tSMS in Essential Tremor
Transcranial Static Magnetic Field Stimulation (tSMS) in Essential Tremor
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 2
Contacts and Locations
Study Locations
-
-
Madrid
-
Móstoles, Madrid, Spain, 28938
- CINAC, Hospital Universitario Puerta del Sur
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Essential tremor
Exclusion Criteria:
- MRI-incompatible metal objects in the body (e.g. cardiac pacemakers)
- other main neuropsychiatric co-morbidity
- pregnancy
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Triple
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: tSMS left motor cortex (sham right)
30 min of tSMS applied to the left motor cortex with sham on the right motor cortex
|
Transcranial static magnetic field stimulation (tSMS) is a non-invasive brain stimulation (NIBS) technique that decreases cortical excitability (Oliviero et al., 2011; Oliviero et al., 2015; Dileone et al., 2018).
Static magnetic fields suitable for tSMS are obtained with commercially available neodymium magnets.
We will use a cylindrical neodymium magnet of 45 mm diameter and 30 mm of thickness, with a weight of 360 g (MAG45r; Neurek SL, Toledo, Spain), which will be applied with south polarity to the left or right motor cortex, using a tSMS helmet (MAGmv1.0;
Neurek SL, Toledo, Spain).
Other Names:
A non-magnetic metal cylinder, with the same size, weight and appearance of the magnet, will be used for sham stimulation (MAG45s; Neurek SL, Toledo, Spain) of motor cortex contralateral to the stimulated hemisphere.
Other Names:
|
|
Experimental: tSMS right motor cortex (sham left)
30 min of tSMS applied to the right motor cortex with sham on the left motor cortex
|
Transcranial static magnetic field stimulation (tSMS) is a non-invasive brain stimulation (NIBS) technique that decreases cortical excitability (Oliviero et al., 2011; Oliviero et al., 2015; Dileone et al., 2018).
Static magnetic fields suitable for tSMS are obtained with commercially available neodymium magnets.
We will use a cylindrical neodymium magnet of 45 mm diameter and 30 mm of thickness, with a weight of 360 g (MAG45r; Neurek SL, Toledo, Spain), which will be applied with south polarity to the left or right motor cortex, using a tSMS helmet (MAGmv1.0;
Neurek SL, Toledo, Spain).
Other Names:
A non-magnetic metal cylinder, with the same size, weight and appearance of the magnet, will be used for sham stimulation (MAG45s; Neurek SL, Toledo, Spain) of motor cortex contralateral to the stimulated hemisphere.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Change from baseline in postural tremor amplitude in the hand contralateral to hemispheren that received tSMS treatment compared to the hand contralateral to the hemisphere that received sham treatment, as measured by accelerometry.
Time Frame: Immediately after treatment compared baseline
|
Immediately after treatment compared baseline
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Change from baseline in postural tremor amplitude 15 minutes after treatment, as measured by accelerometry.
Time Frame: 15 minutes after treatment compared to baseline
|
15 minutes after treatment compared to baseline
|
|
Change from baseline in rest tremor amplitude, as measured by accelerometry.
Time Frame: Immediately after treatment and 15 minutes after treatment compared baseline.
|
Immediately after treatment and 15 minutes after treatment compared baseline.
|
|
Change from baseline in tremor frequency, as measured by accelerometry.
Time Frame: Immediately after treatment and 15 minutes after treatment compared baseline.
|
Immediately after treatment and 15 minutes after treatment compared baseline.
|
|
Change from baseline in the Clinical Rating Scale for Tremor part B (drawing)
Time Frame: 5 minutes after treatment and 20 minutes after treatment compared to baseline
|
5 minutes after treatment and 20 minutes after treatment compared to baseline
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Oliviero A, Mordillo-Mateos L, Arias P, Panyavin I, Foffani G, Aguilar J. Transcranial static magnetic field stimulation of the human motor cortex. J Physiol. 2011 Oct 15;589(Pt 20):4949-58. doi: 10.1113/jphysiol.2011.211953. Epub 2011 Aug 1.
- Oliviero A, Carrasco-Lopez MC, Campolo M, Perez-Borrego YA, Soto-Leon V, Gonzalez-Rosa JJ, Higuero AM, Strange BA, Abad-Rodriguez J, Foffani G. Safety Study of Transcranial Static Magnetic Field Stimulation (tSMS) of the Human Cortex. Brain Stimul. 2015 May-Jun;8(3):481-5. doi: 10.1016/j.brs.2014.12.002. Epub 2014 Dec 11.
- Dileone M, Mordillo-Mateos L, Oliviero A, Foffani G. Long-lasting effects of transcranial static magnetic field stimulation on motor cortex excitability. Brain Stimul. 2018 Jul-Aug;11(4):676-688. doi: 10.1016/j.brs.2018.02.005. Epub 2018 Feb 7.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Fundacion de Investigación HM
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.