Comparison Between Injection Molded Polyetheretherketone (PEEK) Framework and Cobalt Chromium Framework Removable Partial Dentures Regarding Periodontal Health of Abutment Teeth
Evaluation of Periodontal Health of the Abutment Teeth in Partial Dentures Made of Injection Molded PEEK Framework Versus Cobalt Chromium Framework in Mandibular Kennedy Class I Edentulous Cases
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Amr Ha Mohammed, master
- Phone Number: +201001600625
- Email: amr_hatim@yahoo.com
Study Contact Backup
- Name: Ahmed He Zidan, master
- Phone Number: +201126534668
- Email: ahmedhefnyf@gmail.com
Study Locations
-
-
-
Cairo, Egypt, 11311
- Faculty of Oral and Dental Medicine Cairo University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Kennedy Class I partially edentulous subjects indicated for framework partial denture
Exclusion Criteria:
- 1- uncooperative patients . 2- bad oral hygiene patients .
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: cobalt-chromium framework partial dentures
It's the gold standard biocompatible metal alloy used in thin sections, provide high strength and stiffness ,conduct heat and cold for a more natural experience, and is resistant to corrosion but their disadvantages include esthetic issues with metal display, oral galvanism, adverse tissue reactions,and osteolysis of abutment teeth.
|
It's a biocompatible metal alloy used in thin sections and are less bulky, provide high strength and stiffness ,conduct heat and cold for a more natural experience, enable designs that minimize the covering of the gingival margins, allow for a stable denture base, and is resistant to corrosion.
Disadvantages include hypersensitivity, esthetic issues with metal display, oral galvanism, adverse tissue reactions, osteolysis of abutment teeth, and biofilm production .
|
|
Experimental: PEEK framework partial dentures
It's a promising polymer-based framework has recently been introduced which is made of polyetheretherketone polymer frame combined with acrylic resin denture teeth and a conventional acrylic resin denture base.
|
It's a promising polymer-based framework material has recently been introduced which is made of polyetheretherketone polymer frame combined with acrylic resin denture teeth and a conventional acrylic resin denture base.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Periodontal status
Time Frame: Change in periodontal status will be assessed at base line , after one month and after 3 months .
|
periodontal status of the abutment teeth assessed by a periodontal chart .
|
Change in periodontal status will be assessed at base line , after one month and after 3 months .
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Abdel-Bary SK, Rostom EM, Elboarey AN. Thermoplastic Removable Partial Dentures versus Metal Cobalt-Chromium. RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES. 2016 Jul 1;7(4):464-70.
Study record dates
Study Major Dates
Study Start (Anticipated)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CEBD-CU-2018-11-28
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.