The Effect of Different Measurement-manufacturing Techniques on Load Distribution in Amputees
The Effect of Different Measurement-manufacturing Techniques on Stump and Soles Load Distribution in Transtibial Knee Prostheses
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Istanbul, Turkey, 34000
- Marmara University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Being unilateral transtibial amputation
- To have enough perception level to understand and apply commands
Exclusion Criteria:
- To have orthopedic, neurological, etc. disorder other than amputation that will affect posture or gait
- The presence of pain that will affect the posture or walking pattern
- Wound / tenderness on the stump
- Visual impairment that will affect the posture or gait pattern
- Use of any assistive device (walking stick, canary, etc.) during walking
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Group 1
Unilateral transtibial amputees using conventinional manufactured socket
|
Presssure disturubition will be measured in conventional manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
|
Group 2
Unilateral transtibial amputees using 3D manufactured socket
|
Presssure disturubition will be measured in 3D manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Measurement of load distrubution on stump in conventional manufactured socket
Time Frame: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in 3D manufactured socket
Time Frame: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in conventional manufactured socket
Time Frame: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
|
Measurement of load distrubution on stump in 3D-manufactured socket
Time Frame: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Time Frame: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Time Frame: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Time Frame: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Time Frame: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: yasar tatar, Marmara University
Publications and helpful links
General Publications
- Dou P, Jia X, Suo S, Wang R, Zhang M. Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. Clin Biomech (Bristol, Avon). 2006 Dec;21(10):1067-73. doi: 10.1016/j.clinbiomech.2006.06.004. Epub 2006 Aug 17.
- Jia X, Suo S, Meng F, Wang R. Effects of alignment on interface pressure for transtibial amputee during walking. Disabil Rehabil Assist Technol. 2008 Nov;3(6):339-43. doi: 10.1080/17483100802044634.
- Xiaohong J, Xiaobing L, Peng D, Ming Z. The Influence of Dynamic Trans-tibial Prosthetic Alignment on Standing Plantar Foot Pressure. Conf Proc IEEE Eng Med Biol Soc. 2005;2005:6916-8. doi: 10.1109/IEMBS.2005.1616096.
- Lee VS, Solomonidis SE, Spence WD. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study. Proc Inst Mech Eng H. 1997;211(2):167-80. doi: 10.1243/0954411971534287.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 09.2019.359
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.