no history of neurological or recent musculoskeletal injury will participate the study.
Healthy subjects are arranged in two groups of stimulation: kinesiotaping group (kinesiotaping and force irradiation) and control group (only force irradiation). The electromyographic response of the resting arm (non-dominant) will be assessed during the dominant arm movement for all subjects. Additionally, in kinesiotaping group, kinesiotaping will be applied 24 hours before the experiment.
The electromyographic response of the resting arm will be assessed under three contraction type movement (isometric, eccentric and concentric contractions) The SEMG signals are analysed by using MATLAB®, suitable signal proccessing techniques (linear envelope, Root Mean Square etc) are chosed. The statistical analysis are done by using SPSS®, according to data distribution, "Independent Sample T Test" or "Mann-Whitney U Test" is utilized for comparing outcomes of control and KT groups.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Istanbul, Turkey
- Bezmialem Vakıf University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- To be right-handed-dominant
- To have normal or corrected vision
- To have no formal history of any resistance training.
Exclusion Criteria:
- To have history of neurological or recent musculoskeletal injury
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Kinesiotaping Group
The group in which kinesiotaping is applied to non-dominant biceps brachii muscle of participants before 24 hours the force irradiation experiment.
|
For the force irradiation, while the subjects perform dominant elbow flexion at an angular velocity of 60°/s for concentric contractions, 30°/s for eccentric contractions, at 90° elbow flexion position for isometric contractions with a maximal effort level, electrical activity of the non-dominant biceps brachii and triceps brachii muscles are recorded.
For kinesiotaping, the elbow positioned in 30°-45° flexion and kinesiotaping facilitation technique is applied origin to insertion of non-dominant biceps brachii muscle before 24 hours the experiment.
Other Names:
|
|
Active Comparator: Control group
The group in which the participants only perform the the force irradiation experiment.
|
For the force irradiation, while the subjects perform dominant elbow flexion at an angular velocity of 60°/s for concentric contractions, 30°/s for eccentric contractions, at 90° elbow flexion position for isometric contractions with a maximal effort level, electrical activity of the non-dominant biceps brachii and triceps brachii muscles are recorded.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs isometric elbow flexion
Time Frame: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs isometric elbow flexion
Time Frame: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs concentric elbow flexion.
Time Frame: after inclusion
|
while the right elbow performs concentric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs concentric elbow flexion
Time Frame: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs eccentric elbow flexion
Time Frame: after inclusion
|
while the right elbow performs eccentric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs eccentric elbow flexion
Time Frame: after inclusion
|
while the right elbow performs eccentric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Measurement of the electromyographic activity of left biceps brachii muscle during left elbow maximum isometric flexion by using electromyography device.
Time Frame: after inclusion
|
Electromyographic activity of left elbow maximum isometric flexion is used for normalizing force irradiation data of left biceps brachii muscle
|
after inclusion
|
|
Measurement of the electromyographic activity of left triceps brachii muscle during left elbow maximum isometric extension by using electromyography device.
Time Frame: after inclusion
|
Electromyographic activity of left elbow maximum isometric extension is used for normalizing force irradiation data of left triceps brachii muscle
|
after inclusion
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Director: Aydın AKAN, Istanbul University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- hdenizkulli
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Healthy
-
NCT06818032RecruitingHealthy | Healthy Volunteers | Healthy Subjects | Healthy Volunteer | Healthy Adult | Healthy Volunteers Only | Healthy Male and Female Subjects | Healthy Non-smokers
-
NCT07232121RecruitingHealthy | Healthy Participants | Healthy Adult Females | Volunteer | Healthy Adult Male
-
NCT07197047CompletedHealthy | Healthy Volunteers | Healthy Subjects | Healthy Participants | Static Stretching | Stretch | Stretching
-
NCT05361343RecruitingHealthy Aging | Healthy Diet | Healthy Lifestyle
-
NCT05218980Not yet recruitingHealth-related Benefits of Introducing Table Olives Into the Diet of Young Adults: Olives For HealthHealthy Diet | Healthy Lifestyle | Healthy Nutrition | Cholesterol
-
NCT07515417Active, not recruitingHealthy | Healthy Participants | Healthy Adult | Healthy Women | Healthy Adult Females | Healthy Adult Participants | Healthy Young Adults | Healthy Adult Female Participants | Healthy Adult Male | Poor Sleep Quality
-
NCT03278535CompletedHealthy Volunteers | Healthy Subjects | Healthy Adults
-
NCT07520474CompletedHealthy Participants | Healthy Adult Participants | Healthy Young Adults
-
NCT07597928Not yet recruiting
-
NCT07285122RecruitingHealthy | Healthy Smoker
Clinical Trials on Force Irradiation
-
NCT01093014CompletedSpinal Cord Injuries
-
NCT04658940Completed
-
NCT04291443CompletedGingival Diseases | Tooth Diseases | Root Resorption | Orthodontic Appliance Complication | Orthodontic Pathological Resorption of External Root | Tooth Plaque
-
NCT02995616Completed
-
NCT03807349TerminatedIntracapsular Proximal Femur Fracture | Garden Grade I Subcapital Fracture of Femoral Neck | Garden Grade II Subcapital Fracture of Femoral Neck
-
NCT05018546CompletedSepsis | Urinary Tract Infections | Ureteric Injury
-
NCT03526198Completed