Visual Acuity After Using A New Monofocal Intraocular Lens Compared To Standard Monofocal Lens
Distance And Intermediate Visual Acuity After Phacoemulsification Using A New Generation Monofocal Intraocular Lens Compared To Standard Monofocal Intraocular Lens
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Purpose To determine the Uncorrected and best-corrected distance, and intermediate visual acuity in a new innovative monofocal intraocular lens compared with standard monofocal lens.
Methods This is a prospective comparative interventional clinical study, that took place from January 2021 to November 2021. 40 eyes of Twenty patients (20) were enrolled in this study, patients who are candidates for cataract extraction by phacoemulsification were included in this study and underwent thorough preoperative examination and post-operative evaluation at 3 months after the 2nd eye operation, of distance, intermediate, near add, contrast sensitivity and incidence of photic phenomena using a printed questionnaire for evaluating this incidence and binocular defocus curves were analyzed.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Giza, Egypt, 11555
- Kasraliany Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients aged 50-75 years old undergoing cataract surgery.
- Preoperative corneal astigmatism equal to or less than - 1.00 D.
- Availability, willingness and sufficient cognitive awareness to comply with examination procedures
Exclusion Criteria:
- Visual potential of less than 0.63 due to ocular pathologies.
- Corneal astigmatism over -1.00 D cylinder.
- Pupil abnormalities (non-reactive, tonic pupils, abnormally shaped pupils, or pupils that do not dilate at least 3.5 mm under mesopic/scotopic conditions).
- Capsule or zonular abnormalities that would affect postoperative centration or tilt of the lens and pseudoexfoliation syndrome.
- Macular degeneration, cystoid macular edema,Diabetic retinopathy, history of uveitis, optic nerve diseases, glaucoma and amblyopia.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: HEALTH_SERVICES_RESEARCH
- Allocation: NON_RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
ACTIVE_COMPARATOR: Eyhance intraocular lens
10 patients bilaterally implanted with Eyhance intraocular lens
|
cataract extraction followed by bilateral implantation of Eyhance intraocular lens in 10 patients and bilateral implantation of Tecnis 1 piece IOL in 10 patients
Other Names:
implantation of monofocal intraocular lens in the capsular bag at the end of phacoemulsification surgery
|
|
ACTIVE_COMPARATOR: Tecnis 1 piece intraocular lens
10 patients bilaterally implanted with Tecnis 1 piece intraocular lens
|
cataract extraction followed by bilateral implantation of Eyhance intraocular lens in 10 patients and bilateral implantation of Tecnis 1 piece IOL in 10 patients
Other Names:
implantation of monofocal intraocular lens in the capsular bag at the end of phacoemulsification surgery
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Uncorrected and best-corrected distance, and intermediate visual acuity.
Time Frame: 3 months post operative
|
Distance visual acuities were examined by ETDRS chart and intermediate and near visual acuity by Jaeger chart at 66 cm and 33 cm respectively.Measured values of the visual acuity were expressed in decimal values and converted to logMAR values.
|
3 months post operative
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Contrast sensitivity
Time Frame: 3 months post operative
|
Contrast sensitivity was measured using Pelli Robson illuminated chart at 1m
|
3 months post operative
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: yehia Salaheldin, PhD, Cairo University
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- MS-239-2021
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.