Clinical Trial to Improve the Magnetic Levator Prosthesis
Clinical Trial to Improve the Magnetic Levator Prosthesis (MLP) Including the Development and Testing of a Novel Adjustable Force System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Massachusetts
-
Boston, Massachusetts, United States, 02114
- Schepens Eye Research Institute
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Experimental:
- Presence of ptosis for at least one eye which obscures the visual axis in the resting position (without frontalis drive, lifting with forehead muscles)
- Moderate cognitive function or better defined as greater than or equal to 18 out of 30 on a pre-screening of the Mini-Mental State Exam
- Age 5 or older
Exclusion Criteria:
- Experimental:
- Absence of blepharoptosis or presence of a corneal ulcer.
- Those with a corneal ulcer are at risk for permanent loss of vision and should be managed with proven methods.
- Age less than 5,
- Severe Cognitive impairment defined as MMSE score <18, behaviors consistent with delirium (combinations of disorientation, hallucinations, delusions, and incoherent speech), or lethargy. These individuals must be excluded since participation requires competent self-care, reliable responses and cooperation during fitting of the devices.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Non-Randomized
- Interventional Model: Crossover Assignment
- Masking: Triple
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
No Intervention: Experimental Group baseline
Subjects with ptosis had their interpalpebral fissure measured continuously for 1 minute with no device.
|
|
|
Experimental: Experimental Group MLP 0 degree orientation
Subjects with ptosis had their interpalpebral fissure measured continuously for 1 minute with the MLP set at 0 degrees polarization angle.
|
Neodymium magnet embedded in a glasses frame and a polymer embedded (PDMS) micro-magnet array fitted externally to the upper lid with IV 3000 securement film.
The IV 3000 is FDA approved for extended wear on the skin.
Tegaderm, which is essentially the same adhesive, is even FDA approved as an eye covering (we used Tegaderm in early studies but switched to IV 3000 for its superior ease of handling based on packaging technique).
|
|
Experimental: Experimental Group MLP 30 Degree Orientation
Subjects with ptosis had their interpalpebral fissure measured continuously for 1 minute with the MLP set at 30 degrees polarization angle.
|
Neodymium magnet embedded in a glasses frame and a polymer embedded (PDMS) micro-magnet array fitted externally to the upper lid with IV 3000 securement film.
The IV 3000 is FDA approved for extended wear on the skin.
Tegaderm, which is essentially the same adhesive, is even FDA approved as an eye covering (we used Tegaderm in early studies but switched to IV 3000 for its superior ease of handling based on packaging technique).
|
|
Experimental: Experimental Group MLP 60 Degree Orientation
Subjects with ptosis had their interpalpebral fissure measured continuously for 1 minute with the MLP set at 60 degrees polarization angle.
|
Neodymium magnet embedded in a glasses frame and a polymer embedded (PDMS) micro-magnet array fitted externally to the upper lid with IV 3000 securement film.
The IV 3000 is FDA approved for extended wear on the skin.
Tegaderm, which is essentially the same adhesive, is even FDA approved as an eye covering (we used Tegaderm in early studies but switched to IV 3000 for its superior ease of handling based on packaging technique).
|
|
Experimental: Experimental Group MLP 90 Degree Orientation
Subjects with ptosis had their interpalpebral fissure measured continuously for 1 minute with the MLP set at 90 degrees polarization angle.
|
Neodymium magnet embedded in a glasses frame and a polymer embedded (PDMS) micro-magnet array fitted externally to the upper lid with IV 3000 securement film.
The IV 3000 is FDA approved for extended wear on the skin.
Tegaderm, which is essentially the same adhesive, is even FDA approved as an eye covering (we used Tegaderm in early studies but switched to IV 3000 for its superior ease of handling based on packaging technique).
|
|
Experimental: Experimental Group MLP 180 Degree Orientation
Subjects with ptosis had their interpalpebral fissure measured continuously for 1 minute with the MLP set at 180 degrees polarization angle.
|
Neodymium magnet embedded in a glasses frame and a polymer embedded (PDMS) micro-magnet array fitted externally to the upper lid with IV 3000 securement film.
The IV 3000 is FDA approved for extended wear on the skin.
Tegaderm, which is essentially the same adhesive, is even FDA approved as an eye covering (we used Tegaderm in early studies but switched to IV 3000 for its superior ease of handling based on packaging technique).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in Interpalpebral Fissure During Eye Opening
Time Frame: 6 minutes, 1 minute for each rotation position.
|
Change in interpalpebral fissure (resting open) at 5 different force settings of the rotatable adjustable force system.
|
6 minutes, 1 minute for each rotation position.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in interpalpebral fissure during the blink
Time Frame: Video recording will be performed 7 times for the duration of the study (4 videos performed during visit 1; 3 video performed during visit 2)
|
Video analysis to measure the completeness of eye closure with the MLP compared to 1) no device, 2) relative to the contralateral side (if normal), 3) relative to different configurations of the device and custom vs. non-custom frames.
|
Video recording will be performed 7 times for the duration of the study (4 videos performed during visit 1; 3 video performed during visit 2)
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Kevin Houston, OD, M. Sc., UMass Chan Medical School
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Brain Diseases
- Central Nervous System Diseases
- Nervous System Diseases
- Wounds and Injuries
- Neoplasms by Site
- Neoplasms
- Neuromuscular Diseases
- Autoimmune Diseases
- Immune System Diseases
- Eye Diseases
- Autoimmune Diseases of the Nervous System
- Neurodegenerative Diseases
- Paraneoplastic Syndromes, Nervous System
- Nervous System Neoplasms
- Paraneoplastic Syndromes
- Neuromuscular Junction Diseases
- Craniocerebral Trauma
- Trauma, Nervous System
- Eyelid Diseases
- Brain Injuries, Traumatic
- Brain Injuries
- Myasthenia Gravis
- Blepharoptosis
Other Study ID Numbers
Other Study ID Numbers
- 18-166H
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.