RSA Masterloc Study Australia
Prospective, Multicentric Study to Assess Stability of a Tapered Porous Coated Stem and a Cementless Hemispherical Acetabular Component
This is a prospective, multicentric study that aim to assess stability of a tapered porous coated stem and a cementless hemispherical acetabular component.
Main Translation and rotation around the x., y-, and z-axis of the femoral and cup component by radiostereometric analysis (RSA) at immediate post op (within 5 days and before weight bearing), 6 months, 1year and 2 years
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Aim of this study is to assess stem and cup migration over the time in patient subjected to a total hip arthroplasty. Medical Device Research Australia will perform image analysis services and reporting for model based radiostereometric analysis (RSA) of cementless fixation of the femoral and acetabular cup components. Migration of the components will be measured with model-based RSA (MBRSA) at immediate post op (within 5 days and before weight bearing), 6 months, 1year and 2 years A subgroup of 26 patients will be invited to be evaluated also by additional RSA analysis: the first 13 patients for each investigator who will accept.
The results of this work will establish the mechanical stability of Masterloc femoral component (Medacta International SA) and MPACT acetabular component (Medacta International SA), provide a general estimate of survivorship, and establish clinical safety and efficacy as measured by RSA and clinical outcomes.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Sydney, Australia
- Southerland Public Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Primary osteoarthritis of the hip necessitating primary hip replacement,
- Suitability for straight cementless stem,
- Adult male and female under 70years old,
- Ability to give informed consent,
- Patients who understand the conditions of the study and are willing to participate for the length of the prescribed follow-up.
Exclusion Criteria:
- Post-traumatic deformity in the affected hip,
- Patient suffering by rheumatoid arthritis,
- Patient suffering by congenital or developmental deformity,
- Severe osteoporosis,
- Earlier surgery in the hip to be operated on,
- Perioperative fracture,
- Personal disorders (dementia, alcohol or drug abuse etc) suspected of making completion of the trial uncertain,
- Patients with a history of active infection
- Pregnant women or those seeking to become pregnant
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
RSA imaging
Time Frame: 2 years
|
All RSA analysis will be performed Computer Aided Design (CAD) based Roentgen Stereophotogrammetry Analysis (RSA). The micro-motion results will be calculated and reported as translations and rotations along and about the three anatomic axes. The subsidence of the hip stem is included in the results. The motion of the femoral stem and acetabular cup will be described in relation to the marker beads placed in the proximal femur and acetabular bone during surgery respectively. The first CAD based RSA examination (within 5 days and prior to weight bearing) serves as the reference baseline. All subsequent evaluations of micromotion are related to the relative position of the implanted medical device with respect to the bone (bone markers) at the time of the evaluation |
2 years
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Michael Dixon, Medicine, Southerland Public Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- P01.018.01
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Radiostereometric Analysis
-
NCT01754155UnknownRadiostereometric Analysis | Vitamin E Liner | Zimmer® Continuum® Acetabular Cup
-
NCT05877261CompletedKnee Osteoarthritis | Knee Arthroplasty, Total | Radiostereometric Analysis
-
NCT00634465WithdrawnAssess Motion in Flexion/Extension and Lateral Bending of the Lumbar Vertebrae in Vivo Following Motion Sparing Surgery Using Radiostereometric Analysis (RSA.)
-
NCT05151315Active, not recruitingKnee Osteoarthritis | Total Knee Arthroplasty | Radiostereometric Analysis
-
NCT06992518CompletedGait Analysis | 3D Gait Analysis
-
NCT06954675Recruiting
-
NCT07445464Not yet recruitingPharmacokinetic Analysis