Fluid Responsiveness Evaluation by a Non-invasive Method in Children, Extended to PREterm Infants - FRENCH-PREMA (FRENCH-PREMA)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Fluid expansion is the cornerstone of acute circulatory failure treatment in children and preterm infants with acute circulatory failure. Although this therapy drastically reduced mortality, several studies in recent years have highlighted the adverse effects of excessive fluid expansion especially for preterm infants such as PDA, chronic lung disease and mortality. Currently, the search for indicators to predict fluid responsiveness is a major issue in neonatal intensive care. These indicators are based on Franck-Starling's law: if small changes in preload lead to an increase in cardiac output, then fluid responsiveness can be expected. However, in children, the only validated indicator (respiratory variability of peak aortic velocity) can only be used in the absence of any spontaneous respiratory movement, a rare situation in practice. Recently, two pediatric studies investigated a simple clinical test: hepatic or abdominal compression. This clinical maneuver, by increasing venous return via mobilization of the hepato-splanchnic reserve, induces a transient and reversible preload increase. The evaluation of the hemodynamic effects of this "endogenous fluid expansion" allowed, according to the authors, to accurately predict fluid responsiveness. However, several factors reduce the applicability of these results: the small number of studies on this subject, the smaller volume of fluid used than in clinical practice, and the population studied, composed almost exclusively of children in postoperative of cardiac surgery.
Thus, there is a need of reliable preloads markers to guide intravenous volume rescusitation in neonates.
In this study, the investigators will evaluate the diagnostic accuracy of abdominal compression for the diagnosis of fluid responsiveness in preterm infants (<37WA) with acute circulatory failure, hospitalized in neonatal intensive care unit for a medical or a non-cardiac surgical condition, for whom a fluid expansion was prescribed by the physician in charge. The index test will be the stroke volume variation following a standardized abdominal compression (before fluid expansion). The gold standard test will be the variation of cardiac output between baseline and after fluid expansion, a variation > 15% defining fluid responsiveness.
In this non interventional study of diagnostic accuracy, patients will undergo an extra echocardiographic assessment, but no supplemental blood test or invasive parameters will be collected. Simple clinical parameters will be collected within 4 hours after the fluid expansion.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Sophie CRAMAREGEAS, MD
- Phone Number: 0557821269
- Email: sophie.cramaregeas@chu-bordeaux.fr
Study Contact Backup
- Name: Géraldine ROBERT
- Phone Number: 055821500
- Email: geraldine.robert@chu-bordeaux.fr
Study Locations
-
-
-
Bordeaux, France, 33076
- Recruiting
- Bordeaux Hospital University
-
Contact:
- Sophie CRAMAREGEAS, MD
- Phone Number: 0557821269
-
Contact:
- sophie.cramaregeas@chu-bordeaux.fr
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Premature newborn under 37 weeks of amenorrhea hospitalized in neonatal intensive care
- Prescription of a 10 to 20ml/kg fluid expansion (crystalloid, blood products or albumin) by the physician in charge, whose goal would be to increase cardiac output (based on clinical, biological and/or echographic criteria).
Exclusion Criteria:
- Acute cardiogenic pulmonary edema
- Hemodynamic instability making the delay necessary for abdominal compression and ultrasonography dangerous for the patient
- Non corrected congenital cardiopathy, or inferior to 15 days postoperative. Intra-abdominal hypertension or painful abdominal palpation
- Abdominal surgery in the last 15 days
- Supine position contraindicated or deleterious
- No investigator available to assess ultrasonographic measures
- Impairment of echocardiographic acoustic window or restless patient making ultrasonography impossible
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
study of diagnostic accuracy
Patients included in this study would have received fluid expansion in all cases, as the prescription of 10 to 20ml/kg fluid expansion by the physician in charge is the main inclusion criterion.
|
Study of diagnostic accuracy (non-interventional, prospective, monocentric). Fluid expansion will be delayed for a few minutes while our index test is performed. After fluid expansion, patient will undergo an echocardiographic assessment of response to fluid expansion (gold-standard test). This will allow to test the diagnostic performance of the index test for the "prediction" of fluid responsiveness. The index test is the ΔSVi-AC: indexed percentage of stroke volume variation between baseline and during a standardized abdominal compression. Stroke volume will be assessed by transthoracic echocardiography. Patient will undergo 3 echocardiographic assessment: At baseline (stroke volume, cardiac output, left ventricular ejection fraction), During a standardized abdominal compression (stroke volume),After the 10 to 20ml/kg fluid expansion prescribed by the physician in charge (cardiac output). |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value) of the index test (ΔSVi-AC) for the diagnosis of fluid responsiveness,
Time Frame: after abdominal compression, 30 minutes to 4 hours after baseline
|
Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value) of the index test (ΔSVi-AC) for the diagnosis of fluid responsiveness, defined by an increase of cardiac output > 15% after fluid expansion (ΔCO-FE > 15%, gold-standard test) Index test (ΔSVi-AC) will be calculated as the difference between SV after abdominal compression and SV at baseline, divided by SV at baseline (%). SV will be measured by echocardiographic assessment. Gold-standard test (ΔCO-FE) will be calculated as the difference between CO after fluid expansion and CO at baseline, divided by CO at baseline (%). CO will be measured by echocardiographic assessment. value) of the index test (ΔSVi-AC) for the diagnosis of fluid responsiveness, defined by an increase of cardiac output > 15% after fluid expansion (ΔCO-FE > 15%, gold-standard test) |
after abdominal compression, 30 minutes to 4 hours after baseline
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diagnostic accuracy of the SAV mean and the ΔPeak for the diagnosis of fluid responsiveness
Time Frame: after abdominal compression, 30 minutes to 4 hours after baseline
|
Diagnostic accuracy of the SAV mean and the ΔPeak for the diagnosis of fluid responsiveness, defined by an increase of cardiac output > 15% after fluid expansion (ΔCO-FE > 15%, gold-standard test) in preterm infants. Comparison of the diagnostic accuracy of these tests. |
after abdominal compression, 30 minutes to 4 hours after baseline
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Sophie CRAMAREGEAS, Bordeaux Hospital University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CHUBX 2023/32
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.