Reverse Trendelenburg Position Versus Semi-recumbent Position in Obese Critically Ill Patients
Effect of Reverse Trendelenburg Position Versus Semi-recumbent Position on Ventilation and Oxygenation Parameters in Obese Critically Ill Patients: Randomized Controlled Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Alexandria, Egypt, 21548
- Alexandria University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- body mass index ≥ 30
- Mechanically ventilated
Exclusion Criteria:
- Trauma
- Shock
- Acute respiratory distress syndrome
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Reverse Trendelenburg position group
Obese critically ill patients who are positioned in reverse Trendelenburg position
|
The Reverse Trendelenburg position is a position in which patients' hip and knee are not flexed but the head and chest are elevated at 30° than the abdomen and legs.
|
|
Active Comparator: Semi-recumbent position group
Obese critically ill patients who are positioned in semi-recumbent position which is the routine ICU position
|
The semi-recumbent position is an upright positioning of the head and torso at an angle of 45° while legs are lying on the bed.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Respiratory dynamic compliance
Time Frame: 30 minute form positioning time
|
Respiratory dynamic compliance (Cdyn) in ml/cm H2O is the change in lung volume per unit change in pressure in the presence of flow.
It is calculated through the equation of tidal volume/ (peak inspiratory pressure - positive end expiatory pressure).
All the previous equation variables are assessed from the patient's mechanical ventilator data.
|
30 minute form positioning time
|
|
Respiratory minute volume
Time Frame: 30 minute form positioning time
|
Respiratory minute volume (VE) in mL/min is the total volume of air that is expired over one minute.
It is calculated directly by the mechanical ventilator and presented on patient's mechanical ventilator data.
|
30 minute form positioning time
|
|
Partial pressure carbon dioxide
Time Frame: 30 minute form positioning time
|
Partial pressure carbon dioxide (PaCO2) in mm Hg is assessed from arterial blood gases sample.
|
30 minute form positioning time
|
|
Partial pressure oxygen
Time Frame: 30 minute form positioning time
|
Partial pressure oxygen (PaO2) in mm Hg is assessed from arterial blood gases sample.
|
30 minute form positioning time
|
|
Hypoxemic index
Time Frame: 30 minute form positioning time
|
Hypoxemic index is the ratio of partial pressure oxygen to fraction inspiratory oxygen (PaO2/FiO2).
|
30 minute form positioning time
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 1212020
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.