Impact of Pacing Mode and Diastolic Function on Cardiac Output (PADIAC)
Background It is known from previous research that in patients with complete AV (atrioventricular) block and pacemaker stimulation stroke volume and cardiac output are higher with AV-synchronous than with AV-dyssynchronous pacing. However, the extent to which patients profited from AV-synchronous stimulation varied substantially.
Aim of the study Aim of this study is to systematically analyze the impact of diastolic function and other echo parameters on the difference of stroke volumes/cardiac output between AV-synchronous and AV-dyssynchronous pacing modes.
Methods Patients fulfilling the entry criteria will be enrolled (two-chamber pacemaker of any vendor eligible) in this monocentric, prospective, interventional study. Baseline data will be collected with a standardized questionnaire. During an echo examination, parameters of diastolic, systolic and atrial function will be assessed. Then, the stroke volume/cardiac output will be measured twice in each patient, once with AV-synchronous and once with AV-dyssynchronous pacing. Therefore, each patient will represent their own control. It will be randomized (coin tossing) which stimulation mode is first and which is second (sonographer and patient will be blinded). Descriptive statistics will be applied and regression models will be fitted to explore the data.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Upper Austria
-
Linz, Upper Austria, Austria, 4020
- Kepler University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patient is able and willing to give informed consent and is above the age of 18.
- Patient is implanted with a dual chamber pacemaker system for at least 6 weeks.
- Patient is in sinus rhythm on the day of recruitment.
- Patient has a ventricular pacing rate exceeding 90%.
- Upon initial device interrogation, parameters are within normal ranges.
- Calculated battery life is more than 1 year.
Exclusion Criteria:
- Patient is not in sinus rhythm on the day of echo examination.
- Intrinsic ventricular activation on the day of echo examination.
- Relevant shunt on the atrial, ventricular or pulmonary level.
- Moderate or severe heart valve dysfunction (stenosis or regurgitation).
- Presence of other medical devices that may interact with the pacemaker system.
- Women who are pregnant or breast feeding.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Eligible patients - pacing mode sequence 1
Echo assessment of parameters of diastolic function, systolic function, and atrial function.
Then, the stroke volume and cardiac output are measured during AV-asynchronous and AV-synchronous pacemaker stimulation: AV-synchronous pacing mode first, then AV-dyssynchronous pacing mode.
|
Echocardiographic indices are measured during AV asynchronous and AV synchronous pacemaker stimulation.
|
|
Experimental: Eligible patients - pacing mode sequence 2
Echo assessment of parameters of diastolic function, systolic function, and atrial function.
Then, the stroke volume and cardiac output are measured during AV-asynchronous and AV-synchronous pacemaker stimulation: AV-dyssynchronous pacing mode first, then AV-synchronous pacing mode.
|
Echocardiographic indices are measured during AV asynchronous and AV synchronous pacemaker stimulation.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Effect of left ventricular diastolic function on the change of cardiac output between AV-synchronous and AV-asynchronous pacing modes.
Time Frame: During echo examination.
|
Echo parameters of diastolic function.
|
During echo examination.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Effect of left ventricular systolic function on the change of cardiac output between AV-synchronous and AV-asynchronous pacing modes.
Time Frame: During echo examination.
|
Echo parameters of systolic function.
|
During echo examination.
|
|
Effect of atrial function on the change of cardiac output between AV-synchronous and AV-asynchronous pacing modes.
Time Frame: During echo examination.
|
Echo parameters of atrial function.
|
During echo examination.
|
|
Effect of baseline characteristics on the change of cardiac output between AV-synchronous and AV-asynchronous pacing modes.
Time Frame: During echo examination.
|
Demographic variables and co-morbidities.
|
During echo examination.
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Clemens Steinwender, Assoc. Prof., MD, Kepler University Hospital, Department of Cardiology
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 01/2019
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Diastolic Function
-
NCT07157527Not yet recruitingLeft Ventricular Diastolic Function
-
NCT02714244CompletedLeft Ventricular Function Diastolic Dysfunction | Fluid Responsiveness
-
NCT04474639CompletedDiastolic Function
-
NCT02138903CompletedCritical Care | Diastolic Function | Weaning of Mechanical Ventilation | Trans-thoracic Echocardiography | Mitral Doppler
-
NCT01504828CompletedLeft Ventricular Function Systolic Dysfunction | Left Ventricular Function Diastolic Dysfunction | Ageing
-
NCT05726474CompletedHeart Failure | Exercise Capacity | Diastolic Function | Endothelial Function | Arterial Stiffness | Physical Exercise
-
NCT01252238TerminatedInsulin Sensitivity | Diastolic Function | Aortic Compliance
-
NCT00846404UnknownDiastolic Heart Failure | Diastolic Dysfunction
-
NCT07331233Not yet recruiting
-
NCT03586414Active, not recruitingDiastolic Dysfunction
Clinical Trials on Pacemaker stimulation mode
-
NCT05839730RecruitingHeart Failure With Preserved Ejection Fraction | Concentric Hypertrophy
-
NCT02186314Unknown
-
NCT03301571CompletedRight Ventricular Dysfunction
-
NCT01497639Completed
-
NCT03318172Terminated
-
NCT01798043TerminatedHeart Block | Ventricular Dysfunction | Atrioventricular Block | Sick Sinus Syndrome
-
NCT01803217CompletedPacemaker Implantation for Sinus Node Disease
-
NCT03390192Completed
-
NCT05626608Recruiting