VIenna Pilot Study for Automated Annular Suturing Technology (VIP-RAM)
VIenna Pilot Study for Automated Annular Suturing Technology to Assist in Aortic & Mitral Valve Replacement - A Single-center Clinical Safety & Feasibility Pilot Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Martin Andreas, Assoc. Prof. PD MD MBA, PhD,
- Phone Number: +43 1 40400 52620
- Email: martin.andreas@meduniwien.ac.at
Study Contact Backup
- Name: Paul Werner, MD
- Phone Number: - 47031 +43 1 40400
- Email: paul.werner@meduniwien.ac.at
Study Locations
-
-
-
Vienna, Austria, 1090
- Recruiting
- Medical University of Vienna
-
Contact:
- Martin Andreas, MD, PhD
- Phone Number: +4314040069660
- Email: martin.andreas@meduniwien.ac.at
-
Contact:
- Paul Werner, MD
- Phone Number: +43 (0)1 40400 - 47031
- Email: paul.werner@meduniwien.ac.at
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients with low to moderate operative risk (Defined by STS mortality risk below 8%)
- Patients above the age of 18 years
- Patients willing and able to sign the informed consent
Exclusion Criteria:
- Patients with active endocarditis
- Patients with previous cardiac surgery other than pacemaker implantation
- Emergency procedures
- Patient who did not sign the informed consent form and/ or refuse to participate
- Patients unable to read or understand the informed consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: surgical aortic valve replacement
n=20 patients with aortic valve pathology and indication for surgical aortic valve replacement
|
RAM® Automated Suturing Technology.
The RAM® DEVICE and SEW-EASY® DEVICE are automated suturing devices indicated for use in the approximation of soft tissue and prosthetic materials when used in conjunction with RAM® COR-SUTURE® QUICK LOAD® surgical suture.
Devices will be used for the approximation of respective replacement valves during surgical aortic or mitral valve replacement as described in the study protocol.
Cases may include use of the RAM® RING/RAM® RACK devices for suture management and the Aortic Root Retractor (ARR) with delivery device.
|
|
Other: surgical mitral valve replacement
n=10 patients with mitral valve pathology and indication for surgical mitral valve replacement
|
RAM® Automated Suturing Technology.
The RAM® DEVICE and SEW-EASY® DEVICE are automated suturing devices indicated for use in the approximation of soft tissue and prosthetic materials when used in conjunction with RAM® COR-SUTURE® QUICK LOAD® surgical suture.
Devices will be used for the approximation of respective replacement valves during surgical aortic or mitral valve replacement as described in the study protocol.
Cases may include use of the RAM® RING/RAM® RACK devices for suture management and the Aortic Root Retractor (ARR) with delivery device.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Freedom from mortality at 30 days post-OP assessed by clinical follow-up reports.
Time Frame: 30 days post surgical valve replacement
|
Follow-ups 30 days post-OP are performed and freedom from mortality evaluated.
|
30 days post surgical valve replacement
|
|
Implantation time assessed by surgical report.
Time Frame: procedural
|
Implantation time, the duration defined from start of the valve assessment until the completion of the prosthesis implantation (defined as fixation of the last suture) assessed by surgical report.
|
procedural
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Freedom from severe adverse events at 30 days post-OP assessed by clinical follow-up reports
Time Frame: 30 days post surgical valve replacement
|
Follow-ups 30 days post-OP are performed to and freedom from severe adverse events evaluated.
|
30 days post surgical valve replacement
|
|
Surgical times assessed by surgical report.
Time Frame: procedural
|
Surgical times, aortic cross-clamp time and cardiopulmonary-bypass time, assessed by surgical report.
|
procedural
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Martin Andreas, Assoc. Prof. PD MD MBA, PhD,, Medical University of Vienna
Publications and helpful links
General Publications
- Wong JK, Melvin AL, Siordia JA, Joshi DJ, Sauer JS, Knight PA. Novel Automated Suturing Technology for Minimally Invasive Aortic Valve Replacements. Ann Thorac Surg. 2018 Feb;105(2):645-649. doi: 10.1016/j.athoracsur.2017.07.054. Epub 2017 Nov 27.
- Johnson CA Jr, Melvin AL, Lebow BF, Yap A, Knight PA. Video assisted right mini-thoracotomy for aortic valve replacement. J Vis Surg. 2018 Feb 27;4:39. doi: 10.21037/jovs.2018.01.16. eCollection 2018.
- Robinson DA, Sagebin F, Yap AJ, Johnson CA Jr, Knight PA. Aortic valve replacement with annular enlargement via a right anterior minithoracotomy. Multimed Man Cardiothorac Surg. 2018 Jul 26;2018. doi: 10.1510/mmcts.2018.044.
- Nellis JR, Fitch ZW, Choi AY, Meza JM, Spector ZZ, Von Bergen NH, Torres JE, Klapper JA, Sauer JS, Turek JW. A Minimally Invasive Approach for Placing Sew-On Epicardial Leads in the Child. Innovations (Phila). 2018 Nov/Dec;13(6):455-457. doi: 10.1097/IMI.0000000000000568.
Study record dates
Study Major Dates
Study Start (Anticipated)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- EC 1660/2019
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.