Effects of Non-invasive Ventilation on Respiratory Mechanics and NRD in Patients With Stable COPD
Effects of Non-invasive Positive Pressure Ventilation at Different Pressure on Respiratory Mechanics and Neural Respiratory Drive(NRD)in Patients With Stable Chronic Obstructive Pulmonary Disease(COPD)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Liqing Wang, doctor
- Phone Number: +86-02062782339
- Email: wliqing07@gmail.com
Study Locations
-
-
Guangdong
-
Guangzhou, Guangdong, China, 510282
- Zhujiang Hospital,Southern Medical Universicity
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients with pulmonary function test of forced expiratory volume at one second (FEV1)/forced vital capacity(FVC) < 70% after inhalation of bronchial dilation agent. Patients in a clinically stable state.
Exclusion Criteria:
- Patients they had other respiratory diseases, or evidence of pneumothorax or mediastinal emphysema and pacemaker installed. Patients with acute cardiovascular event and severe cor pulmonale. Patients with poor compliance. An Other causes of diaphragmatic dysfunction.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: COPD Group
incremental pressure support
|
Inspiratory positive airway pressure (IPAP) gradually increases from 10 to 24 cm water column (cmH2O) with 2 water column (cmH2O) increments.
The expiratory positive airway pressure (EPAP) remains 4 water column (cmH2O), and each pressure level is maintained for 5 to 10 minutes.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diaphragmatic function
Time Frame: Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
Diaphragmatic function can be assessed by diaphragm electromyogram (EMGdi), which reflect the physiological activity of the diaphragm and indicate functional status of the central drive.
|
Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Respiratory pressure
Time Frame: Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
Respiratory pressure can be assessed by transdiaphragmatic pressure (Pdi).
|
Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
|
Respiratory volume
Time Frame: Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
Respiratory volume can be assessed by Tidal volume (VT).
|
Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
|
Degree of dyspnea
Time Frame: Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
Difference in the degree of dyspnea can be measured by Borg index.
|
Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Pulse oxygen saturation (SpO2)
Time Frame: Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
Change in SpO2 can be recorded by noninvasive monitoring instruments.
|
Change from baseline in diaphragm electromyogram at the pressure of 10cm water column (cmH2O). (5minutes later, 10 minutes later, 15 minutes later, 20 minutes later, 25 minutes later, 30 minutes later, 35 minutes later)
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Xin Chen, doctor, Zhujiang Hospital,Southern Medical Unversity
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2018-HXNK-010
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.