Electrosurgical Modes for Endoscopic Submucosal Dissection in Peroral Endoscopic Esophageal Myotomy
Electrosurgical Modes for Endoscopic Submucosal Dissection in Peroral Endoscopic Esophageal Myotomy: a Randomized Controlled Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Phase 3
Contacts and Locations
Study Contact
Study Contact
- Name: Hany Shehab, MD, FRCP
- Phone Number: +201111111071
- Email: h.shehab@kasralainy.edu.eg
Study Locations
-
-
-
Cairo, Egypt, 11562
- Recruiting
- Cairo University
-
Contact:
- Hany M Shehab, MD
- Phone Number: 01111111071
- Email: H.shehab@kasralainy.edu.eg
-
Principal Investigator:
- Hany M Shehab, FRCP
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients undergoing POEM procedure for any esophageal motility disorder
- Esophageal motility disorder confirmed by high-resolution manometry and gastroscopy
Exclusion Criteria:
- Esophageal varices
- Esophageal neoplasms
- Non-correctable coagulopathy
- Failure to provide an informed consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Spray coag mode
After initial mucosal incision, Endoscopic submucosal dissection will be performed using Spray coag mode using ERBE VIO 3 generator (effect 3-3.5)
|
After initial mucosal incision, submucosal dissection will be performed down to 2cm below the cardia using Spray coag mode using ERBE VIO3 generator and a Hybrid knife (T-type) aided by ERBEJET for submucosal injection
Other Names:
|
|
Active Comparator: Precisect mode
After initial mucosal incision, Endoscopic submucosal dissection will be performed using Precisect mode using ERBE VIO 3 generator (effect 4.5-5)
|
After initial mucosal incision, submucosal dissection will be performed down to 2cm below the cardia using Precisect mode using ERBE VIO3 generator and a Hybrid knife (T-type) aided by ERBEJET for submucosal injection
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Speed of endoscopic submucosal dissection
Time Frame: during the procedure
|
Speed of dissection (cm/minute)
|
during the procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Intraprocedural Bleeding
Time Frame: during the procedure
|
Bleeding necessitating change in electrosurgical mode
|
during the procedure
|
|
Significant Intraprocedural bleeding
Time Frame: during the procedure
|
Bleeding necessitating change of instrument to coagulating forceps
|
during the procedure
|
|
Other Adverse events
Time Frame: during the procedure
|
Including mucosal injury, postoperative pain, postoperative bleeding and other complications
|
during the procedure
|
|
Total procedure duration
Time Frame: during the procedure
|
Total procedure duration
|
during the procedure
|
|
Endoscopic submucosal tunneling duration
Time Frame: during the procedure
|
Endoscopic submucosal tunneling duration
|
during the procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: hany shehab, Cairo University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- ESRCT
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.