Acute Assessment of a Micro Multipolar Lead for Enhanced Cardiac Resynchronisation Therapy (AXONE-Acute)
AXONE -Acute : Acute Assessment of a Micro Multipolar Lead for Enhanced Cardiac Resynchronisation Therapy
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Bordeaux, France
- Bordeaux University Hospital
-
Lille, France
- Lille University Hospital
-
Rennes, France
- Rennes University Hospital
-
Rouen, France
- Rouen University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Male or female patient aged ≥18 years old.
- Patient presenting a CRT-P or CRT-D indication according to the latest ESC guidelines .
- Primary implant of a CRT device (including upgrade from a single or dual-chamber pacemaker or ICD).
- Signed and dated informed consent.
- Patient affiliated with, or beneficiary of a social security category.
Exclusion Criteria:
- Class IV of NYHA (ambulatory or not).
- Allergy to contrast media used for imaging during cardiac catheterization.
- Severe Renal Failure (clearance of creatinine < 30ml/mn/m²).
- Previous failure catheterization of the coronary sinus, or previous failure of left ventricular lead implantation.
- Already included in another clinical study involving intra-cardiac active implantable device, or participation to any other clinical trial in the last 2 weeks.
- Person deprived of liberty by administrative or judicial decision or placed under judicial protection (guardianship or supervision).
- Known pregnancy, breastfeeding women or in childbearing age without an adequate contraceptive method (failure rate < 1%).
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Implant test procedure
Implant test procedure with new LV quadripolar lead before a standard implantation for Cardiac resynchronisation therapy
|
Implant test procedure with new LV quadripolar lead before a standard implantation for Cardiac resynchronisation therapy
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
LV Multizone pacing success rate
Time Frame: 20 min
|
Percent of patients where the placement of the AXONE lead provides two distant LV pacing vectors matching Pacing Threshold ≤ 3.5V/0.5ms
|
20 min
|
|
LV pacing success rate
Time Frame: 20 min
|
Percent of patients where the placement of the AXONE lead allows at least one LV pacing vector matching Pacing Threshold ≤ 3.5V/0.5ms
|
20 min
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Implant testing Procedure-related Adverse Events procedure.
Time Frame: 1 month post testing
|
1 month post testing
|
|
|
Electrical performance of device (1)
Time Frame: 20 min
|
Electrical performance focusing on LV pacing threshold (Volts)
|
20 min
|
|
Electrical performance of device (2)
Time Frame: 20 min
|
Electrical performance focusing on LV pacing impedance (Ohm)
|
20 min
|
|
Lead Implant Efficiency
Time Frame: 20 min
|
procedure time for successful placement
|
20 min
|
|
Lead Implant Efficiency
Time Frame: 20 min
|
Radiation dose during implant
|
20 min
|
|
Satisfaction of implanter
Time Frame: 20 min
|
handling assessment of implanter using satisfaction scale
|
20 min
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Frédéric ANSELME, Pr, University Hospital, Rouen
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 2017/170/HP
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Cardiac Resynchronisation Therapy
-
NCT04156412CompletedCardiac Resynchronisation Therapy
-
NCT07492979Not yet recruitingConduction System Pacing vs. Biventricular Pacing for Cardiac Resynchronization Therapy (Nordic-CSP)Heart Failure | Conduction System Pacing | Cardiac Resynchronisation Therapy (CRT)
-
NCT02814942RecruitingHeart Failure | Cardiac Resynchronisation Therapy
-
NCT07084467Not yet recruitingHeart Failure | Cardiac Resynchronisation Therapy (CRT)
-
NCT07254013RecruitingBradycardia | Left Bundle Branch Area Pacing | ECG | Cardiac Resynchronisation Therapy (CRT)
-
NCT04376983RecruitingHeart Failure | Telemedicine | Cardiac Resynchronisation Therapy
-
NCT07253909Enrolling by invitationHeart Failure | Implantable Cardioverter Defibrillator (ICD) | Reduced Ejection Fraction Heart Failure | Cardiac Resynchronisation Therapy (CRT)
-
NCT00472238UnknownHeart Failure | Sudden Cardiac Death | Cardiac Resynchronisation Therapy
-
NCT07469137Active, not recruitingHearth Failure With Reduced Ejection Fraction (HFrEF) | Left Branch Bundle Block | Cardiac Resynchronisation Therapy (CRT)
-
NCT01055210CompletedHeart Failure | Cardiac Resynchronisation Pacemakers
Clinical Trials on Implant test procedure
-
NCT04156412CompletedCardiac Resynchronisation Therapy
-
NCT01949324CompletedMacular Telangiectasia Type 2
-
NCT00956384Completed
-
NCT02404649CompletedPartial Edentulism | Atrophy of Edentulous Alveolar Ridge
-
NCT04424342CompletedDentist-Patient Relations
-
NCT04215575CompletedGlaucoma, Open-Angle | Glaucoma, Angle-Closure | Glaucoma, Neovascular | Glaucoma Secondary
-
NCT00283738UnknownMigraine | Patent Foramen Ovale | Aura
-
NCT06408506Completed