EFFEXTS OF THE CLEANSWEEP SUCTION CATHETER
EFFECTS OF TELEFLEX CATHETER (CLEANSWEEP) ON VENTILATOR MECHANICS
This study is designed to compare the effectiveness of a closed suction system with an inflatable balloon on the catheter (Cleansweep system) to that of a standard closed suction system in terms of reducing the interior resistance of endotracheal tubes. Subjects who require frequent suctioning ( > every 2.5 hours) and who have stable cardiovascular systems will be randomized to receive suctioning either through the Cleansweep system or standard system initially followed by the corresponding system. The subjects will be suctioned every two hours for eight hours ( the first 2 suction procedures with one system followed by 2 with the other system). After each suction procedure measurements of resistance will be made using peak and plateau pressures.
Analysis: For each patient, data for both procedures on each catheter system will be pooled and mean differences between the standard system and the Cleansweep system will be calculated. For all 20 patients the mean (+/- SD) of these differences will be calculated and significance will be sought using appropriate statistical tests. The study will be unblinded and randomization determines merely which system will used initially for the first 2 procedures.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
North Carolina
-
Durham, North Carolina, United States, 27710
- Duke Health System
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Intubated, mechanically ventilated patients who require suctioning more often than every 2.5 hours
Exclusion Criteria:
- Unstable cardiovascular system (significant arrythmias, blood pressure support requiring > 2 pressors
- refractory hypoxemia (P/F ratio < 80)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: CROSSOVER
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
OTHER: Cleansweep closed suction system
|
The Cleansweep closed suction system
|
|
OTHER: Halyard closed suction system
|
Halyard Closed Suction System
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in endotracheal tube resistance during mechanical ventilation after 4 suction procedures
Time Frame: 8 hours
|
Measurements of resistance will be made following each suction procedure (2 with the Cleansweep system and 2 with the standard system)
|
8 hours
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Neil MacIntyre, Duke University
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- Pro00087066
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Endotracheal Tube Clearance
-
NCT07017205Not yet recruitingMicroaspiration | Endotracheal Tube Cuff Pressure | Endotracheal Tube Cuff
-
NCT05034666Completed
-
NCT02407158TerminatedEndotracheal Tube Position
-
NCT01237756CompletedEndotracheal Tube Placement
-
NCT03385044Completed
-
NCT04503031CompletedEndotracheal Tube | Cuff Pressure
-
NCT01547507UnknownEndotracheal Tube | Mechanical Ventilation
-
NCT06939998Not yet recruitingEndotracheal Tube Placement
-
NCT07349953Completed
Clinical Trials on Cleansweep
-
NCT03868735CompletedMechanical Ventilation Complication