The Effect of Different Measurement-manufacturing Techniques on Load Distribution in Amputees
The Effect of Different Measurement-manufacturing Techniques on Stump and Soles Load Distribution in Transtibial Knee Prostheses
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Typ studie
Typ studie
Zápis (Očekávaný)
Zápis
Kontakty a umístění
Studijní místa
-
-
-
Istanbul, Krocan, 34000
- Marmara University
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Being unilateral transtibial amputation
- To have enough perception level to understand and apply commands
Exclusion Criteria:
- To have orthopedic, neurological, etc. disorder other than amputation that will affect posture or gait
- The presence of pain that will affect the posture or walking pattern
- Wound / tenderness on the stump
- Visual impairment that will affect the posture or gait pattern
- Use of any assistive device (walking stick, canary, etc.) during walking
Studijní plán
Jak je studie koncipována?
Detaily designu
Počet skupin / kohort
Kohorty a intervence
Skupina / kohortaSkupina / kohorta |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Group 1
Unilateral transtibial amputees using conventinional manufactured socket
|
Presssure disturubition will be measured in conventional manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
|
Group 2
Unilateral transtibial amputees using 3D manufactured socket
|
Presssure disturubition will be measured in 3D manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Measurement of load distrubution on stump in conventional manufactured socket
Časové okno: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in 3D manufactured socket
Časové okno: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in conventional manufactured socket
Časové okno: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
|
Measurement of load distrubution on stump in 3D-manufactured socket
Časové okno: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Časové okno: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Časové okno: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Časové okno: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Časové okno: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Vyšetřovatelé
Vyšetřovatelé
- Ředitel studie: yasar tatar, Marmara University
Publikace a užitečné odkazy
Obecné publikace
- Dou P, Jia X, Suo S, Wang R, Zhang M. Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. Clin Biomech (Bristol, Avon). 2006 Dec;21(10):1067-73. doi: 10.1016/j.clinbiomech.2006.06.004. Epub 2006 Aug 17.
- Jia X, Suo S, Meng F, Wang R. Effects of alignment on interface pressure for transtibial amputee during walking. Disabil Rehabil Assist Technol. 2008 Nov;3(6):339-43. doi: 10.1080/17483100802044634.
- Xiaohong J, Xiaobing L, Peng D, Ming Z. The Influence of Dynamic Trans-tibial Prosthetic Alignment on Standing Plantar Foot Pressure. Conf Proc IEEE Eng Med Biol Soc. 2005;2005:6916-8. doi: 10.1109/IEMBS.2005.1616096.
- Lee VS, Solomonidis SE, Spence WD. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study. Proc Inst Mech Eng H. 1997;211(2):167-80. doi: 10.1243/0954411971534287.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Očekávaný)
Primární dokončení
Dokončení studie (Očekávaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
Další identifikační čísla studie
- 09.2019.359
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .