Total-body 13N-NH3 PET/CT to Study the Blood Perfusion in Severe AS Patients Pre- and Post-TAVR in Whole Body
The Application of Total-body 13N-NH3 PET/CT to Study the Blood Perfusion System in Severe AS Patients Before and After TAVR Surgery in the Whole Body
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Xiaofeng Yu
- Phone Number: 86-021-58752345
- Email: minkeyperfect@126.com
Study Contact Backup
- Name: Yumei Chen, Ph.D; M.D.
- Phone Number: 86-021-58752345
- Email: cymrenji@126.com
Study Locations
-
-
Shanghai Municipality
-
Shanghai, Shanghai Municipality, China, 200127
- Shanghai Jiaotong University School of Medicine, Renji Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Nine healthy volunteers with normal EF values
- Patients with decreased cardiac function, while their heart function grading above II(New York Heart Association,NYHA)
- Aged 60~90 years old
- Written informed consents will be offered and signed by all participants
Exclusion Criteria:
- History of vascular-related diseases in other organs
- Severe liver and kidney dysfunctions
- Patients who are pregnant or breast feeding
- People under the age of 60 years old
- Heart function grading below II(NYHA)
- inability to lie or to maintain posture in the scanner for one hour
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Healthy controls
All healthy subjects will undergo the following intervention: 13N-NH3 PET/CT scan on the total-body uEXPLORER scanner.
|
This prospective study will enroll twenty-five patients, including nine healthy volunteers, sixteen patients with decreased cardiac function .
All of them will have a whole-body PET/CT(uEXPLORER , United Imaging Healthcare, China) in our department, Renji Hospital.
|
|
Patients with cardiac disfunction
All patients will undergo the following intervention: 13N-NH3 PET/CT scan on the total-body uEXPLORER scanner.
|
This prospective study will enroll twenty-five patients, including nine healthy volunteers, sixteen patients with decreased cardiac function .
All of them will have a whole-body PET/CT(uEXPLORER , United Imaging Healthcare, China) in our department, Renji Hospital.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of Multi-Organ Blood Perfusion by Total Body Dynamic uEXPLORER PET/CT Scan
Time Frame: 4 years
|
The total-body 13N-NH3 PET/CT will be adopted to evaluate the blood flow differences in whole body between healthy controls and patients with decreased cardiac function.
|
4 years
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Yumei Chen, Ph.D; M.D., Renji Hospital
Publications and helpful links
General Publications
- Benz DC, Ferro P, Safa N, Messerli M, von Felten E, Huang W, Patriki D, Giannopoulos AA, Fuchs TA, Grani C, Gebhard C, Pazhenkottil AP, Kaufmann PA, Buechel RR. Role of quantitative myocardial blood flow and 13N-ammonia washout for viability assessment in ischemic cardiomyopathy. J Nucl Cardiol. 2021 Feb;28(1):263-273. doi: 10.1007/s12350-019-01684-1. Epub 2019 Mar 20.
- Lang JK, Canty JM Jr. The complexity of using resting myocardial perfusion to assess myocardial viability and predict functional recovery. J Nucl Cardiol. 2021 Feb;28(1):274-277. doi: 10.1007/s12350-019-01742-8. Epub 2019 May 13. No abstract available.
- Kang KW, Kim JS, Cho SG, Kim J, Song HC. Acquisition of dynamic N-13 ammonia PET for myocardial blood flow quantification. J Nucl Cardiol. 2020 Aug;27(4):1288-1292. doi: 10.1007/s12350-020-02062-y. Epub 2020 Feb 19. No abstract available.
- Giubbini R, Peli A, Milan E, Sciagra R, Camoni L, Albano D, Bertoli M, Bonacina M, Motta F, Statuto M, Rodella CA, De Agostini A, Calabretta R, Bertagna F; Italian Nuclear Cardiology Group (GICN). Comparison between the summed difference score and myocardial blood flow measured by 13N-ammonia. J Nucl Cardiol. 2018 Oct;25(5):1621-1628. doi: 10.1007/s12350-017-0789-z. Epub 2017 Feb 3.
- Sciagra R, Lubberink M, Hyafil F, Saraste A, Slart RHJA, Agostini D, Nappi C, Georgoulias P, Bucerius J, Rischpler C, Verberne HJ; Cardiovascular Committee of the European Association of Nuclear Medicine (EANM). EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging. Eur J Nucl Med Mol Imaging. 2021 Apr;48(4):1040-1069. doi: 10.1007/s00259-020-05046-9. Epub 2020 Nov 2.
- Lammertsma AA. Forward to the Past: The Case for Quantitative PET Imaging. J Nucl Med. 2017 Jul;58(7):1019-1024. doi: 10.2967/jnumed.116.188029. Epub 2017 May 18.
- Akamatsu G, Uba K, Taniguchi T, Mitsumoto K, Narisue A, Tsutsui Y, Sasaki M. Impact of Time-of-Flight PET/CT with a Large Axial Field of View for Reducing Whole-Body Acquisition Time. J Nucl Med Technol. 2014 Jun;42(2):101-4. doi: 10.2967/jnmt.114.140665. Epub 2014 May 5.
- Zhang X, Cherry SR, Xie Z, Shi H, Badawi RD, Qi J. Subsecond total-body imaging using ultrasensitive positron emission tomography. Proc Natl Acad Sci U S A. 2020 Feb 4;117(5):2265-2267. doi: 10.1073/pnas.1917379117. Epub 2020 Jan 21.
- Zhang X, Xie Z, Berg E, Judenhofer MS, Liu W, Xu T, Ding Y, Lv Y, Dong Y, Deng Z, Tang S, Shi H, Hu P, Chen S, Bao J, Li H, Zhou J, Wang G, Cherry SR, Badawi RD, Qi J. Total-Body Dynamic Reconstruction and Parametric Imaging on the uEXPLORER. J Nucl Med. 2020 Feb;61(2):285-291. doi: 10.2967/jnumed.119.230565. Epub 2019 Jul 13.
- Cherry SR, Jones T, Karp JS, Qi J, Moses WW, Badawi RD. Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care. J Nucl Med. 2018 Jan;59(1):3-12. doi: 10.2967/jnumed.116.184028. Epub 2017 Sep 21.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- KY2021-086
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.