Root Proximity During Mini-Screw Insertion Using a Digital Three-Dimensional Printed Guide
Evaluation of Root Proximity During Mini-Screw Insertion Using a Digital Three-Dimensional Printed Guide Versus Conventional Free Hand Placement Technique in Adult Orthodontic Patients A Split Mouth Randomized Clinical Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
PICOs P: Adult orthodontic patients need mini screws in maxillary arch bilaterally for anchorage I: Three dimensional printed digital guide for mini screw insertion C: Conventional free hand insertion technique
- O: Primary outcome: Root proximity
Secondary outcomes:
- Patient discomfort during insertion 17
- Insertion accuracy
- Angular deviation
- Linear deviation
- Failure 18 S: Split Mouth Randomized clinical Trial
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Hadir Abo shady, MD
- Phone Number: 00201001937931
- Email: hadiraboshady@gmail.com
Study Contact Backup
- Name: Mai Abo El fotouh, PHD
- Phone Number: 01001884499
- Email: maihamdi@gmail.com
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Orthodontic patients with Angle's Class I bimaxillary protrusion • Patients having average mandibular plane angle
Exclusion Criteria:
Mixed dentition patients
- Smoker patients
- Patients with Increased lower facial height
- Patients with missing posterior teeth
- Bleeding disorders or anticoagulant therapy
- Patients with cleft lip & palate
- Patients with facial asymmetry
- Patients with transverse maxillary deficiency
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Three dimensional printed digital guide
one mini-screw will be inserted in the buccal interradicular space between upper second premolar and first molar using Three dimensional printed digital guide, which is a device deisgned and printed through CAD/CAM technology, it's a printed plate fit on the teeth and buccal mucosa with a channel for mini- screw insertion, mini-screw will be inserted through the plate's channel
|
A CAD/CAM printed plate with a channel for mini-screw insertion
Other Names:
|
|
No Intervention: Conventional free hand insertion
one mini-screw will be inserted in the buccal interradicular space between upper second premolar and first molar using conventional free hand insertion of mini-screw, which is a technique using the guiding anatomy for mini-screw insertion using the driver and the operator's skill.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Root proximity
Time Frame: immediately after mini-screw insertion (T0)
|
Distance between inserted mini screw and the adjacent roots in microns
|
immediately after mini-screw insertion (T0)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Patient discomfort:
Time Frame: immediately after mini-screw insertion (T0)
|
Likert scale, it is scale divided into five points to measure the degree of patient discomfort maximum value(5) strongly discomfort, discomfort, neutral, little discomfort, and minimum value (0)no discomfort
|
immediately after mini-screw insertion (T0)
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Bae MJ, Kim JY, Park JT, Cha JY, Kim HJ, Yu HS, Hwang CJ. Accuracy of miniscrew surgical guides assessed from cone-beam computed tomography and digital models. Am J Orthod Dentofacial Orthop. 2013 Jun;143(6):893-901. doi: 10.1016/j.ajodo.2013.02.018.
- Suzuki EY, Suzuki B. Accuracy of miniscrew implant placement with a 3-dimensional surgical guide. J Oral Maxillofac Surg. 2008 Jun;66(6):1245-52. doi: 10.1016/j.joms.2007.08.047.
Study record dates
Study Major Dates
Study Start (Anticipated)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- CEBD-CU-2018-08-27
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.