Ventilator-associated events (VAE) are a scourge of critical care settings and hospital systems at large. There is extensive evidence that ventilator-associated pneumonia (VAP) and related VAEs increase mortality rates in critically ill patients by up to 50%, while simultaneously increasing cost of care. C
Best-practice guidelines state that positioning ventilated patients at an angle between 30-45 degrees significantly reduces the potential for VAP and other VAE to develop. While the intent of the guidelines is to govern patient elevation angle, the lack of a mechanism to accurately measure patient elevation requires that nurses rely on the head-of-bed (HOB) protractor - a tool which reflects the angle of the bed, not the patient - to measure compliance. Depending upon the position and posture of the patient in the bed, a patient's elevation angle may be significantly different from the HOB angle. Critical care teams currently rely on built-in HOB protractors and digital inclinometers that measure the angle of the bed not the patient.
Angulus, LLC has developed a dual-component Angulus sensor to fill this gap in critical care technology. Angulus enables critical care practitioners to instantaneously understand a patient's elevation, identify when the patient is outside of the desired 30-45 degree recumbency scope, and efficiently correct the patient's orientation with immediate feedback. Angulus supports real-time minute-to-minute data display as well as longitudinal aggregation of data.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
New York
-
Bronx, New York, United States, 10461
- Montefiore Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Mechanical ventilation with any modality (e.g., endotracheal tube, tracheostomy)
- Age between 18 and 75 years
Exclusion Criteria:
- Patients with a known allergy to the encasing materials
- Patients who are advised to be positioned outside of the 30-45 degree scope.
Patients with any major chest wall abnormalities, or defects, including but not limited to:
- post-cardiac surgical patients
- pectus excavatum (or any congenital chest wall deformity)
- complicated skin and soft tissue infections on the chest wall
- heart-lung machine systems
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Feedback
The ICU with feedback will be equipped with display device corresponding to each Angulus device with an interactive software interface which displays the patient's elevation.
|
Feedback on patient recumbency
|
|
Other: No Feedback
The Angulus device will be on the patient but will NOT have the corresponding display data on patient elevation available to nurses.
|
Feedback on patient recumbency
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Compliance to Head of Bed Elevation to 30 Degree or More.
Time Frame: 3 months
|
Measured as a continuous variable between 0% and 100% compliance.
|
3 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Frequency That Patients in the ICU Are Rotated More Than 30 Degree Within 24 Hour Days and Association With Development of Decubitus Ulcers.
Time Frame: 3 months
|
As measured as categorical variable: incidence of decubitus ulcer
|
3 months
|
|
Frequency That Patients in the ICU Rotate More Than 30 Degree and Have Change in Elevation of More Than 15 Degree Within an Hour and Correlation With Agitation as Indicated by RASS.
Time Frame: 3 months
|
As measured by continuous variable
|
3 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Michelle Gong, MD, Einstein College of Medicine, Division of Critical Care
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 001 (Buy Pharma Ecza Deposu San. Tic. Ltd.)
- 1R43HL131177-01A1 (U.S. NIH Grant/Contract)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Hospital-acquired Pneumonia
-
NCT07512596Not yet recruitingHospital-acquired Bacterial Pneumonia/Ventilator-associated Bacterial Pneumonia
-
NCT07327619RecruitingHospital-acquired Bacterial Pneumonia and Ventilator-associated Bacterial Pneumonia
-
NCT06916481RecruitingCommunity Acquired or Acquiring Hospital Acquired Pneumonia
-
NCT06867458CompletedHospital Acquired Pneumonia | Ventilator Acquired Pneumonia | Hospital Acquired Infections | Nasal Decolonization of Staphylococcus Aureus
-
NCT07011433Enrolling by invitationHospital Acquired Pneumonia | Community Acquired Pneumonia (CAP)
-
NCT03006679WithdrawnHospital-Acquired Bacterial Pneumonia | Ventilator-Associated Bacterial Pneumonia | Hospital-Acquired Pneumonia | Ventilator-Associated Pneumonia
-
NCT03439124CompletedCommunity-acquired Pneumonia (CAP) | Hospital-acquired Pneumonia (HAP)
-
NCT02203110UnknownCommunity Acquired Pneumonia | Ventilator Associated Pneumonia | Hospital Acquired Pneumonia
-
NCT02454114CompletedCommunity Acquired Pneumonia | Lower Respiratory Tract Infection | Hospital Acquired Pneumonia
-
NCT04774094CompletedHospital-Acquired Pneumonia
Clinical Trials on Angulus
-
NCT05819242CompletedRheumatoid Arthritis | Carpal Tunnel Syndrome
-
NCT06637761Not yet recruiting