Fluid Responsiveness Evaluation by a Non-invasive Method in Children, Extended to PREterm Infants - FRENCH-PREMA (FRENCH-PREMA)

February 27, 2024 updated by: University Hospital, Bordeaux
In this study, the investigators aim to validate a non-invasive marker of fluid-responsiveness in preterm infants (term below 37 gestational week) with acute circulatory failure based on standardized abdominal compression. This would allow physicians to identify which patient could benefit from a fluid expansion, thus avoiding a potentially useless or even dangerous fluid expansion, leading to fluid overload. To this end, the investigators will evaluate the diagnostic accuracy (sensitivity and specificity) of stroke volume variation induced by standardized abdominal compression for the diagnosis of fluid responsiveness (based on the gold-standard test: significant increase in cardiac index after fluid expansion).

Study Overview

Detailed Description

Fluid expansion is the cornerstone of acute circulatory failure treatment in children and preterm infants with acute circulatory failure. Although this therapy drastically reduced mortality, several studies in recent years have highlighted the adverse effects of excessive fluid expansion especially for preterm infants such as PDA, chronic lung disease and mortality. Currently, the search for indicators to predict fluid responsiveness is a major issue in neonatal intensive care. These indicators are based on Franck-Starling's law: if small changes in preload lead to an increase in cardiac output, then fluid responsiveness can be expected. However, in children, the only validated indicator (respiratory variability of peak aortic velocity) can only be used in the absence of any spontaneous respiratory movement, a rare situation in practice. Recently, two pediatric studies investigated a simple clinical test: hepatic or abdominal compression. This clinical maneuver, by increasing venous return via mobilization of the hepato-splanchnic reserve, induces a transient and reversible preload increase. The evaluation of the hemodynamic effects of this "endogenous fluid expansion" allowed, according to the authors, to accurately predict fluid responsiveness. However, several factors reduce the applicability of these results: the small number of studies on this subject, the smaller volume of fluid used than in clinical practice, and the population studied, composed almost exclusively of children in postoperative of cardiac surgery.

Thus, there is a need of reliable preloads markers to guide intravenous volume rescusitation in neonates.

In this study, the investigators will evaluate the diagnostic accuracy of abdominal compression for the diagnosis of fluid responsiveness in preterm infants (<37WA) with acute circulatory failure, hospitalized in neonatal intensive care unit for a medical or a non-cardiac surgical condition, for whom a fluid expansion was prescribed by the physician in charge. The index test will be the stroke volume variation following a standardized abdominal compression (before fluid expansion). The gold standard test will be the variation of cardiac output between baseline and after fluid expansion, a variation > 15% defining fluid responsiveness.

In this non interventional study of diagnostic accuracy, patients will undergo an extra echocardiographic assessment, but no supplemental blood test or invasive parameters will be collected. Simple clinical parameters will be collected within 4 hours after the fluid expansion.

Study Type

Observational

Enrollment (Estimated)

20

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Study Locations

      • Bordeaux, France, 33076
        • Recruiting
        • Bordeaux Hospital University
        • Contact:
          • Sophie CRAMAREGEAS, MD
          • Phone Number: 0557821269
        • Contact:
          • sophie.cramaregeas@chu-bordeaux.fr

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Child

Accepts Healthy Volunteers

No

Sampling Method

Non-Probability Sample

Study Population

As this is a pilot study in a population of premature infants (term bellow 37 weeks of amenorrhea), the projected number of patients included will be 20, based on the department's active patient file, in order to have a minimum of 40 fluid expansion required for the study.

Description

Inclusion Criteria:

  • Premature newborn under 37 weeks of amenorrhea hospitalized in neonatal intensive care
  • Prescription of a 10 to 20ml/kg fluid expansion (crystalloid, blood products or albumin) by the physician in charge, whose goal would be to increase cardiac output (based on clinical, biological and/or echographic criteria).

Exclusion Criteria:

  • Acute cardiogenic pulmonary edema
  • Hemodynamic instability making the delay necessary for abdominal compression and ultrasonography dangerous for the patient
  • Non corrected congenital cardiopathy, or inferior to 15 days postoperative. Intra-abdominal hypertension or painful abdominal palpation
  • Abdominal surgery in the last 15 days
  • Supine position contraindicated or deleterious
  • No investigator available to assess ultrasonographic measures
  • Impairment of echocardiographic acoustic window or restless patient making ultrasonography impossible

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
study of diagnostic accuracy
Patients included in this study would have received fluid expansion in all cases, as the prescription of 10 to 20ml/kg fluid expansion by the physician in charge is the main inclusion criterion.

Study of diagnostic accuracy (non-interventional, prospective, monocentric). Fluid expansion will be delayed for a few minutes while our index test is performed. After fluid expansion, patient will undergo an echocardiographic assessment of response to fluid expansion (gold-standard test). This will allow to test the diagnostic performance of the index test for the "prediction" of fluid responsiveness.

The index test is the ΔSVi-AC: indexed percentage of stroke volume variation between baseline and during a standardized abdominal compression. Stroke volume will be assessed by transthoracic echocardiography.

Patient will undergo 3 echocardiographic assessment: At baseline (stroke volume, cardiac output, left ventricular ejection fraction), During a standardized abdominal compression (stroke volume),After the 10 to 20ml/kg fluid expansion prescribed by the physician in charge (cardiac output).

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value) of the index test (ΔSVi-AC) for the diagnosis of fluid responsiveness,
Time Frame: after abdominal compression, 30 minutes to 4 hours after baseline

Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value) of the index test (ΔSVi-AC) for the diagnosis of fluid responsiveness, defined by an increase of cardiac output > 15% after fluid expansion (ΔCO-FE > 15%, gold-standard test) Index test (ΔSVi-AC) will be calculated as the difference between SV after abdominal compression and SV at baseline, divided by SV at baseline (%). SV will be measured by echocardiographic assessment.

Gold-standard test (ΔCO-FE) will be calculated as the difference between CO after fluid expansion and CO at baseline, divided by CO at baseline (%). CO will be measured by echocardiographic assessment.

value) of the index test (ΔSVi-AC) for the diagnosis of fluid responsiveness, defined by an increase of cardiac output > 15% after fluid expansion (ΔCO-FE > 15%, gold-standard test)

after abdominal compression, 30 minutes to 4 hours after baseline

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Diagnostic accuracy of the SAV mean and the ΔPeak for the diagnosis of fluid responsiveness
Time Frame: after abdominal compression, 30 minutes to 4 hours after baseline

Diagnostic accuracy of the SAV mean and the ΔPeak for the diagnosis of fluid responsiveness, defined by an increase of cardiac output > 15% after fluid expansion (ΔCO-FE > 15%, gold-standard test) in preterm infants.

Comparison of the diagnostic accuracy of these tests.

after abdominal compression, 30 minutes to 4 hours after baseline

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Sophie CRAMAREGEAS, Bordeaux Hospital University

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

January 17, 2024

Primary Completion (Estimated)

November 17, 2024

Study Completion (Estimated)

April 17, 2025

Study Registration Dates

First Submitted

January 18, 2024

First Submitted That Met QC Criteria

February 27, 2024

First Posted (Estimated)

March 1, 2024

Study Record Updates

Last Update Posted (Estimated)

March 1, 2024

Last Update Submitted That Met QC Criteria

February 27, 2024

Last Verified

February 1, 2024

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Premature Baby 26 to 32 Weeks

Clinical Trials on Non interventional study (study of diagnostic accuracy with an extra echocardiographic assessment).

Subscribe