Ventilatory Adaptation to Concentric Versus Eccentric Exercise in Patients With Severe COPD (CONvEX)
Pulmonary rehabilitation (PR) based on concentric exercise training has become an integral component in the treatment of patients with chronic obstructive pulmonary disease (COPD), improving functional capacities while diminishing symptoms and improving quality of life.
However, the response to concentric exercise training is heterogeneous from one COPD patient to another. The inability of some COPD patients to achieve the exercise intensities required to stress limb muscles due to severe ventilatory limitation could partially explain their poor response to training.
Endurance exercise with eccentric muscle contractions could be an interesting alternative to concentric exercise because it produces greater muscle force through its lower metabolic cost. Eccentric exercise could allow patients with severe airflow limitation to perform prolonged exercise sessions with sufficient intensity to improve muscle function.
Nevertheless, a recent study performed in healthy young subjects reported that eccentric exercise induced a more hyperpneic breathing pattern (i.e., lower tidal volume and higher breathing frequency) that concentric for a given minute ventilation.
The main objective of CONvEX study is to compare ventilatory adaptation between two modalities of exercise performed on cycle ergometer (concentric versus eccentric) in severe COPD patients.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Pulmonary rehabilitation (PR) based on concentric exercise training has become an integral component in the treatment of patients with chronic obstructive pulmonary disease (COPD), improving functional capacities while diminishing symptoms and improving quality of life.
However, the response to concentric exercise training is heterogeneous from one COPD patient to another. The inability of some COPD patients to achieve the exercise intensities required to stress limb muscles due to severe ventilatory limitation could partially explain their poor response to training.
Endurance exercise with eccentric muscle contractions could be an interesting alternative to concentric exercise because it produces greater muscle force through its lower metabolic cost. Eccentric exercise could allow patients with severe airflow limitation to perform prolonged exercise sessions with sufficient intensity to improve muscle function.
Nevertheless, a recent study performed in healthy young subjects reported that eccentric exercise induced a more hyperpneic breathing pattern (i.e., lower tidal volume and higher breathing frequency) that concentric for a given minute ventilation.
The main objective of CONvEX study is to compare ventilatory adaptation between two modalities of exercise performed on cycle ergometer (concentric versus eccentric) in severe COPD patients.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Besançon, France, 25000
- CHU De Besancon
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Severe COPD (FEV1 [forced expiratory volume in 1 second] / FVC [forced vital capacity] < 70% et FEV1 < 50%)
- Informed consent
- Affiliation to a social security scheme
Exclusion Criteria:
- Effort oxygen therapy
- Cardiovascular, neuromuscular or musculoskeletal disorders that can provide significant dyspnea or limit exercise
- Legal incapacity
- Low or no cooperation anticipated
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Concentric-eccentric
|
Patients will perform incremental exercise test on semi recumbent eccentric ergometer
|
|
Experimental: Eccentric-concentric
|
Patients will perform incremental exercise test on semi recumbent concentric ergometer
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Ventilatory adaptation
Time Frame: week 1
|
Breathing frequency/tidal volume ratio at the maximum common minute ventilation.
|
week 1
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Dynamic hyperinflation
Time Frame: week 1
|
Dynamic hyperinflation will be assessed through iterative inspiratory capacity (IC) measurment during exercise.
A decrease in IC >150 mL compared to resting levels at any time point during exercise will be considered as dynamic hyperinflation.
|
week 1
|
|
Brachial muscle enrollment
Time Frame: week 1
|
2.4 GHz electromyographic activity of biceps brachii recorded using surface electrod (Cometa Wave Plus wireless EMG)
|
week 1
|
|
Quadriceps muscle enrollment
Time Frame: week 1
|
2.4 GHz electromyographic activity of vastus lateralis recorded using surface electrod (Cometa Wave Plus wireless EMG)
|
week 1
|
|
Ventilatory efficiency
Time Frame: week 1
|
Dead volume/Tidal volume ratio
|
week 1
|
|
Ventilatory efficiency
Time Frame: week 1
|
Minute ventilation/Carbon dioxide production ratio
|
week 1
|
|
Tolerance
Time Frame: week 1
|
Borg modified scale [ranging from 0 to 10] for dyspnoea 0 indicates no dyspnoea and 10 the maximum dyspnoea
|
week 1
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- P/2018/374
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.