Wireless Micropump in Dry Eye Patients
Clinical Efficacy of Wireless Micropump in Dry Eye Patients
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: yan wang, director
- Phone Number: +862227313336
- Email: wangyan7143@vip.sina.com
Study Locations
-
-
-
Tianjin, China
- Recruiting
- Tianjin Eye Hospital
-
Contact:
- Yan Wang, director
- Phone Number: +86-02227305083
- Email: wangyan7143@vip.sina.com
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- elimination of serious mental and psychological diseases;
- be accompanied by a parent or guardian who is able to give informed consent as demonstrated by signing a record of informed consent;
- be willing to comply with the clinical trial visit schedule as directed by the investigator;
- at baseline, be within the age range of 18 to 80 years old inclusive;
- BCVA≥1.0 of both eyes for each patient;
- dry eye test is BUT<5s and or Schimer test<5mm/5min;
- without other ophthalmic diseases;
Exclusion Criteria:
- At the same time, patients with other eye diseases (such as glaucoma, corneal opacity, uveitis, etc.) were diagnosed;
- serious mental and psychological diseases;
- history of refractive surgery;
- nystagmus or failure to cooperate;
- history of intraocular surgery;
- patients with systemic diseases (such as diabetes, hypertension, heart disease, etc.)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: sodium hyaluronate
Sodium hyaluronate has become a novel and effective eye drop for the treatment of the dry eye.
However, we design a special method of usage of sodium hyaluronate in dry eye patients.
|
We usage a special type of anterior eye drug delivery system to conduct the transmission of sodium hyaluronate in dry eye patients.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
tear film break-up time
Time Frame: change from baseline with OCCULUS at 6 months
|
change before and after sodium hyaluronate with OCCULUS
|
change from baseline with OCCULUS at 6 months
|
|
tear film thickness
Time Frame: change from baseline with OCCULUS at 6 months
|
change before and after sodium hyaluronate with OCCULUS
|
change from baseline with OCCULUS at 6 months
|
|
corneal epithelium defect percentage
Time Frame: change from baseline with OCCULUS at 6 months
|
change before and after sodium hyaluronate with OCCULUS
|
change from baseline with OCCULUS at 6 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Director: Yan Wang, director, Tianjin Eye Hospital
- Principal Investigator: Xuexin Duan, professor, Tianjin University
Publications and helpful links
General Publications
- Resto PJ, Berthier E, Beebe DJ, Williams JC. An inertia enhanced passive pumping mechanism for fluid flow in microfluidic devices. Lab Chip. 2012 Jun 21;12(12):2221-8. doi: 10.1039/c2lc20858j. Epub 2012 Mar 23.
- Kamal T, Watkins R, Cen Z, Rubinstein J, Kong G, Lee WM. Design and fabrication of a passive droplet dispenser for portable high resolution imaging system. Sci Rep. 2017 Jan 27;7:41482. doi: 10.1038/srep41482.
- Kwon JW, Kim JS, Choi SB, Lee JH, Wee WR. Experimental study of an automated system for the delivery of eyedrops using a microinfusion pump. Am J Ophthalmol. 2005 Mar;139(3):547-9. doi: 10.1016/j.ajo.2004.08.051.
- Huang PH, Nama N, Mao Z, Li P, Rufo J, Chen Y, Xie Y, Wei CH, Wang L, Huang TJ. A reliable and programmable acoustofluidic pump powered by oscillating sharp-edge structures. Lab Chip. 2014 Nov 21;14(22):4319-23. doi: 10.1039/c4lc00806e.
- Wu Z, Cai H, Ao Z, Nunez A, Liu H, Bondesson M, Guo S, Guo F. A Digital Acoustofluidic Pump Powered by Localized Fluid-Substrate Interactions. Anal Chem. 2019 Jun 4;91(11):7097-7103. doi: 10.1021/acs.analchem.9b00069. Epub 2019 May 14.
Study record dates
Study Major Dates
Study Start (Anticipated)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 202076
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.