Tolerance to Residual Astigmatism in Eyes With Vivity®
Tolerance to Residual Astigmatism and Defocus in Eyes With a Non-diffractive Extended Depth of Focus (EDoF) Intraocular Lens
Low amounts of postoperative residual astigmatism may worsen the visual performance of patients implanted with presbyopia- correcting intraocular lenses (IOLs). Although extended depth of focus (EDoF) IOLS have introduced optical improvements, it is important to determine the tolerance of these IOLs to postoperative astigmatism. This is important for an appropriate surgical planning.
Therefore, the aim of this study is to simulate and assess the impact of mild amounts of residual mixed astigmatisms with the axis oriented in different positions (vertical, oblique and horizontal) in eyes implanted with the Vivity® IOL.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Objectives:
- Primary objective: To describe the tolerance of simulated astigmatism on patients implanted with Vivity at far distance.
- Secondary objective: To describe the tolerance of simulated astigmatism on patients implanted with Vivity at intermediate distance.
Study Design: Prospective, single arm, descriptive, 3-month follow up.
Patient population: 30 consecutive eyes of 30 patients implanted with Vivity bilaterally with no postoperative complications. The calculation of the required sample size was based on monocular corrected distande visual acuity. A difference of 0.2 logMAR units was assumed to be clinically significant anda standard deviation of 0.05 was anticipated(data obtained from a comparative study between a bifocal and a trifocal IOL: Jonker SM, et al. Journal of Cataract Refract Surg. 2015; 41: 1631-40). Based on these assumptions, with an α of 0.05 and power of 0.8, it was calculated that 25 eyes were required in each group. Due to potential dropouts, a larger sample size has been selected.
Clinical Protocol: All patients fullfilling study criteria will be considered for inclusion three months after surgery. After patient consent, uncorrected distance visual acuity will be measured with an ETDRS chart, followed by subjective refraction (best distance correction). In all cases, mixed astigmatism will be induced with trial lens over the best distance corrected situation (considered the reference situation).
Once the best distance correction is determined, the different visual acuity evaluation procedures for this study will be performed with a Freiburg Acuity Test software package. The software will be run on a separate laptop screen calibrated to be presented at 4 meters. In this procedure, a black Landolt C is presented to the subjects and, among 8 different possibilities, they indicate the orientation of the optotype on a numeric keypad. This test minimizes the observer's bias because the presented optotype depends on the patient´s previous responses. That is, when the observer responds to a certain optotype, the software automatically modifies the size of the next optotype according to parameter estimation by a sequential test method. (7,8) Finally, all serious adverse events will be reported.
Statistical Analysis: Visual acuity values will be expressed as mean and standard deviation. Normal distribution of variables will be assessed using the Kolmogorov- Smirnov test. Pre- and post-operative data of each parameter will be compared by means of the Student's t-test. A repeated measure analysis of variance (ANOVA) will be used to gauge any statistically significant difference of the data within the different simulated situations. Differences are considered to be statistically significant for P value <0.05 (i.e., at the 5% level).
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Madrid, Spain, 28010
- Clinica Rementeria
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients >40 years old that undergo routine cataract surgery
- Bilateral implantation of Vivity ® IOL
Exclusion Criteria:
- Corneal astigmatism ≥1.0 diopters (D )
- Amblyopia
- Previous ocular surgery
- Presence of ocular pathologies
- Abnormal iris
- Patients with intra- or postoperative complications
- Postoperative best distance corrected visual acuity (BDCVA) < 20/20
- Postoperative refractive astigmatism > 0.50D
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Vivity patients
The study will include patients >40 years old that undergo routine cataract surgery and implantation of Vivity ®. Exclusion criteria include corneal astigmatism ≥1.0 diopters (D ), amblyopia, previous ocular surgery and presence of ocular pathologies and abnormal iris. Patients with intra- or postoperative complications, with a postoperative best distance corrected visual acuity (BDCVA) < 20/20 and with postoperative refractive astigmatism > 0.50D will be also excluded . Inclusion and exclusion criteria will be assessed by an ophthalmologic examination including refraction, screening for ocular conditions and/or systemic diseases, slit-lamp biomicroscopy and fundus examination. |
Cataract surgery with Vivity intraocular lens implantation
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Distance Against the Rule Astimatism
Time Frame: Three months after surgery
|
Change from baseline condition in the monocular best corrected distance visual acuity, inducing astigmatism of +0.25-0.50x0*,
taking as a reference the subjects' axis
|
Three months after surgery
|
|
Distance Oblique Astigmatism
Time Frame: Three months after surgery
|
Change from baseline condition in the monocular best corrected distance visual acuity, inducing astigmatism of +0.25-0.50x45*,
taking as a reference the subjects' axis
|
Three months after surgery
|
|
Distance With the Rule Astigmatism
Time Frame: Three months after surgery
|
Change from baseline condition in the monocular best corrected distance visual acuity, inducing astigmatism of +0.25-0.50x90*,
taking as a reference the subjects' axis
|
Three months after surgery
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Intermediate against the rule astigmatism
Time Frame: Three months after surgery
|
Change from baseline condition in the simulated (with -1.50 D) Monocular intermediate visual acuity inducing astigmatism of +0.25-0.50x0*
|
Three months after surgery
|
|
Intermediate oblique astigmatism
Time Frame: Three months after surgery
|
Change from baseline condition in the simulated (with -1.50 D) Monocular intermediate visual acuity inducing astigmatism of +0.25-0.50x45*
|
Three months after surgery
|
|
Intermediate with the rule astigmatism
Time Frame: Three months after surgery
|
Change from baseline condition in the simulated (with -1.50 D) Monocular intermediate visual acuity inducing astigmatism of +0.25-0.50x90*
|
Three months after surgery
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Laureano Rementeria-Capelo, MD, Clinica Rementeria
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 21/365-O_P_Viv
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.