Assessment of Vertical Root Fracture Resistance of Endodontically Treated Teeth Instrumented by Single Endodontic Files
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Sindh
-
Karachi, Sindh, Pakistan, 75300
- Dow University of Health Sciences
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
Extracted Human mandibular premolar canals that fulfill the following criteria were used.
- permanent teeth
- intact and fully formed apices
- straight and single rooted canal
- roots having similar diameter mesiodistally(2-4mm) and buccolingually(4-6mm)
Exclusion Criteria:
Roots having following features were excluded;
- root caries
- roots with multiple canals
- previous root canal treatment done
- signs of calcification, internal and external root resorption
- cracks
- fracture lines
- C-shaped canals
- Vertical Root Fracture
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: Randomized
- Interventional Model: Factorial Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Hyflex EDm
The canals were prepared and shaped with one file (25/~) and finished with 40/.04 using crown down technique.
Torque controlled endodontic motor was used with a rotational speed of 500 rpm and torque of 2.5Ncm (25 Nm).
|
Root canal shaping procedures were performed.
Irrigation was done after each three pecks of endodontic file.
After instrumentation (Groups 1-3), the canals were dried with sterile paper points.
The dentinal walls were then coated with Sealapex.
For vertical root fracture resistance testing, sample preparation was done in acrylic blocks.
Then roots were coated with polyvinylsiloxane impression material.
After that roots were inserted again into acrylic resin blocks.
The acrylic blocks with the vertically aligned roots were mounted in the Instron testing machine.
0.5 mm diameter round tip stainless-steel rod was fixed to the universal testing machine.
The universal testing machine was adjusted and vertical compressive force was applied at a crosshead speed of 1mm/min.
The Instron tester applied a slowly increasing force, until the root fractured.
The maximum amount of force necessary to fracture every sample was recorded in Newton (N).
|
|
Experimental: F6 SkyTaper
The canals were prepared and shaped with one file (25/~) and finished with 40/.04 using crown down technique.
Torque controlled endodontic motor was used with a rotational speed of 500 rpm and torque of 2.5Ncm (25 Nm).
|
Root canal shaping procedures were performed.
Irrigation was done after each three pecks of endodontic file.
After instrumentation (Groups 1-3), the canals were dried with sterile paper points.
The dentinal walls were then coated with Sealapex.
For vertical root fracture resistance testing, sample preparation was done in acrylic blocks.
Then roots were coated with polyvinylsiloxane impression material.
After that roots were inserted again into acrylic resin blocks.
The acrylic blocks with the vertically aligned roots were mounted in the Instron testing machine.
0.5 mm diameter round tip stainless-steel rod was fixed to the universal testing machine.
The universal testing machine was adjusted and vertical compressive force was applied at a crosshead speed of 1mm/min.
The Instron tester applied a slowly increasing force, until the root fractured.
The maximum amount of force necessary to fracture every sample was recorded in Newton (N).
|
|
Experimental: One Shape
Canals were prepared and shaped with single rotational file system One Shape with the sequence of Endoflare (12, 0.12), One G (18, 0.03) and One Shape (12.06) connected to endodontic motor with rotational speed of 400rpm and 4 Ncm torque as recommended by manufacturer.
|
Root canal shaping procedures were performed.
Irrigation was done after each three pecks of endodontic file.
After instrumentation (Groups 1-3), the canals were dried with sterile paper points.
The dentinal walls were then coated with Sealapex.
For vertical root fracture resistance testing, sample preparation was done in acrylic blocks.
Then roots were coated with polyvinylsiloxane impression material.
After that roots were inserted again into acrylic resin blocks.
The acrylic blocks with the vertically aligned roots were mounted in the Instron testing machine.
0.5 mm diameter round tip stainless-steel rod was fixed to the universal testing machine.
The universal testing machine was adjusted and vertical compressive force was applied at a crosshead speed of 1mm/min.
The Instron tester applied a slowly increasing force, until the root fractured.
The maximum amount of force necessary to fracture every sample was recorded in Newton (N).
|
|
No Intervention: Control
In the control group, no endodontic instrumentation and shaping was done in the canals.
Only the necrotic pulp tissue was extirpated from the canals with the help of barbed broaches and then the specimens were analyzed for fracture testing.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Vertical Root Fracture Resistance
Time Frame: 5 minutes
|
The acrylic blocks with the vertically aligned roots were mounted in the Instron testing machine one at a time.
0.5 mm diameter round tip stainless-steel rod was fixed to the upper stage of the universal testing machine (Instron, Canton, MA, USA).
The rod was centered over the canal orifice of each root.
The universal testing machine (Instron) was adjusted and vertical compressive force was applied at a crosshead speed of 1mm/min.
The Instron tester applied a slowly increasing force, at a rate of 1.0 mm per min, until the root fractured.
This point was verified by the computer monitoring the Instron testing machine; at the same time the crack was heard, the monitor showed a sharp drop in force.
The test was terminated at this point and the force applied was recorded.
The maximum amount of force necessary to fracture every sample was recorded in Newton (N).
|
5 minutes
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Crack pattern
Time Frame: 2 minutes
|
crack pattern is complete/incomplete
|
2 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Farah Naz, BDS,FCPS, Dow University of Health Sciences
Publications and helpful links
General Publications
- Pawar AM, Pawar MG, Thakur B, Banga KS, Luke AM. Resistance to fracture of teeth instrumented using novel EndoStar E5 rotary versus ProTaper NEXT and WaveOne file systems. J Conserv Dent. 2018 Jan-Feb;21(1):52-56. doi: 10.4103/JCD.JCD_216_16.
- Pawar AM, Barfiwala D, Pawar M, Metzger Z, Kfir A, Jain N. Assessment of the fracture resistance of teeth instrumented using 2 rotary and 2 reciprocating files versus the Self-Adjusting File (SAF): An ex vivo comparative study on mandibular premolars. J Conserv Dent. 2016 Mar-Apr;19(2):138-42. doi: 10.4103/0972-0707.178692.
- Capar ID, Altunsoy M, Arslan H, Ertas H, Aydinbelge HA. Fracture strength of roots instrumented with self-adjusting file and the ProTaper rotary systems. J Endod. 2014 Apr;40(4):551-4. doi: 10.1016/j.joen.2013.08.030. Epub 2013 Oct 15.
- Tavanafar S, Karimpour A, Karimpour H, Mohammed Saleh A, Hamed Saeed M. Effect of Different Instrumentation Techniques on Vertical Root Fracture Resistance of Endodontically Treated Teeth. J Dent (Shiraz). 2015 Mar;16(1 Suppl):50-5.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IRB-1658/DUHS/Approval/2020/
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.